ML20078J883

From kanterella
Jump to navigation Jump to search
Provides 1994 Unit 2 RHR Heat Exchanger Inservice Insp Results
ML20078J883
Person / Time
Site: Braidwood 
Issue date: 11/08/1994
From: Saccomando D
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
References
NUDOCS 9502080282
Download: ML20078J883 (5)


Text

,

Commonwealth Edison M-1400 Opus Place L

Downers Grove.1%nois 60515 November 8, 1994 Office of Nucl,;r Reactor Regulation U.S.' Nuclear Regulatory Commission

. Washington, D.C.

20555 Attention:

Document Control Desk

Subject:

Braidwood Station Unit 2 Flaw Evaluation Report for Residual Heat Removal Heat Exchanger Nozzle to Shell Welds NRC Docket No 50-457

References:

1)

Teleconference between Commonwealth Edison Company and the Nuclear Regulatory Commission dated November 8, 1994, Regarding the Unit 2 RHR Heat Exchanger Nozzle Inspection Results 2)

H. Pontious letter to NRC dated November 8, 1994, transmitting WCAP 13454, " Fracture Mechanics Evaluation Byron and Braidwood Units 1 and 2 Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles" 1

3)

R. Pulsifer letter to T. Kovach dated November 21, 1991, transmitting Safety Evaluation on Flaw Evaluation for Residual Heat Removal Heat Exchanger Nozzle to Shell Welds for Braidwood Unit 2 4

During Braidwood Station's 1994 Unit 2 Refueling Outage (A2R04) a volumetric examination of the Residual Heat Removal (RHR) Heat Exchanger nozzle to shell welds was conducted in accordance with the NRC approved Braidwood Inservice Inspection program.

This examination disclosed indications on the RHR Heat Exchanger which

)

exceed the acceptance criteria as approved by a Safety Evaluation transmitted in reference 3. As a result of the inspection results, several teleconferences were held in which the appropriateness of including the fillet weld in the available wall thickness. During the reference teleconference, Comed committed to providing the Staff with the following documentation to clarify this issue:

1) 1994 Braidwood Unit 2 RHR Heat Exchanger

' Inservice Inspection Results 2)

WCAP 13454, " Fracture Mechanics Evaluation Byron and Braidwood Units 1 and 2 Residual Heat Exchanger Tube Side Inlet and Outlet Nozzles," dated August 1992, and

}$/

91

,1 l

ic 0 e><SF ~\\

9502080282 941108

/

PDR ADOCK 05000457 f'

M O \\$ v-Q PDR

I i

f l

1 e

e 4

b f

(

i t

(

(

{

{

l

.s.

Document Control Desk November 8, 1994 3)

Finite Element Analyses for the Byron and Braidwood Units 1 and 2 RHR Heat Exchanger Nozzle to Shell Welds Attached is item 1.

Item 2 was transmitted in reference 2. Item 3 will be provided to the Staff for their review by November 10, 1994.

Comed believes that the information/ analyses that will be docketed, provides adequate justification that the fillet weld thickness can be credited when performing limit load structural margin assessment of the nozzle to shell weld. Comed understands that this topic may warrant further discussions, and would be happy to address any questions concerning this topic..Please address any questions concerning this correspondence to this office.

Comed appreciates the Staff's efforts towards expedited resolution of this issue.

l 1

Sincerely, tJl$

-e."4 Denise M. Saccomando Nuclear Licensing Administrator.

Attachment cc:

R. Assa, Braidwood Project Manager-NRR

)

S. Dupont, Senior Resident Inspector-Braidwood J. Martin, Regional Administrator-RIII i

Office of Nuclear Safety-IDNS k :nla \\fnad \\ fitre s

m l

Attachment

)

1994 Braidwood Unit 2 Residual Heat Removal (RRR)

Heat Exchanger Inservice Inspection Results

)

K ittla \\ ben $\\ fitre s

The following summarizes, for each nozzle, the recordable i

indications detected during ultrasonic examinations in 1994.

All indications are subsurface flaws, not open to the internal and

.cxternal surfaces.

Both the ultrasonic examinations and visual

  • inspections of the repair cavities points to slag inclusiont i

porosity, and lack of fusion due to fabrication rather than service induced flaws.

Following the methodology of ASME Sectior.

XI, IWA-3310 (b), several flaws have been considered as surface flaws and are so reported in these tables.

The "a/t w/o fillet" column values have been developed using the actual nozzle wall thickness, as measured by ultrasonic examinations.

The "a/t with Fillet" column values have been developed using a conservative effective throat distance based on the location of the indication from the heat exchanger shell wall. Please note that all dimensions are in inches. Due to differences in ultrasonic examination techniqyes the 1991 submitted data is not easily correlatable to the 1994 examination results.

In addition, an independent Level III review and comparison of the 1993 and 1994 automated ultrasonic data did not reveal any evidence of flaw propagation.

l K:nla % d\\fitres

ATTACHMENT

.BRAIDWOOD UNIT 2 RHR HEATER EXCHANGER NO7718 WELD (# EXAM DATA November 8,1994 EFFECTIVE NOZZLE FILLET e/t a/t INO SURFACE /

THICKNESS THROAT W/O WITH 8

e.

LOCATION SUBSURFACE LENGTH o(2a) c/l t

Ic FILLET FILLET 2A RHR HEAT EXCHANGER INLET NOZZLE 1

23 7 to 24 4 Subsurface 0.700

(.160) 0.114 0.390 n/a 21%

n/a 2

9.3 to 10.5 Subsurface 1.200

(.240) 0.100 0.390 n/a 31%

n/a 3

41.1 to 41.7 Subsurface 0.600

(.220) 0.183 0.390 n/a 28 %

n/a 2A RHR HEAT EXCHANGER OUTLET NOZZLE I

18.4 to 18.9 Surfoce 0.500 0.100 0.200 0.365 n/a 27%

n/a 2

19.8 to 23.1 Surfoce 3.300 0.280 0.085 0.365 0.132 77%

56%

3 30 4 to 30.5 Subsurfoce 0.100 (0.030) 0.150 0.365 n/a 4%

n/a 2B RHR HEAT EXCHANGER INLET NOZZLE 1

0 to 0.32 Subsurfoce 0.320

(.180) 0.281 0.394 n/a 23%

n/a 2

0.76 to 1.20 Subsurfoce 0440

( 440) 0 500 0 394 n/a 56%

n/a 3

4.9 to 5.7 Surface 0.800 0.300 0.375 0.394 0.132 76%

57%

4 8.4 to 9.9 Surfoce 1.500 0.240 0.160 0.394 0.132 61%

46%

5 8.4 to 9.8 Subsurfoce 1.400

( 080) 0.029 0394 n/a 10%

n/a 6

13.2 to 14 6 Subsurface 1.400

( 060) 0.021 0.394 n/a 8%

n/o 7

15 0 to 15.1 Subsurface 0.100 C.040) 0.200 G3194 n/a 5%

n/o 8

16.2 to 16.3 Subsurfoce 0.100

(.030) 0.150 0394 n/a 4%

n/a 9

23 0 to 23 2 Subsurface 0.200

(.160) 0.400 0.394 n/a 20%

n/a 10 25 4 to 25 5 Subsurface 0.100

(.040) 0.200 0.394 n/a 5%

n/a 11 29.1 to 29.5 Subsurface 0.400

(.100) 0.125 0.394 n/o 13%

n/a 12 36 0 to 36.3 Subsurfoce 0.300

(.080) 0.133 0.394 n/a 10E n/a 13 41.7 to 41.75 Subsurface 0.050

(.020) 0.200 0.394 n/a 3%

n/a 14 42.3 to 42.4 Subsurface 0.100

(.060) 0.300 0.394 n/a 8%

n/a 15 44 6 to 44 7 Subsurface 0.100

(.140) 0.700 0.394 n/a 18%

n/a 2B RHR HEAT EXCHANGER OUTLET NOZZLE 1

0 to 1.9 Surfoce 1.900 0.500 0.263 0.385 n/a 130%

Removed 2

2 5 to 2 8 Subsurface 0.300 (0.140) 0.233 0.385 n/a 18%

n/a 3

3 2 to 3 25 Subsurface 0.050

(.040) 0.400 0.385 n/a 5%

n/a 4

4 0 to 4 2 Subsurface 0.200

(.120) 0.300 0.385 n/o 16%

n/o 5

5 0 to 9.9 Surface 4 900 0 440 0.090 0.385 n/a 114*.

Removed 6

131 to 13.5 Subsurface 0.400

(.180) 0.225 0.385 n/a 23%

n/a 7

216 to 23 6 Subsurfoce 2.000

(.240) 0.060 0.385 n/a 31%

Removed 8

24 6 to 25.0 Subsurface 0400

(.060) 0.075 0.385 n/a 8%

n/a 9

26 3 to 26 4 Subsurface 0.100

(.030) 0.150 0.385 n/a 4%

n/a 10 27 0 to 27.1 Subsurface 0.100

(.030) 0.150 0.385 n/o 4%

n/a 11 28 3 to 28 4 Subsurface 0.100

(.030) 0.150 0.385 n/a 4%

n/a 12 30.1 to 30 2 Subsurface 0.100

(.040) 0.200 0.385 n/a 5%

n/a l

13 32 3 to 32 9 Subsurfoce 0600

(.180) 0.150 0.385 n/a 23%

n/a 14 3531o38.7 Subsurfoce 3 400

( 480) 0.071 0.385 n/a 62%

Removed 15 415 to 41.6 Subsurfoce 0.100

(.120) 0.600 0.385 n/a 16%

n/a 16 42.2 to 44 6 Subsurface 2 400

(.440) 0.092 0.385 r./o 57%

Removed j

-