Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20083J919 + (10:38:56, 14 December 2024)
- ML20083J917 + (10:38:57, 14 December 2024)
- ML20083J918 + (10:38:57, 14 December 2024)
- BSEP-83-3859, Responds to NRC Re Violations Noted in IE Insp Repts 50-324/83-32 & 50-325/83-32.Corrective actions:real- Time Training Provided to Operating Shift Personnel Re Operating Instruction OI-13 + (10:38:58, 14 December 2024)
- Press Release-II-20-003, NRC Schedules Virtual Meeting to Discuss Performance of Urenco USA Facility + (10:38:58, 14 December 2024)
- BSEP-83-3890, Suppls 830608 Response to IE Bulletin 83-03 Re Check Valve Failures in Raw Water Cooling Sys of Diesel Generators. Periodic Testing of Valves Incorporated Into Procedure MI-10-521I.Initial Insps Completed 831113.Item Closed + (10:38:59, 14 December 2024)
- ML20083J903 + (10:38:59, 14 December 2024)
- 05000261/LER-1983-031-03, /03L-0:on 831130,two Containment Isolation Valves Failed to Close on Phase a Isolation Test & Fire Protection Valve FP-258,waste Disposal Valve WD-1728 & Second Valve Did Not Properly Isolate + (10:39:01, 14 December 2024)
- ML20083J890 + (10:39:02, 14 December 2024)
- 3F1283-18, Responds to 831129 Request for Addl Info on IE Bulletin 80-11, Masonry Wall Design. Requested Info Will Be Provided by 840229 + (10:39:03, 14 December 2024)
- ML20083J885 + (10:39:03, 14 December 2024)
- 05000331/LER-1983-043-03, /03L-0:on 831128,while Performing Daily Instrument Test,Torus B Level Transmitter Functioned Erratically.Caused by Corrosion & Dirt Building on Internal Amphenol Connector. Transmitter Cleaned & Recalibr + (10:39:05, 14 December 2024)
- ML20083J878 + (10:39:06, 14 December 2024)
- ML20083J876 + (10:39:06, 14 December 2024)
- 05000336/LER-1983-031-01, /01T-0:on 831222,discovered That Schedule 40 Vs Std Wall Pipe Installed in Portions of Svc Water Sys.Caused by Matl Unavailability.Stress Analysis Updated & Four Hangers Modified + (10:39:08, 14 December 2024)
- ML20083J873 + (10:39:09, 14 December 2024)
- ML20083J872 + (10:39:09, 14 December 2024)
- TXX-4092, Provides Addl Details & Clarifications to Re High/Moderate Energy Pipe Break Analysis.Local Control Station Relocated to Prevent Damage from Flooding.All High Energy Lines Designed to Seismic Category 1 Requirements + (10:39:10, 14 December 2024)
- ML20083J866 + (10:39:11, 14 December 2024)
- ML20083J867 + (10:39:11, 14 December 2024)
- ML20083J863 + (10:39:12, 14 December 2024)
- 05000331/LER-1983-044-03, /03L-0:on 831128,during Normal Operation, Surveillance Test of Containment Atmosphere Dilution Sys Revealed Pressure Regulator PCV-4323A & B Malfunctions. Caused by Worn O-rings & Seats + (10:39:14, 14 December 2024)
- ML20083J853 + (10:39:15, 14 December 2024)
- 05000315/LER-1983-121-01, /01T-0:on 831219,discovered That Continuous Charcoal & Particulate Samples Not Obtained.Caused by Inadequate Procedures.Auxiliary Sampling Equipment Utilized + (10:39:17, 14 December 2024)
- 05000254/LER-1983-046-03, /03L-0:on 831128,RHR Svc Water Pump 1C Taken Out of Svc.Caused by Leakage of Teflon Seal Ring.Thicker Ring Fabricated & Installed.Leakage Eliminated + (10:39:18, 14 December 2024)
- ML20083J850 + (10:39:19, 14 December 2024)
- ML20083J849 + (10:39:20, 14 December 2024)
- 05000267/LER-1983-050-03, Pcrv CWS Temp Scanner Surveillance Not Performed within Required Interval.Caused by Personnel Error.Personnel Reminded of Duties.Test Completed on 831121 + (10:39:22, 14 December 2024)
- AECM-84-0002, Forwards Response to 831212 Request for Info Re Plant Staffing & Experience.Experience of Personnel During Const & Preoperational Phases Offset Lack of BWR Operating Experience + (10:39:23, 14 December 2024)
- ML20083J844 + (10:39:23, 14 December 2024)
- 05000395/LER-1983-137-03, /03L-0:on 831212,boric Acid Tank Level Indicator Found Out of Calibr.Caused by Instrument Drift.Transmitter Calibr.No Addl Corrective Action Other than Preventive Maint & Testing Required + (10:39:25, 14 December 2024)
- 05000282/LER-1983-033-01, /01T-0:on 831208,isolation Valve CV-31440 in Nitrogen Supply to Accumulators Exhibited Excessive Leakage. Caused by Plug to Cage Galling,Preventing Full Valve Closure.Plug,Cage & Seat Replaced + (10:39:27, 14 December 2024)
- ML20083J833 + (10:39:28, 14 December 2024)
- ML20083J829 + (10:39:28, 14 December 2024)
- ML20083J827 + (10:39:29, 14 December 2024)
- 05000325/LER-1983-055-03, /03L-0:on 831129,reactor Water Sample Outboard Primary Containment Isolation Valve B32-F020 Discovered Not Fully Closed W/Valve Pneumatic Operator.Caused by Actuator Spring Out of Adjustment.Spring Replaced + (10:39:30, 14 December 2024)
- 05000373/LER-1983-150-01, /01T-0:on 831212,Trip Function 3.a & 4.a for Detector Not Full in Test Not Performed.Caused by Faulty Technique to Identify Requirements.New Procedures Will Be Written to Satisfy Requirements + (10:39:35, 14 December 2024)
- ML20083J824 + (10:39:36, 14 December 2024)
- ML20083J815 + (10:39:37, 14 December 2024)
- ML20083J817 + (10:39:37, 14 December 2024)
- 05000265/LER-1983-023-03, /03L-0:on 831128,during Main Steam Line High Flow Calibr Qis 21-1,pressure Switch DPIS 2-261-2K Found to Trip at 148.5 Psid.Caused by Instrument Setpoint Drift.Instrument Recalibr + (10:39:39, 14 December 2024)
- ML20083J804 + (10:39:40, 14 December 2024)
- ML20083J801 + (10:39:41, 14 December 2024)
- ML20083J802 + (10:39:41, 14 December 2024)
- FVY-83-125, Responds to NRC Re Violations Noted in IE Insp Rept 50-271/83-29.Corrective Actions Withheld (Ref 10CFR73.21) + (10:39:42, 14 December 2024)
- ML20083J799 + (10:39:42, 14 December 2024)
- ML20083J793 + (10:39:43, 14 December 2024)
- 05000327/LER-1983-175-03, /03L-0:on 831124,refueling Water Storage Tank Level Channel Found Out of Tech Spec Tolerance.Caused by Instrument Drift.Transmitter Recalibr + (10:39:44, 14 December 2024)
- ML20083J788 + (10:39:45, 14 December 2024)
- ML20083J786 + (10:39:46, 14 December 2024)
- IR 05000454/1983057 + (10:39:48, 14 December 2024)