-ms THE CINCINNATI GAS & ELECTRIC COMPANY M
CINCINN ATI. OHIO 45201 December 28, 1983 LOZ-83-0161 J. WILLI AM S, JR semos vics PatssorNT NUCLE AR OPERATIONS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention:
Mr. J.G. Keppler Regional Administrator Gentlemen:
RE:
WM. H. ZIMMER NUCLEAR POWER STATION - UNIT 1 IE BULIETIN 83-06, NONCONFORMING MATERIALS SUPPLIED BY TUBE-LINE CORPORATION FACILITIES AT LONG ISLAND CITY, NEW YORK; HOUSTON, TEXAS; AND CAROL STREAM, ILLINOIS W.O.
57300, JOB E-5590, FILE NO. 956C, This letter is in response to I.E.Bulletin 83-06 concerning nonconforming materials supplied by Tube-Line Corporation Facilities at Long Island, New York; Houston, Texas; and Carol Stream, Illinois.
A review of purchasing documentation and subsequent investigation of suppliers and subvendors, determined that CG&E did not receive any Tube-Line material for use in safety related systems at Zimmer Nuclear Power Station.
I.E.Bulletin 83-06 is therefore not applicable to this facility.
In accord with your request to provide the following information, we advise that approximately 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br /> were expended inthe review and preparation of this response.
There was no radiation exposure associated with the investigation.
~_
8401050419 831228 PDR ADOCK 05000358 G
PDR Thb g
ifE1Lil'\\o
ka t
Mr. J.G. Keppler Regional Administrator December 28, 1983 LOZ-83-0161 Page 2 We trust this will complete our responsibility in responding to I.E.Bulletin 83-06.
Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By
. 206
~
~
. IfYLLIAPIf,' J SENIOR VICE P SIDENT DJB/sfr cc:
NRC Office of Inspection & Enforcement Washington, D.C.
20555 NRC Resident Site Supervisor ATTN:
W.M. Hill, Jr.
NRC Zimmer Project Inspector, Region III ATTN:
E. R. Schweibinz U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.