- 05000267/LER-1976-025, :on 760803,primary Closure Leak Rate for Circular 1C Penetration Exceeded Limits.Cause Unknown.Investigation Underway + (07:56:17, 14 December 2024)
- ML20085N493 + (07:56:18, 14 December 2024)
- ML20085N484 + (07:56:19, 14 December 2024)
- ML20085N481 + (07:56:19, 14 December 2024)
- ML20085N476 + (07:56:20, 14 December 2024)
- ML20085N470 + (07:56:21, 14 December 2024)
- ML20085N468 + (07:56:22, 14 December 2024)
- ML20085N467 + (07:56:22, 14 December 2024)
- ML20085N466 + (07:56:23, 14 December 2024)
- 05000267/LER-1976-027, :on 760827,circulator 1B Tripped on Apparent Loss of Bearing Water.Caused by Dry Water Surge Tank Low Level Trip Switch Actuation.Const Workmen May Have Inadvertently Actuated Switch + (07:56:24, 14 December 2024)
- 05000267/LER-1976-028, A:On 760920,reactor Bldg Sump Pump Started Automatically During rise-to-power Test.Caused by Operator/ Procedure Error.Step of Dual Purpose Surveillance Test Incorrectly Performed.Procedure Revised + (07:56:26, 14 December 2024)
- 05000267/LER-1976-029, :on 761004,fire Pump Engine Showed Signs of Overheating During Surveillance Test.Caused by Shorted Solenoid Valve Coil.Valve Removed as Unnecessary + (07:56:28, 14 December 2024)
- ML20085N455 + (07:56:29, 14 December 2024)
- 05000267/LER-1976-030, :on 761010,standby Generator 1B Engines Tripped Due to High Temps.Caused by Fouled HX Jackets.Hxs Cleaned + (07:56:31, 14 December 2024)
- 05000267/LER-1976-031, :on 761028,valve Failed to Close Automatically. Caused by Burned Coils on Valve Solenoids.Solenoids Replaced & Subsequently Burned Out.Investigation Underway + (07:56:33, 14 December 2024)
- ML20085N441 + (07:56:34, 14 December 2024)
- ML20085N436 + (07:56:35, 14 December 2024)
- ML20085N420 + (07:56:36, 14 December 2024)
- 05000267/LER-1976-032, :on 761030,steam Outlet Block Valve Fuse Would Not Shut After Circulation Transferred to Water Drive.Caused by Stuck Solenoid Valves on Hydraulic Sys.Solenoids Changed on Eight Valves + (07:56:38, 14 December 2024)
- ML20085N406 + (07:56:41, 14 December 2024)
- 05000368/LER-1991-017-01, :on 911011,discovered That TS Surveillance Test for Station Batteries Not Performed within Max Allowable Time Limit.Caused by Lack of Oversight of Surveillance Activity.Tests Highlighted on Shop Schedule + (07:56:43, 14 December 2024)
- ML20085N402 + (07:56:44, 14 December 2024)
- ML20085N396 + (07:56:45, 14 December 2024)
- ML20085N400 + (07:56:45, 14 December 2024)
- ML20085N393 + (07:56:46, 14 December 2024)
- ML20085N384 + (07:56:46, 14 December 2024)
- ML20085N382 + (07:56:47, 14 December 2024)
- SNRC-1860, Informs of Plans to Continue Using NRC Approved Plans Entitled Snps Security Training... W/Rev Through 900918 & Snps Safeguards... W/Revs Through 880513,per 911104 Request for Exemption from 10CFR73.55 + (07:56:47, 14 December 2024)
- 05000219/LER-1991-006, :on 910924,check Revealed Degradation in Flow Dampening Snubber Performance for Seven of Eight Sensors. Caused by Inadequate Design Control.Snubbers Removed from Pipe Break Sensors + (07:56:49, 14 December 2024)
- ML20085N378 + (07:56:50, 14 December 2024)
- ML20085N375 + (07:56:50, 14 December 2024)
- NLS9100717, Suppls Proposed Change 88 to License DPR-46,revising Spec 5.2.B Re Control Rod Absorber Matl,Dtd 910423,per NRC Request + (07:56:51, 14 December 2024)
- ML20085N370 + (07:56:52, 14 December 2024)
- ML20085N368 + (07:56:52, 14 December 2024)
- ML20085N365 + (07:56:53, 14 December 2024)
- 05000440/LER-1991-022, :on 911011,while Manipulating Front Panel Switches on Drywell Atmospheric Gaseous Monitor,Radiation Monitor Indication Spiked Upscale.Caused by Unrecognized Equipment Characteristics.Info Tag Attached to Monitor + (07:56:55, 14 December 2024)
- ML20085N356 + (07:56:56, 14 December 2024)
- 05000440/LER-1991-021, :on 911011,preferred Source Breaker Would Not Close on Demand from Switch on Control Room Panel Since 910904.Caused by Equipment Malfunction.Spring Pins on Tooling Racks Will Be Shortened & Instruction Revised + (07:56:58, 14 December 2024)
- PY-CEI-NRR-1414, Forwards LERs 91-021-00 & 91-022-00 + (07:56:58, 14 December 2024)
- ML20085N351 + (07:57:00, 14 December 2024)
- 05000302/LER-1991-009, :on 911008,discovered That Relays & Fuses Located in Control Relay Cabinets in EDG Rooms May Exceed Design Ambient Temp Rating.Caused by Proximity of Cabinets to Edg.Fuses Will Be Replaced + (07:57:05, 14 December 2024)
- 05000313/LER-1991-010-03, :on 911005,discovered That Offsite Power Source May Be Unable to Maintain Adequate Voltage to Safety Loads During Accident Conditions.Caused by Increased Offsite Grid Loading.Procedural Guidance Implemented + (07:57:07, 14 December 2024)
- HL-1916, Special Rept 1-91-008:on 911014,four Suppression Sys Flooding Valves in Fixed Water Suppression Sys Not Surveilled Once Per 18 Months.Caused by Less than Adequate Procedure.Valves Tested & Inspected Per Revised Procedures + (07:57:08, 14 December 2024)
- HL-1902, Forwards Results of Insp of IGSCC in Susceptible Welds, Performed During Current Refueling Outage,Per Generic Ltr 88-01 & Rev 2 to NUREG-0313.New crack-like Indications Noted in One 28 Category C Weld + (07:57:09, 14 December 2024)
- ML20085N344 + (07:57:09, 14 December 2024)
- 05000361/LER-1991-016-01, :on 911010,control Room Isolation Sys,Train B, Spurious Actuation Occurred.Caused by Momentary Instrument Failure of Train B Particulate/Iodine Channel.Filtering Circuit Added to Ac Input to Monitor Module + (07:57:11, 14 December 2024)
- ML20085N325 + (07:57:12, 14 December 2024)
- 05000482/LER-1991-019, :on 911011,broken Fuel Rod Discovered in Fuel Assembly F31 Located in Core Position L-9 During Fuel off-loading Operations.Caused by grid-to-rod Fretting.New Core Loading Design Pattern Developed + (07:57:14, 14 December 2024)
- ML20085N308 + (07:57:15, 14 December 2024)
- ML20085N315 + (07:57:15, 14 December 2024)
- ML20085N287 + (07:57:16, 14 December 2024)
- ML20085N291 + (07:57:16, 14 December 2024)