Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20090E176 + (18:23:14, 13 December 2024)
- ML20090E175 + (18:23:14, 13 December 2024)
- ML20090E174 + (18:23:15, 13 December 2024)
- ML20090E170 + (18:23:16, 13 December 2024)
- ML20090E173 + (18:23:16, 13 December 2024)
- ML20090E167 + (18:23:17, 13 December 2024)
- ML20090E168 + (18:23:17, 13 December 2024)
- ML20090E166 + (18:23:18, 13 December 2024)
- ML20090E165 + (18:23:19, 13 December 2024)
- ML20090E164 + (18:23:20, 13 December 2024)
- ML20090E163 + (18:23:21, 13 December 2024)
- ML20090E159 + (18:23:22, 13 December 2024)
- ML20090E161 + (18:23:22, 13 December 2024)
- ML20090E157 + (18:23:23, 13 December 2024)
- ML20090E158 + (18:23:23, 13 December 2024)
- ML20090E155 + (18:23:24, 13 December 2024)
- ML20090E149 + (18:23:25, 13 December 2024)
- ML20090E140 + (18:23:25, 13 December 2024)
- 05000220/LER-1975-001, :on 750109,level Control Valve to Emergency Condensers Failed,Resulting in High Water Level Alarm.Caused by Inability to Close Valve.Level Maintained W/Manual Valve. Spare Controller Installed + (18:23:27, 13 December 2024)
- ML20090E137 + (18:23:28, 13 December 2024)
- 05000220/LER-1975-004, :on 750212,during Plant Startup,Feedwater Pump 12 Failed to Start.Caused by Broken Linkage on Suction Pressure Switch Due to Vibration.Switch Linkage Replaced + (18:23:30, 13 December 2024)
- ML20090E126 + (18:23:31, 13 December 2024)
- ML20090E125 + (18:23:32, 13 December 2024)
- ML20090E124 + (18:23:32, 13 December 2024)
- 05000220/LER-1975-003, :on 750212,during Plant Startup,Waste Evaporator Concentrator Failed,Resulting in Leakage.Caused by Sulfuric Acid Contamination + (18:23:34, 13 December 2024)
- ML20090E113 + (18:23:35, 13 December 2024)
- ML20090E108 + (18:23:36, 13 December 2024)
- ML20090E101 + (18:23:37, 13 December 2024)
- ML20090E104 + (18:23:37, 13 December 2024)
- ML20090E099 + (18:23:38, 13 December 2024)
- ML20090E098 + (18:23:39, 13 December 2024)
- ML20090E097 + (18:23:39, 13 December 2024)
- ML20090E095 + (18:23:40, 13 December 2024)
- ML20090E088 + (18:23:41, 13 December 2024)
- ML20090E082 + (18:23:42, 13 December 2024)
- ML20090E074 + (18:23:42, 13 December 2024)
- ELV-03417, Submits Addl Info Re 911118 Application for Amends to Licenses NPF-68 & NPF-81,changing TS 3.4.4 & 3.4.9.3 Re Relief Valves & Cold Overpressure Protection Sys, Respectively + (18:23:43, 13 December 2024)
- ML20090E068 + (18:23:43, 13 December 2024)
- PMNS20200324, Meeting with Nuclear Industry to Discuss COVID-19 Regulatory Impacts with Respect to 10 CFR Part 26 and Recently Issued Letter Regarding the Exemption Process + (18:23:44, 13 December 2024)
- ML20090E048 + (18:23:46, 13 December 2024)
- A10185, Responds to NRC Re Violations Noted in Insp Rept 50-336/92-03 on 920107-10.Corrective Actions:Change to TS 4.7.6.1 Will Be Proposed to Replace Wording Operating W/ Word Aligned to Ensure Proper Sys Alignment + (18:23:47, 13 December 2024)
- ML20090E045 + (18:23:47, 13 December 2024)
- ML20090E041 + (18:23:48, 13 December 2024)
- ML20090E037 + (18:23:49, 13 December 2024)
- 05000220/LER-1975-005, :on 750401,during Testing of Emergency Ventilation Sys,Reactor Protection Sys Solenoid Valve SN-831630 Failed to Open.Caused by Broken Stem & Metal Oxide Buildup.Valves Repaired + (18:23:54, 13 December 2024)
- ELV-03478, Special Rept 2-92-1:on 920205,DG 2B Declared Inoperable Due to Negative Reactive Power.Cause Undetermined.Engine Being Tested Each Wk While Monitoring Equipment Connected to Capture Any Info Useful in Investigation of Cause + (18:23:55, 13 December 2024)
- 05000220/LER-1975-006, :on 750405,during Surveillance testing,RE-18A Reactor Level lo-lo-lo Found Actuating at 131 Rather than 128.5 Inches of Water.Caused by Instrument Drift.Instrument Recalibr + (18:23:57, 13 December 2024)
- 05000220/LER-1975-007, :on 750412,during Quarterly Testing,Ec IV 11 (AC) Failed to Open.Caused by Loose Connection in Remote Manual Wiring Terminal Block.Connection Tightened + (18:23:59, 13 December 2024)
- 05000220/LER-1975-008, :on 750414,during Normal Operation,Relay Coil in Reactor Protection Sys Relay 12K30 Shorted.Caused by Environ & High Usage.Coil Replaced + (18:24:02, 13 December 2024)
- 05000220/LER-1975-009, :on 750414,during Function Test,Average Power Range Monitor 11 Failed to Provide High Alarm.Caused by Open Transistor in Dual Alarm Unit.Transistor Replaced + (18:24:08, 13 December 2024)