,.g q

Li Public Senace Electnc and Gas Company 80 Park Plaza, Newark, NJ 07101/ 201430-8217 MAILING ADDRESS / P.O. Box 570, Newark, NJ 07101

- Robert L. Mitti General Manager Nuc! ear Assuranca and Reguladon July 9, 1984 Director (

Nuclear Reactor Regulation U.S.

Nuclear Regulatory. Commission 7920 Norfolk Avenue Bethesda, MD 20814 Attention:

-Mr.

Albert Schwencer, Chief Licensing Branch 2 Division of Licensing Gentlemen:

HOPE CREEK GENERATING STATION DOCKET NO. 50-354 CONTROL. ROOM HABITABILITY - DOSE ASSESSMENT INFORMATION

~ On A'pril 10, 1984, a. meeting was held in the Bethesda, Maryland of fices of the NRC. to discuss control room habit-abili.ty at the Hope Creek Generating Station.

In DSER, Section 6.4, information was requested which would. enable the staff to perform a control room X/O analysis using the Murphy-Campe methodology.

.In. response to the staf f's request at the April 10,.1984, meeting, advance copies of new FSAR Table 6.4-5 and updated FSAR Figure 6.4-2 are attached for information in support of the staff's analysis.

This information will be incorporated in an upcoming amendment to the HCGS FS AR.

We understand that, upon receipt of this information, the staff will perform a Murphy-Campe X/O analysis to assess compliance with General Design Criteria 19.

Should you have any questions in this regard, please contact us.

Very truly yours,

/

fo k

7 A

fd

-Attachment i

I The Energy' People 954912 (3W 4 84 L-

ET.-.

1 3

4,.. ~

+

Director of Nuclear

~

- Reactor Regulation:

. 2-7/9/84 kC

-D.

H.-Wagner

,USNRC-Licensing Project Manager

- Mr.-W. H.... Ba tema n

.USNRC Senior Resident Inspector T

?

h

'DN17[ 1/. 2 -

t y

a d

g I'

4 1.

2.'.

r-Y F

i.

d m

.'H,

).

2

{l-l

-cy p.

~-

ps

cy

~

HCGS FSAR TABLE 6.4-5

-4

+

' RADIOACTIVE RELEASE LOCATIONS A.

. RELATIVE TO CONTROL ROOM INTAKE s

DISTANCE FROM CONTROL ROOM INTAKE TO RELEASE (ft) 5 RECEPTOR /;

ELEVATION X

Y

' RELEASE' POINT.

OF -(ft)

(NORTH / SOUTH)

(EAST / WEST) l1.. - Control-' Room ' Int.ake.-

-156'-9" O'

0'

'. 2.

FRVS 'L Exhaus t. Vent (a) 301'-4" lll'-2"(S) 129'-0"(E)

3.f South PlantiVent (b) 217'-0" lll'-2"(S) 303'-3"(E)

"4 7 North Plant Vent 217'-0" 266'-1"(N) 306'-3"(E) 5.c ' Reactor-Building

'143'-9" 111'-2"(S) 45'-0"(E)

' Blowout-Panel-6.

MSl TunnelDNorth(c) 161'-11" 94'-2"(S) 226'-2"(E)

-Blowout Panel

- ( Eme rge ncy ) ~

17. :

MS. Tunnel South 162'-0" 137'-5"(S) 224'-ll"(E)

Blowout Panel

( Eme rgency ).

'8..-MS Tunnel-: Blowout

-143'-6" 151'-2"(S) 274'-6"(E)

Panel-r Design Basis Accident (s) associated with release locations (per Chapter 15.0

. analyse s) : -

LOCA, Fuel Handling Accident

" f.

Waste' Gas System Failure, Control Rod Drop, Instrument Line Break

~

Steam Line. Break RSCraz-MP84 112:08i 01-a z S'

m.

.s

l I

t.

~{

~

syt:'m( Ppultf W AS Mr.M i

g ws

... _a

..__.___a g

M

~,

__..___4

___.____s M DM bl48 lig 4ftaA6L d

s M4 Prf r

ADMIN.

j en G m.,

~~

G Eu7 i

JM!YMMMf7(b m m

    • p jf wQ=l AW var nox

. < r w rv"a r koor r

p l

.,u avutr No.I fh86 L.

L. [1 tw#stuMFS j y a

t P awer n o Mao

^/

s W

asume 7

s.rurin

-~-

m N gJ @

l J

'~*

g WAN Q

$pt r

. -.. _ _ m, K ^ *^

  • 6 6*s

% cos **xt I

~

I L,,,a ~IT9V,st4

--e-D

,g, Yh EIk'.'u%

s,.

s M,

V s,

%!,45 !

j Y hl E N oca a4e r

s Ncanaset.1% sistmge Whh WIWA10WFW YYW 1

l

~

N60 leM62f-T~

MN ouT50 A't NTAtts, r.

/

cm S(

%*, se st.

g.g, ode MLtet stoom

' **'/

s.

SK A 1006, REV N "

g/

/ -. _ ' n t'- ' 020 )

.AIOPE CMEEK

' 4 ("

CN hl GENERATING STATION r

j

" ' S* *' 5"

"")

riNat SAFETY ANALYSIS REPORT

-}

av j

g

/

StcT. A.A PLANT LAYOUT WITH RESPECT TO CONTROL ROOM INTAKE FIGURE 6.4 2

.~m N

nyz:,

t g

O h.

3 O

d l ibt k 1

0 i

i l

'J I

,, s Ibi g

i s

[H-i

@u g,

i i

h$( h O

l-y *s l

l 5

l p 4

.d l !!

ih Hl h*

l l

l a

N_

g-f._

h l

l l

l i

z W

i l

g i

i hm i

i 1

i i

I k

i I

l N

l i

n' N

e i

..s..

g m

{

l 1a

,4%

?_

,i 3x

=

p h... t

.i e

a n

fh$ b El $b g

w O

t

.....--...---------;---_-----'