Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000413/LER-1984-002-04, :on 840728,computer Software Problem Discovered During Analysis of Concentration of Radioactive Matl in Waste Monitor Tank Liquids.Cause Not Stated.Software Problem Corrected + (13:04:08, 13 December 2024)
- 05000416/LER-1984-036, :on 840727,channels a & B of Reactor Water Cleanup Sys Differential Flow Isolation Trip Found to Exceed Tech Spec Setpoint Limits.Caused by Change in Calibr Data. Surveillance Will Be Completed by Startup + (13:04:10, 13 December 2024)
- U-602537, Forwards Reissued NPDES Permit for Clinton Power Station + (13:04:11, 13 December 2024)
- 05000277/LER-1984-016, :on 840727,liquid Penetration Exams of Reactor Pressure Vessel Jet Pump Inlet Riser Safe Ends Revealed crack-like Indications.Caused by Igscc.Addl Radiographic & Liquid Dye Penetrant Exams Will Be Performed + (13:04:13, 13 December 2024)
- ML20096C855 + (13:04:14, 13 December 2024)
- ML20096C848 + (13:04:15, 13 December 2024)
- ML20096C849 + (13:04:15, 13 December 2024)
- 05000346/LER-1984-005, :on 840507,both Control Room Emergency Ventilation Chiller Control Power Switches Found in Off Position.Caused by Personnel Error.Labels Placed Above Switches for Clear Identification + (13:04:18, 13 December 2024)
- ML20096C842 + (13:04:19, 13 December 2024)
- ML20096C843 + (13:04:19, 13 December 2024)
- 05000412/LER-1992-005-01, :on 920409,sound of Air Flow in East Cable Vault Room Heard & Temporary Seal on Spare Electrical Penetration Leaking Air Out of Containment.Caused by Procedure Deficiency.Cabling Removed + (13:04:21, 13 December 2024)
- ML20096C836 + (13:04:22, 13 December 2024)
- ML20096C831 + (13:04:23, 13 December 2024)
- ML20096C829 + (13:04:24, 13 December 2024)
- ML20096C828 + (13:04:24, 13 December 2024)
- 05000265/LER-1992-009-03, :on 920327,RHR Sys Pumps 2C & 2D Autostarted During Relay 10A-K17B Testing.Caused by Personnel Using Incorrect Work Package Instructions to Direct Placement of Jumper.Work Package Revised + (13:04:27, 13 December 2024)
- ML20096C821 + (13:04:29, 13 December 2024)
- ML20096C813 + (13:04:30, 13 December 2024)
- ML20096C808 + (13:04:30, 13 December 2024)
- ML20096C806 + (13:04:34, 13 December 2024)
- ML20096C805 + (13:04:35, 13 December 2024)
- ML20096C803 + (13:04:35, 13 December 2024)
- ML20096C797 + (13:04:36, 13 December 2024)
- ML20096C794 + (13:04:37, 13 December 2024)
- ML20096C796 + (13:04:37, 13 December 2024)
- LIC-96-0004, Monthly Operating Rept for Dec 1995 for Fort Calhoun Station + (13:04:38, 13 December 2024)
- ML20096C787 + (13:04:39, 13 December 2024)
- ML20096C791 + (13:04:39, 13 December 2024)
- ML20096C784 + (13:04:40, 13 December 2024)
- BVY-92-053, Monthly Operating Rept for Apr 1992 for Vermont Yankee Nuclear Power Station + (13:04:41, 13 December 2024)
- ML20096C781 + (13:04:41, 13 December 2024)
- ML20096C774 + (13:04:42, 13 December 2024)
- ML20096C765 + (13:04:43, 13 December 2024)
- ML20096C773 + (13:04:43, 13 December 2024)
- ML20096C761 + (13:04:44, 13 December 2024)
- ML20096C741 + (13:04:45, 13 December 2024)
- ML20096C758 + (13:04:45, 13 December 2024)
- ML20096C738 + (13:04:46, 13 December 2024)
- ML20096C737 + (13:04:47, 13 December 2024)
- 05000339/LER-1992-012, :on 920419,2H 4160-volt Emergency Bus Became de-energized During Response Time Testing of Circuitry & SW Flow to Component Cooling HX Was Lost Momentarily.Bus Was re-energized & SW Flow Was Restored + (13:04:48, 13 December 2024)
- ML20096C733 + (13:04:49, 13 December 2024)
- ML20096C732 + (13:04:50, 13 December 2024)
- 05000333/LER-1995-015-01, :on 951215,discovered Omission of RWR Seal Purge Flow from Reactor Heat Balance.Caused by Inadequacy in Original Plant Design.Restricted Plant Output to 2434 Mwt to Maintain More than 1.4 Mwt Margin + (13:04:52, 13 December 2024)
- ML20096C716 + (13:04:53, 13 December 2024)
- ML20096C726 + (13:04:53, 13 December 2024)
- ML20096C714 + (13:04:58, 13 December 2024)
- ML20096C713 + (13:04:58, 13 December 2024)
- ML20096C709 + (13:04:59, 13 December 2024)
- ML20096C706 + (13:05:00, 13 December 2024)
- ML20096C705 + (13:05:00, 13 December 2024)
- ML20096C704 + (13:05:01, 13 December 2024)