- AECM-84-0444, Responds to NRC Re Violations Noted in Insp Rept 50-416/84-23.Denies Violation Due to Documented Safety Evaluation & Nonconformance at Time of Implementation of Change & 1-wk Advance Notice of Action + (10:59:27, 13 December 2024)
- 05000331/LER-1984-038, :Between 841029-1115,two Secondary Containment Airlock Doors Simultaneously Opened Three Times.Caused by Defective Door Latch Mechanisms or Interlock Solenoids. Devices Repaired + (10:59:29, 13 December 2024)
- ML20100E427 + (10:59:30, 13 December 2024)
- ML20100E426 + (10:59:31, 13 December 2024)
- ML20100E425 + (10:59:32, 13 December 2024)
- ML20100E424 + (10:59:32, 13 December 2024)
- ML20100E407 + (10:59:34, 13 December 2024)
- ML20100E401 + (10:59:35, 13 December 2024)
- ML20100E383 + (10:59:35, 13 December 2024)
- RBG-19600, Submits Addl Info Re Surveillance of ESF Unit Coolers,In Response to NRC Request Per SER Confirmatory Item 30.ESF Unit Coolers Will Be Added to Operations Daily Log & Operator Will Verify Unit Cooler Operation + (10:59:36, 13 December 2024)
- ML20100E354 + (10:59:37, 13 December 2024)
- ML20100E340 + (10:59:38, 13 December 2024)
- ML20100E335 + (10:59:38, 13 December 2024)
- ML20100E334 + (10:59:39, 13 December 2024)
- ML20100E332 + (10:59:40, 13 December 2024)
- 05000281/LER-1984-015-01, :on 841029,main Feedpump a Tripped as Result of Load Shedding Leading to Low Steam Generator Level & Reactor Trip.Caused by Inadequate Procedures.Operating Procedures Will Be Revised + (10:59:42, 13 December 2024)
- ML20100E325 + (10:59:44, 13 December 2024)
- ML20100E299 + (10:59:44, 13 December 2024)
- 05000352/LER-1984-001-01, :on 841027,channel Checks of Four Scram Discharge Vol Level Transmitters & Four Ventilation Exhaust Duct Radiation Monitors Not Performed.Caused by Procedural Deficiency.Procedures Clarified + (10:59:49, 13 December 2024)
- RBG-19591, Forwards Suppl 9 to Environ Rept - OL Stage + (10:59:50, 13 December 2024)
- ML20100E272 + (10:59:51, 13 December 2024)
- ML20100E262 + (10:59:52, 13 December 2024)
- ML20100E263 + (10:59:52, 13 December 2024)
- 05000366/LER-1984-031, :on 841031,reactor Water Cleanup Inboard Isolation Valve 2G31-F002 Isolated Due to High Equipment Room Temp.Caused by Pump Shaft Seal & Two Pump Vent Valves Leaking.Seal Replaced & Valves Repaired + (10:59:54, 13 December 2024)
- ML20100E258 + (10:59:55, 13 December 2024)
- ST-HL-AE-1213, Forwards Revs to Security,Safeguards Contingency & Security Personnel Training & Qualification Plans & Responses to NRC 850205 Comments on Security Plan.Revs & Comments Withheld (Ref 10CFR73.21) + (10:59:56, 13 December 2024)
- 05000374/LER-1984-072-01, :on 841029,reactor Bldg Ventilation Sys Tripped Due to Closing of Isolation Dampers.Caused by Personnel Error.Isolation Dampers Reopened & Reactor Bldg Ventilation Sys Restarted + (10:59:58, 13 December 2024)
- ML20100E237 + (10:59:59, 13 December 2024)
- ML20100E236 + (11:00:00, 13 December 2024)
- 05000368/LER-1984-026, :on 841026,automatic Reactor Trip Occurred as Result of Dropped Control Element Assembly.Caused by Shorted Upper Gripper Coil for Control Element Assembly 7. Coil Replaced + (11:00:02, 13 December 2024)
- TAC:54704 + (11:00:03, 13 December 2024)
- ML20100E227 + (11:00:12, 13 December 2024)
- B11372, Informs of Plans to Perform Fuel Surveillance Insps During Cycle 7 Refueling Outage,Per 831104 Commitment.Insps Will Include Irradiated Fuel Assemblies to Be Reinserted in Cycle 7 & Control Element Assemblies + (11:00:13, 13 December 2024)
- ML20100E207 + (11:00:16, 13 December 2024)
- ML20100E201 + (11:00:18, 13 December 2024)
- ML20100E191 + (11:00:20, 13 December 2024)
- 05000373/LER-1984-072, :on 841030,air Found Leaking Out of Doors on Standby Gas Treatment Train.Caused by Malfunctioning Flow Controller & Improperly Closed Doors.Doors Properly Closed & Flow Controller Repaired + (11:00:21, 13 December 2024)
- ML20100E156 + (11:00:23, 13 December 2024)
- 05000482/LER-1995-003, :on 950719,failed to Implement Proper Isolation & Separation of Temporary Cables.Caused by Insufficient Personnel Awareness of Isolation & Seperation Requirements. Qualified Reviewer Procedure Program Developed + (11:00:25, 13 December 2024)
- ML20100E147 + (11:00:28, 13 December 2024)
- ML20100E131 + (11:00:29, 13 December 2024)
- ML20100E135 + (11:00:29, 13 December 2024)
- ML20100E125 + (11:00:30, 13 December 2024)
- ML20100E105 + (11:00:31, 13 December 2024)
- ML20100E100 + (11:00:31, 13 December 2024)
- ML20100E095 + (11:00:32, 13 December 2024)
- ML20100E092 + (11:00:33, 13 December 2024)
- ML20100E083 + (11:00:33, 13 December 2024)
- ML20100E065 + (11:00:34, 13 December 2024)
- NG-96-0120, Informs NRC That No Safety Valve/Safety Relief Valve Failures/Challenges Occurred During CY95 + (11:00:35, 13 December 2024)
- ML20100E040 + (11:00:35, 13 December 2024)