Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000263/LER-1992-013-02, :on 920930,identified That Fire Barrier Damper Had Not Been Inspected as Required by Ts.Caused by Failure to Include Damper in Surveillance Program.Fire Watch Established & Damper Inspected + (03:39:36, 13 December 2024)
- ML20116D967 + (03:39:38, 13 December 2024)
- ML20116D961 + (03:39:39, 13 December 2024)
- ML20116D956 + (03:39:40, 13 December 2024)
- ML20116D955 + (03:39:42, 13 December 2024)
- 05000366/LER-1985-009-01, :on 850319,RCIC Steam Supply Primary Containment Inboard Isolation Valve 2E51-F007 Inadvertently Closed.Caused by Personnel Error.Isolation Logic Reset & Valve Returned to Open Position + (03:39:45, 13 December 2024)
- ML20116D944 + (03:39:46, 13 December 2024)
- ML20116D938 + (03:39:51, 13 December 2024)
- ML20116D930 + (03:39:52, 13 December 2024)
- 05000259/LER-1985-008-02, :on 850315,discovered Listed Valves Not Local Leak Tested.Caused by Failure to Identify Valves Per 10CFR50.Two Valves Failed Subsequent Test & Unit Manually Scrammed.Two Other Valves to Be Modified + (03:39:58, 13 December 2024)
- 05000366/LER-1992-018-01, :on 920928,PCIS Valve Automatically Isolated & Tripped Operating RWCU Sys Pump.Cause Unknown.Fuse Replaced & Sys Returned to Service + (03:40:01, 13 December 2024)
- 05000482/LER-1992-015, :on 921007,discovered That ESW & EDG Declared Inoperable During Testing.Caused by Cognitive Personnel Error.Individuals Involved Will Prepare Presentation Stressing Compliance W/Ts + (03:40:04, 13 December 2024)
- 05000362/LER-1985-008-01, :on 850319,reactor Tripped Due to High Steam Generator Level When Main Feed Regulating Valve FV-1111 Failed 80% Open.Caused by Corrosive Capscrew Which Allowed Detachment of Feedback Mechanism from Valve + (03:40:07, 13 December 2024)
- ML20116D909 + (03:40:09, 13 December 2024)
- ML20116D902 + (03:40:10, 13 December 2024)
- ML20116D901 + (03:40:11, 13 December 2024)
- ML20116D898 + (03:40:12, 13 December 2024)
- ML20116D892 + (03:40:16, 13 December 2024)
- ML20116D889 + (03:40:17, 13 December 2024)
- JAFP-96-0291, Informs of Util Intent to Install Alternate Dhrs at Plant in Advance of Refueling Outage 12,scheduled to Commence in Oct 1996.Info Encl Provides Details of Sys Design & Safety Considerations Pertinent to Sys Installation & Testing + (03:40:18, 13 December 2024)
- ML20116D879 + (03:40:20, 13 December 2024)
- ML20116D878 + (03:40:21, 13 December 2024)
- 05000321/LER-1992-025, :on 920930,setpoint Drift in Protective Relay Results in Multiple Actuations of Esf.Caused by One RPS Bus Power Supply Overvoltage Relay.Overvoltage Relay Recalibrated & Sys Return to Normal + (03:40:23, 13 December 2024)
- NSD-NRC-96-4782, Forwards Proprietary Presentation Matl Used by Westinghouse at 960606 Meeting on Wgothic Computer Code.Proprietary Encl Withheld,Per 10CFR2.790 + (03:40:24, 13 December 2024)
- ML20116D865 + (03:40:25, 13 December 2024)
- LD-85-021, Withdraws Encl Info Re Proposed CESSAR Changes to Reduce Min Required LPSI & HPSI Flows.Reanalysis of CESSAR Events Provided on plant-specific Basis.Evaluation of Events for HPSI & LPSI Changes Impractical + (03:40:27, 13 December 2024)
- GO2-92-249, Forwards Licensee Event Rept 92-037-01 & Provides Update Info Re Manual Reactor Scram Due to Core Instability & Associated Reportable Events + (03:40:28, 13 December 2024)
- ML20116D836 + (03:40:29, 13 December 2024)
- 05000366/LER-1992-019-01, :on 920928,personnel Notified That Test Results for SRV Exhibited Drift in Mechanical Setpoint Due to corrosion-induced Bonding.C/A Includes Installing Sys That Will Provide Electrical Signals to SRV + (03:40:31, 13 December 2024)
- ML20116D831 + (03:40:33, 13 December 2024)
- ML20116D828 + (03:40:34, 13 December 2024)
- ML20116D824 + (03:40:35, 13 December 2024)
- ML20116D816 + (03:40:36, 13 December 2024)
- ML20116D813 + (03:40:37, 13 December 2024)
- ML20116D812 + (03:40:38, 13 December 2024)
- 05000395/LER-1985-006, :on 850320,discovered Senior Reactor Operator License Number SOP-20001 Expired 850203 W/O Submitting Renewal Application.Caused by Personnel Oversight.Licensee Will Provide Better Administrative Control + (03:40:41, 13 December 2024)
- ML20116D802 + (03:40:42, 13 December 2024)
- 05000278/LER-1985-008-01, :on 850313,suppression Pool Water Level Rose to 15.3 ft,0.4 Ft Above Tech Spec Limit.Caused by Operator Mistakenly Opening Torus Test Bypass Valve.Torus Pump Used to Lower Water Level & Operator Disciplined + (03:40:44, 13 December 2024)
- ML20116D792 + (03:40:45, 13 December 2024)
- 05000286/LER-1985-003-01, :on 850319,reactor Trip Breaker Opened, Initiating Unit Trip.Possibly Caused by Inadvertent Actuation of Manual Trip Lever.Testing & Preventive Maint Found No Irregularities + (03:40:48, 13 December 2024)
- ML20116D781 + (03:40:52, 13 December 2024)
- HL-5207, Forwards Non-proprietary SNCH-9501 & Proprietary SNCH-9501-P, BWR Steady State & Transient Analysis Methods Benchmarking Licensing Topical Rept, Per GL 83-11. Proprietary Encl Withheld (Ref 10CFR2.790) + (03:40:53, 13 December 2024)
- 05000423/LER-1992-123, :on 921003,determined That Surveillance Testing for Emergency 4,160 Volt Undervoltage Relays Did Not Satisfy Requirements of Ts,Due to Incorrect Survillance Procedure. Procedures Will Be Revised Per TS Requirements + (03:40:55, 13 December 2024)
- LD-92-106, Forwards Level 1 PRA Rev of Sys 80+ Std Design PRA, Including Chapters 1-6,9 & 10.Rev Closes 16 Open & Confirmatory Issues in Sys 80+ Dser & Specific Sections of Encl Rept Will Be Provided by 921115 + (03:40:56, 13 December 2024)
- ML20116D772 + (03:40:58, 13 December 2024)
- ML20116D768 + (03:40:59, 13 December 2024)
- 05000275/LER-1985-012, :on 850321,automatic Reactor & Turbine Trips Occurred.Caused by Technicians Inadvertently Shorting 115-volt Vital Power Supply While Testing Level Channels. Personnel Reinstructed + (03:41:03, 13 December 2024)
- ML20116D747 + (03:41:05, 13 December 2024)
- 05000286/LER-1985-004-01, :on 850320,control Power Fuses for Nuclear Instrumentation Range Channel 36 Failed,Resulting in Three Reactor Trips.Caused by Current Leakage Across Test Switch. Testing Performed.Investigation Continuing + (03:41:09, 13 December 2024)
- ML20116D730 + (03:41:15, 13 December 2024)
- ML20116D734 + (03:41:15, 13 December 2024)