- 05000272/LER-1991-021, :on 910522 & 0603,Tech Spec 3/4.8.3.1 Noncompliance Discovered.Caused by Personnel Error.Amend Implementation Event Reviewed W/Prior Tech Spec Administrator +
- 05000311/LER-1990-031, :on 900802,valve 21MS18 Main Steam Line Isolation Control Circuit Failed to Close.Caused by Failure to Wire Control Circuitry Per design.Seal-in Contacts Removed from Circuit & Circuit Adjusted +
- ML20050B362 +
- ML20063A397 +
- ML20084F634 +
- ML20084F602 +
- ML20076L201 +
- ML20095D739 +
- ML20090D400 +
- ML20117K960 +
- ML20117D534 +
- ML20084B013 +
- ML20148F097 +
- ML20153F383 +
- ML20206M358 +
- ML20214K399 +
- IR 05000423/1985098 +
- ML20217R341 +
- ST-HL-AE-4815, Forwards Description of Util Review of NRC Accident Sequence Precursor Analysis W/Results of Util IPE Analysis +
- 05000254/LER-1989-007-05, :on 890609,refuel Floor 1A Radiation Monitor Spiked High Causing Reactor Bldg Vents & Control Room HVAC to Isolate & auto-start.Caused by Faulty Geiger Mueller Tube in Monitor.Monitor Repaired & Tested +
- 05000413/LER-1986-035, :on 860705,main Feedwater Isolation Occurred Due to Steam Generator D hi-hi Level.Caused by Defective Procedure.Isolation Signal Reset & Feedwater Flow Restored. Sufficient Guidance Restored to Procedure +
- 05000499/LER-1998-004-01, :on 981228,plant Was Shutdown Required by TS 3.3.2.Caused by Failure in Ssps Test Circuitry.Testing Circuit Card Was Replaced +
- 05000295/LER-1997-010-01, :on 970404,radiation Area Surveys Were Missed. Caused by Inadequate TS Review.Nso,Unit Supervisor & Shift Engineer,Counseled +
- 05000272/LER-1985-008-01, :on 850729,containment Sump in-leakage Rate Reached 1.3 Gpm.Caused by Leaking Svc Water from Pipe Plug Located on Containment Fan Coil Unit 11 Motor Cooler.Leaking Pipe Plug Tightened +
- 05000461/LER-1996-005, :on 960411,failure to Follow Procedures During Completion of one-rod-out Interlock Test Results in Reactor Mode Switch Not Locked in Refuel During Control Rod Exercising as Required by TS +
- 05000416/LER-1992-018, :on 921013,EDGs 11 & 12,mfg by Transamerica Delavel,Inc Rolled Via Air Start Sys More than 8 H Following Shutdown.Caused by Lack of Effective Method for Triggering Air Rolls.Requirements Amended +
- IR 05000324/1982005 +
- ML20033F368 +
- ML20092B065 +
- 05000281/LER-1991-008-02, :on 910814,charging Pump Component Cooling Pump a Tagged Out to Replace Pump Discharge Check Valve & Exceeded 24 H Lco.Caused by Unanticipated Delays During Maint.Engineering Evaluation Performed +
- 05000280/LER-1988-032, :on 880913,three Emergency Diesel Generators Declared Inoperable Due to Design Deficiency.Caused by Incorrect Design Assumption That Worst Case Scenario Was hi-hi Actuation.Design Change Generated +
- 05000272/LER-1990-006-01, :on 900302,ESF Actuation & Containment Ventilation Isolation Occurred.Caused by Design/Equipment Problem.Channel Backplane Replaced & Functional Test Completed +
- ML18152A408 +
- ML18337A005 +
- ML17244A598 +
- B18782, September 2002 Monthly Operating Report for Millstone Units 2 and 3 +
- IR 05000295/1997020 +
- ML20214G986 +
- 05000341/LER-1989-038, :on 891223,smoke Discovered in Vicinity of High Pressure Turbine & Reactor Manually Scrammed.Caused by Oil Soaked Lagging Pads Which Ignited When Oil Flash Point Reached.Damaged Insulation Pads Replaced +