- ENS 43273 +
- 05000440/LER-2001-001 +
- IR 05000315/2009003 +
- ML20052G120 +
- ML20045B448 +
- ML042670254 +
- ML042600282 +
- ML022000056 +
- ML20086G656 +
- ML20086F698 +
- ML20115C743 +
- ML20113E661 +
- ML20134E908 +
- ML20133B790 +
- 05000311/LER-1982-121, Forwards LER 82-121/03L-0.Detailed Event Analysis Encl +
- ML20245B737 +
- ML20248F108 +
- IR 05000254/1987019 +
- ML22014A020 +
- 05000341/LER-1987-017, :on 870513,south Reactor Feed Pump Turbine (Srfpt) Tripped Due to Apparent Srfpt High Pressure Casing Drain Valve Being Closed During Startup.Caused by Inadequate Procedure.Procedure Revised +
- 05000387/LER-1987-001-01, :on 870109,two RWCU Sys Automatic Isolations Occurred Due to High Flow.Caused by Operations Personnel Failing to Verify Sys Filled & Vented Prior to Placing Sys in Svc After Maint.Sys Refilled & Vented +
- 05000265/LER-1987-012-09, :on 870918,suppression Chamber to Drywell Vacuum Breaker Failed to Close After Testing.Caused by Problem W/Air Operator Portion of Vacuum Breaker.Vacuum Breakers Will Be Inspected & Repaired +
- 05000498/LER-1988-018, :on 880212,safety Injection Actuation Initiated by Excessive Cooldown Protection Logic Following RCS Flow Coastdown Measurement Test.Caused by Formation of Slug of Cool Water in Coolant Loop.Test to Be Revised +
- 05000413/LER-1985-044, :on 850622,steam Generator lo-lo Level Reactor Trip Occurred.Caused by Main Feedwater Pump Turbine Speed Increasing W/O Proper Mode Due to Miscommunication.Sys Affected Returned to Normal Alignment +
- 05000244/LER-1985-001, :on 850116,series of Blown Fuses in Computer Resulted in Actuation of 90 Alarms on Computer Alarm Typewriter at Time I&C Technicians Removing & Restoring Foxboro Channels.Caused by Personnel Error +
- 05000254/LER-1985-001-08, :on 850205,during HPCI Pump Operability Test,Hpci Turbine Could Not Be Reset from Control Room. Caused by Failure of HPCI Turbine Trip & Reset Solenoid Valves of HPCI Stop Valve.Valves Repaired +
- 05000269/LER-1995-007, :on 951106,LPIS Was Technically Inoperable Due to Deficient Design Change.Valves Modified to Prevent Key from Vibrating Out of Keyway +
- 05000499/LER-1992-003, :on 920224,feedwater Flow Oscillations Observed on turbine-driven SG Feedwater Pump 23,resulting in Reactor Trip.Caused by Rain Water Leaking Through Expansion Joints.Control Sys Dried Out +
- 05000353/LER-1994-008-01, :on 940813,Unit 2 Max Power Level of 100% Exceeded by Approx 2% Due to Malfunction of Recirculation Pump a M/G Set Scoop Tube Positioner Servo Amplifier.Servo Amplifier Will Be Adjusted +
- 05000338/LER-1993-013, :on 930414,identified Addl Missed Surveillance to Functionally Test Entire Circuitry for Manual Phase a Isolation Switches.Caused by Personnel Error.Periodic Test Procedures Will Preclude Recurrence +
- ML20039D329 +
- 05000293/LER-1981-012-03, /03L-0:on 810403,4 Kv Breaker A507,feeding Core Spray Pump P215A,inadvertently Closed During Routine Keep Fill Checks on Low Pressure ECCS Sys.Caused by Inconsistency in Automatic & Close/Trip Sequence Timings +
- 05000320/LER-1981-002-01, /01L-0:on 810126,emergency Diesel Generator B Determined Inoperable on 810119.Caused by Auxiliary Operator Not Completing Switching Order.No Corrective Action.Operator Counseled +
- 05000265/LER-1987-012-01, :on 870918,while Performing Qos 1600-1, Vacuum Breaker 2-1601-33E Remained Open After Testing.Caused by Binding in Test Cylinder Portion of Vacuum Breaker. Nuclear Work Requests Completed +
- 05000316/LER-1994-008-01, :on 941211,4B Feedwater Heater Extreme High Level Alarm Received & Turbine Trip Resulted.Cause Related to Configuration of Alternate Drain line.High-high Level Alarm Switches Repaired & Tested +
- ML17199F997 +
- 05000338/LER-2016-001, Regarding Emergency Diesel Generators Automatic Start Due to Loss of Power to C Reserve Station Service Transformer +
- 05000311/LER-2009-002, Regarding 22 Component Cooling Heat Exchanger Inoperable for Greater than Allowed Outage Time +
- ML17199U464 +
- 05000289/LER-1999-006, :on 990525,inability of Pressurizer Support Bolts to Meet FSAR Requirements,Was Determined.Cause Not Identified.Performed Operability Review & Determined That Pressurizer Would Remain Operable Under Design Conditions +