- ENS 40592 +
- 05000346/LER-1917-002, For Davis-Besse Nuclear Power Station, Unit 1, Regarding Auxiliary Feed Water Pump Turbine Bearing Damaged Due to Improperly Marked Lubricating Oil Sight Glass +
- ML112101662 +
- ML111940492 +
- ML100850453 +
- ML100610448 +
- ML080230511 +
- ML16281A591 +
- ML18037A772 +
- ML18141A274 +
- PLA-7699, Annual Radiological Environmental Operating Report for 2017 +
- ML19261B307 +
- ML19323F154 +
- ML040980593 +
- ML20064G435 +
- ML050190165 +
- ML043370046 +
- ML031950451 +
- ML20071B102 +
- ML20087Q110 +
- ML20097F480 +
- RBG-22911, Summary Rept of Notification of Unusual Event:On 860101,trip of Preferred Station Transformers 1RTX-XSR1A & 1RTX-XSR1C Occurred.Caused by Fancy Point Breakers Receiving Spurious Trip Signal from Fiber Optic Cable Sys.Sys Isolated +
- 05000374/LER-1987-006-05, :on 870402,during Functional/Logic Testing in Modified Primary Containment Isolation Circuitry,Unexpected Group II Isolation (ESF) Occurred.Caused by Inattentive Test Engineers.Personnel Trained on Relay Testing +
- 05000341/LER-1985-066, :on 850927,reactor Protection Sys Tripped on High Pressure Due to West Turbine Bypass Valve Closing. Caused by Noise Picked Up by Turbine Speed Pickup & Seen as Speed Signal.Gain Level Adjusted +
- 05000270/LER-1985-004-04, :on 850422,reactor Trip Occurred on Loss of Main Feedwater.Caused by Short Circuit in Terminal Block on Transformer 2T,resulting in Loss of Motor Control Ctr.Block Repaired +
- 05000382/LER-1985-003, :on 850117,while Maint Personnel Troubleshooting Ground in ESF Actuation Signal Relay Cabinet B,Two Leads Shorted,Causing Momentary Loss of Relay Control Power.Pump & Bus Restored to Svc +
- 05000267/LER-1984-013, :on 841112 & 13,both Hot Svc Facility Area Radiation Monitors Inoperable for Period Longer than Allowed by Tech Spec 4.4.3.Caused by High Voltage Power Supply Inadvertently Shorted to Ground +
- 05000265/LER-1984-009-06, :on 840805,reactor Protection Sys Motor Generator Set 2B Tripped,Resulting in Loss of Reactor Protection Sys Bus 2B.Caused by Failure of Reactor Protection Sys Motor Generator Set Motor +
- 05000244/LER-1982-004-01, /01T-0:on 820125,fire Watches Posed as Result of Eight Inoperable Fire Detection Zones +
- 05000334/LER-1989-010-01, :on 890907,UL Test Results Indicated That Horizontally Mounted Prototype Fire Dampers Failed to Comply W/Requirements of Ul Std 555-1968.Caused by Discrepancies Between as-fabricated & Required Specs +
- 05000250/LER-1997-009, :on 971114,discovered That CR Console Switch for 3B SGFP Was Not in Start Position.Caused by Inadequate Procedural Guidance.Revised Procedures 3/4-OP-074,informed Personnel of Event & Performed Walkdown of CR +
- IR 05000269/1997017 +
- IR 05000261/1992017 +
- 05000263/LER-2012-003-01, Regarding Automatic Reactor Scram During Maintenance on 4160V 12-Bus Ammeter +
- 05000263/LER-2012-003, Regarding Automatic Reactor Scram During Maintenance on 4160V 12-Bus Ammeter +
- 05000265/LER-2002-005, Failure of Low Pressure Coolant Injection Logic Test Due to a Detached Wire +
- 05000266/LER-1998-013, :on 980416,discovered That Discharge Pressure Indicator Root Valves for Containment Spray Pumps Were Not Shut as Required.Caused by Failure to Maintain Adequate Configuration Control.Shut Subject Root Valves +
- 05000440/LER-1997-016, :on 971219,vibration-induced Turbine electro- Hydraulic Control Sys Fluid Leak Resulted in Reactor Protection Sys & Esf.Caused by vibration-induced Fatigue Failure.Ehc Tubing Compression Fittings,Replaced +
- 05000270/LER-1985-004, :on 850422,reactor Trip Occurred on Loss of Main Feedwater.Caused by Loss of Motor Control Ctrs 2XC & 2XB Due to Two Grounded Terminal Boards.Grounded Terminal Boards Replaced +
- 05000341/LER-1997-005, :on 970307,RBCCW to EECW Return & Supply Isolation Valve Interlocks,Installed in EECW Makeup Tank Isolation Valve Circuit Between Dedicated Shutdown Panel & Opening Coil.Caused by Inadequate Design.Revised Procedures +
- 05000373/LER-1984-082, :on 841124,reactor Water Cleanup Sys Isolated on High Differential Flow.Caused by Reactor Startup Due to Water Temp,Pressure & Density Differences Between Startup Operations & Instrument Calibr +
- 05000333/LER-1995-010-01, :on 950530,TS Required Plant Shutdown Due to Unidentified Leakage Into Drywell.Repacked Valve 02-RWR-52B Using Current Maint Practice of Repacking w/non-asbestos Graphite +