Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NOC-AE-0208, Requests Approval to Use ASME Section IX Code Cases 2142-1 & 2143-1 in Fabrication & Installation of Replacement SGs for Plant + (ML20236G470)
- ML20236G477 + (ML20236G477)
- 05000369/LER-1998-003-02, :on 980529,inoperability of 1CF-30 During Unit 1 Cycle 12 from 970906-1117,occurred.Caused by Improper Valve Assembly.Valve Logged Inoperable Under Requirements of TS 3/4.6.3 & Operators Entered Action Statement + (ML20236G478)
- IA-87-480, Final Response to FOIA Request for Reed Rept & CP Cohen Containment Study.Forwards Reed Rept.Cp Cohen Containment Study Unavailable.W/O Encl + (ML20236G479)
- ML20236G479 + (ML20236G479)
- ML20236G480 + (ML20236G480)
- 2CAN069804, Application for Amend to License NPF-6,increasing Allowable as-found Lift Setting Tolerances on MSSVs & Pressurizer Safety Valves + (ML20236G483)
- 05000424/LER-1987-043, :on 870628,improper Performance of Containment Pressure Surveillance Discovered.Caused by Personnel Error. Temporary Change to Procedure 1400-1 Incorporated Into Applicable Data Sheets + (ML20236G485)
- ML20236G487 + (ML20236G487)
- ML20236G490 + (ML20236G490)
- ML20236G491 + (ML20236G491)
- 05000285/LER-1998-008, :on 980528,noted That Plant Had Operated Outside of Design Basis of AFW Sys Due to Overpressurization of AFW Piping.Caused by Misadjustment of Governor.Installed Mod to Sense Overpressure Condition + (ML20236G493)
- ML20236G494 + (ML20236G494)
- ML20236G495 + (ML20236G495)
- PNO-V-87-071, on 871024,main Furnace at Precision Castparts Corp Exploded.Caused by Water Invading Evacuated Chamber of Arc Furnace.All Furnace Debris Packaged & Shipped for Burial as Low Specific Activity Waste + (ML20236G496)
- ML20236G497 + (ML20236G497)
- IR 05000301/1987016 + (ML20236G498)
- ML20236G500 + (ML20236G500)
- ML20236G504 + (ML20236G504)
- ML20236G505 + (ML20236G505)
- PY-CEI-NRR-0743, Forwards LERs 87-068-00 & 87-069-00 + (ML20236G507)
- ML20236G509 + (ML20236G509)
- ML20236G511 + (ML20236G511)
- ML20236G512 + (ML20236G512)
- 2CAN069807, Application for Amend to License NPF-6,revising Surveillance Testing Requirements for Unit 2 Direct Current Electrical Distribution Sys & to Reflect Installation of New Inverters During Next Scheduled Refueling Outage + (ML20236G513)
- ML20236G517 + (ML20236G517)
- ML20236G518 + (ML20236G518)
- PNO-I-87-069, corrects & Updates Info Contained in 870728 PNO-I-87-068 Re 870727 Apparent Contamination of Worker W/ Radium.Licensee Subsequently Determined That Worker Contaminated w/Pm-147.Clean-up Will Be Performed by Worker + (ML20236G519)
- ML20236G520 + (ML20236G520)
- ML20236G521 + (ML20236G521)
- ML20236G525 + (ML20236G525)
- ML20236G526 + (ML20236G526)
- ML20236G527 + (ML20236G527)
- ST-HL-AE-2317, Forwards Revised Description of security-related Activities Proposed After Fuel Loading & Physical Security Plan Changes.Encls Withheld (Ref 10CFR73.21) + (ML20236G529)
- ML20236G530 + (ML20236G530)
- ML20236G531 + (ML20236G531)
- 05000440/LER-1987-068, :on 870929,RHR Shutdown Cooling Inboard Isolation Occurred.Caused by Personnel Not Paying Sufficient Attention to Detail to Identify Any Drifting in Pressure Regulator During Performance of Test.Procedures Revised + (ML20236G532)
- ML20236G534 + (ML20236G534)
- ML20236G538 + (ML20236G538)
- ML20236G539 + (ML20236G539)
- ML20236G542 + (ML20236G542)
- ML20236G544 + (ML20236G544)
- ML20236G545 + (ML20236G545)
- ML20236G546 + (ML20236G546)
- ML20236G547 + (ML20236G547)
- 2CAN069805, Application for Amend to License NPF-6,providing Range of Acceptable Values for 4160 Volt Bus Loss of Voltage Values, to Be Consistent W/Requirements Set Forth in NUREG-1432,rev 1 + (ML20236G548)
- ML20236G552 + (ML20236G552)
- ST-HL-AE-2316, Requests Exemption from Final Tech Spec Surveillance Requirement 4.3.4.2.d Re Disassembly & Insp of Valves Based on Listed Reasons,Including Fact That Valves Have Not Been in Svc Conditions for Any Degradation to Occur + (ML20236G553)
- ML20236G557 + (ML20236G557)
- ML20236G559 + (ML20236G559)
- ML20236G561 + (ML20236G561)