- ML20209A922 + (ML20209A922)
- ML20209A923 + (ML20209A923)
- ML20209A924 + (ML20209A924)
- ML20209A928 + (ML20209A928)
- ML20209A931 + (ML20209A931)
- ML20209A932 + (ML20209A932)
- ML20209A933 + (ML20209A933)
- ML20209A936 + (ML20209A936)
- ML20209A940 + (ML20209A940)
- ML20209A943 + (ML20209A943)
- ML20209A944 + (ML20209A944)
- IR 05000413/1987008 + (ML20209A949)
- ML20209A951 + (ML20209A951)
- ML20209A952 + (ML20209A952)
- ML20209A955 + (ML20209A955)
- ML20209A957 + (ML20209A957)
- ML20209A958 + (ML20209A958)
- ML20209A959 + (ML20209A959)
- ML20209A962 + (ML20209A962)
- ML20209A963 + (ML20209A963)
- ML20209A966 + (ML20209A966)
- ML20209A967 + (ML20209A967)
- 05000341/LER-1987-009, :on 870325,RHR Pump C Tripped Due to Inboard Isolation Valve Closing.Caused by Intermittent Failure of Master Trip Unit.Futher Investigation of Master Trip Unit Will Be Made by Mfg.Isolation Logic Reset + (ML20209A968)
- ML20209A970 + (ML20209A970)
- ML20209A972 + (ML20209A972)
- ML20209A973 + (ML20209A973)
- ML20209A978 + (ML20209A978)
- ML20209A980 + (ML20209A980)
- ML20209A981 + (ML20209A981)
- ML20209A982 + (ML20209A982)
- ML20209A983 + (ML20209A983)
- ML20209A984 + (ML20209A984)
- ML20209A986 + (ML20209A986)
- ML20209A987 + (ML20209A987)
- ML20209A989 + (ML20209A989)
- ML20209A992 + (ML20209A992)
- IR 05000424/1987006 + (ML20209A995)
- ML20209A998 + (ML20209A998)
- ML20209A999 + (ML20209A999)
- ML20209B000 + (ML20209B000)
- ML20209B004 + (ML20209B004)
- ML20209B005 + (ML20209B005)
- ML20209B007 + (ML20209B007)
- 05000325/LER-1987-011-01, :on 870323,safety Relief Valve SRV F013H Would Not Lift at Test Pressure & SRV F013C,E,F,G,J,K & L Lifted at Pressure Above Plus/Minus 1% Tolerance Allowed by Tech Specs.Caused by Corrosion Bonding + (ML20209B008)
- ML20209B009 + (ML20209B009)
- PNO-IV-86-028A, on 860829,beam Lowered Through Equipment Hatch in Containment Bldg Fell,Striking Pipefitter on Head. Cause Not Stated.Pipefitter Suffered Massive Trauma & Died After Air Evacuation to Hosp.Press Release Issued + (ML20209B011)
- ML20209B015 + (ML20209B015)
- ML20209B017 + (ML20209B017)
- ML20209B018 + (ML20209B018)
- ST-HL-AE-2081, Forwards Request for Relief from ASME Boiler & Pressure Vessel Code Section XI Requirements for Testing of Snubbers at Facility.Relief Eliminates Duplication of Requirements Already in Tech Specs + (ML20209B021)