- ML20155K403 + (ML20155K403)
- ML20155K404 + (ML20155K404)
- ML20155K406 + (ML20155K406)
- ML20155K408 + (ML20155K408)
- ML20155K411 + (ML20155K411)
- ML20155K412 + (ML20155K412)
- 05000498/LER-1988-029, :on 880424,Tech Spec 3.0.3 Entered on Two Occasions for Total of 17 Minutes During Testing of Steam Generator Porvs.Caused by Shift Supervisor Determination Action Constituted Acceptable Entry + (ML20155K413)
- ML20155K416 + (ML20155K416)
- ML20155K417 + (ML20155K417)
- TXX-4827, Forwards Responses to NRC 860515 Questions Re Results Rept for Isap VII.b.2 on Valve Disassembly.No Cases of Using non-ASME Bonnet on ASME Valve Found.Valve Disassembly Accomplished Under Procedure CP-CPM-6.9 Prior to 830128 + (ML20155K418)
- ML20155K419 + (ML20155K419)
- ML20155K420 + (ML20155K420)
- ML20155K421 + (ML20155K421)
- ML20155K422 + (ML20155K422)
- ML20155K425 + (ML20155K425)
- ML20155K429 + (ML20155K429)
- ML20155K431 + (ML20155K431)
- ML20155K432 + (ML20155K432)
- ML20155K435 + (ML20155K435)
- IR 05000334/1998007 + (ML20155K436)
- ML20155K437 + (ML20155K437)
- ML20155K439 + (ML20155K439)
- 05000482/LER-1986-025, :on 860422,both Trains of Safety Injection Flow to RCS Cold Legs Disabled by Closure of Valve EM HV-8835. Caused by Personnel Failing to Recognize Plant Condition. Retraining on ECCS Manipulations Planned + (ML20155K440)
- ML20155K442 + (ML20155K442)
- ML20155K443 + (ML20155K443)
- ML20155K444 + (ML20155K444)
- ML20155K447 + (ML20155K447)
- ML20155K448 + (ML20155K448)
- ML20155K450 + (ML20155K450)
- ML20155K451 + (ML20155K451)
- ML20155K453 + (ML20155K453)
- ML20155K454 + (ML20155K454)
- ML20155K455 + (ML20155K455)
- 05000498/LER-1988-021, :on 880224,ESF Actuation Due to Inverter Failure.Caused by Dc to Dc Converter Assembly Failure.Plant Engineering Dept Reviewed Results of Vendor Failure Analysis.Failures Identified as Random + (ML20155K456)
- ML20155K458 + (ML20155K458)
- ML20155K460 + (ML20155K460)
- ML20155K461 + (ML20155K461)
- ML20155K462 + (ML20155K462)
- ML20155K463 + (ML20155K463)
- ML20155K464 + (ML20155K464)
- ML20155K466 + (ML20155K466)
- ML20155K467 + (ML20155K467)
- ML20155K468 + (ML20155K468)
- ML20155K469 + (ML20155K469)
- ML20155K470 + (ML20155K470)
- ML20155K474 + (ML20155K474)
- ML20155K475 + (ML20155K475)
- ML20155K477 + (ML20155K477)
- ML20155K478 + (ML20155K478)
- ML20155K480 + (ML20155K480)
- ML20155K481 + (ML20155K481)