- IR 05000267/1988014 + (ML20154C336)
- ML20154C337 + (ML20154C337)
- ML20154C338 + (ML20154C338)
- ML20154C339 + (ML20154C339)
- ML20154C340 + (ML20154C340)
- ML20154C342 + (ML20154C342)
- ML20154C344 + (ML20154C344)
- ML20154C345 + (ML20154C345)
- ML20154C346 + (ML20154C346)
- ML20154C347 + (ML20154C347)
- ML20154C350 + (ML20154C350)
- ML20154C351 + (ML20154C351)
- ML20154C353 + (ML20154C353)
- 05000424/LER-1988-011, :on 880411,alert Alarm & Alarm Setpoints for Turbine Bldg Drain Effluent Monitor Set Too High Violating Tech Specs.Caused by Inadequate Administrative Controls of Alarm Setpoints.Controlling Procedure Revised + (ML20154C355)
- ML20154C357 + (ML20154C357)
- ML20154C359 + (ML20154C359)
- ML20154C360 + (ML20154C360)
- ML20154C362 + (ML20154C362)
- ML20154C364 + (ML20154C364)
- ML20154C366 + (ML20154C366)
- ML20154C367 + (ML20154C367)
- IR 05000498/1998013 + (ML20154C368)
- ML20154C369 + (ML20154C369)
- ML20154C372 + (ML20154C372)
- ML20154C379 + (ML20154C379)
- ML20154C383 + (ML20154C383)
- NG-98-1674, Requests Authorization to Utilize Alternative Requirements Described in Code Case N-508-1, Rotation of Serviced Snubbers & Pressure Relief Valves for Purpose of Testing + (ML20154C384)
- 05000445/LER-1998-006, :on 980831,discovered That TS Surveillance for HR Sys May Not Have Been Adequate.Caused by Improper Surveillance Methodology.Conducted Surveillance Testing of HRs & Revised Applicable Procedures.With + (ML20154C386)
- ML20154C387 + (ML20154C387)
- ML20154C389 + (ML20154C389)
- ML20154C394 + (ML20154C394)
- ML20154C398 + (ML20154C398)
- ML20154C399 + (ML20154C399)
- ML20154C400 + (ML20154C400)
- ML20154C402 + (ML20154C402)
- ML20154C403 + (ML20154C403)
- ML20154C409 + (ML20154C409)
- ML20154C410 + (ML20154C410)
- ML20154C411 + (ML20154C411)
- ML20154C413 + (ML20154C413)
- 05000374/LER-1988-005-05, :on 880412,flow Switch FS-2E22-N006 Found W/ Setpoint out-of-tolerance Below Reject Limit.Caused by Setpoint Drift.Switch Sent to Mfg for Disassembly & Insp & Replacement Switch Installed + (ML20154C415)
- ML20154C416 + (ML20154C416)
- IR 05000369/1998008 + (ML20154C418)
- ML20154C421 + (ML20154C421)
- ML20154C422 + (ML20154C422)
- ML20154C426 + (ML20154C426)
- ML20154C427 + (ML20154C427)
- ML20154C429 + (ML20154C429)
- ML20154C430 + (ML20154C430)
- ML20154C431 + (ML20154C431)
- AECM-86-0054, Forwards Proprietary NEDC-31148P, Grand Gulf Unit 1,Reactor Internals Vibration Measurements... & EqDE-06-0286, Grand Gulf Unit 1 Reactor Internals..., Per Reg Guide 1.20 Requirements.Affidavit Encl.Repts Withheld (Ref 10CFR2.790) + (ML20154C432)