- 05000312/LER-1978-006-03, /03L-0:on 780611,during Normal Operation,Increased Leakage Noticed,Between 1.1-1.7 Gallons/Min.Caused by Leaking Pressure Safety Valves & Block Valve on Electromatic Relief Valve.Valves Replaced or Reworked + (ML20147B254)
- ML20147B256 + (ML20147B256)
- ML20147B257 + (ML20147B257)
- ML20147B258 + (ML20147B258)
- ML20147B261 + (ML20147B261)
- ML20147B262 + (ML20147B262)
- ML20147B263 + (ML20147B263)
- 05000346/LER-1978-095, Forwards LER 78-095/03L-0 + (ML20147B265)
- 05000498/LER-1988-010, :on 870923,maint Work Request Prepared Stating That Charging Header Pressure Indicator Reading 1,000 Psi More than Local Process Pressure Gauge.Caused by Lack of Identification in Tech Spec Re Subj Loop + (ML20147B266)
- ML20147B267 + (ML20147B267)
- ML20147B268 + (ML20147B268)
- 05000312/LER-1978-008, Forwards LER 78-008/02T-0 + (ML20147B271)
- ML20147B272 + (ML20147B272)
- ML20147B273 + (ML20147B273)
- ML20147B274 + (ML20147B274)
- ML20147B275 + (ML20147B275)
- ML20147B276 + (ML20147B276)
- 05000346/LER-1978-095-03, /03L-0:on 780905,station Batteries Weekly Surveillance Test Not Performed Until 780906.Caused by Personnel Error + (ML20147B278)
- ST-HL-AE-2460, Forwards Proprietary WCAP-11701 & Nonproprietary WCAP-11702, Response to NRC Questions Re Fast Response,Narrow Range, Thermowell Mounted Resistance Temp Detector, Per NRC 871218 Request for Addl Info + (ML20147B279)
- ML20147B280 + (ML20147B280)
- ML20147B281 + (ML20147B281)
- ML20147B282 + (ML20147B282)
- ML20147B285 + (ML20147B285)
- 05000316/LER-1978-066-03, /03L-0 on 780905:interlock on 650 Ft Level Containment Air Lock Failed to Function During Test, as Interlock Cable Was Too Loose to Operate Locking Mechanism. Tension Adjustment Was Added to Maintenance Prog + (ML20147B286)
- ML20147B287 + (ML20147B287)
- ML20147B289 + (ML20147B289)
- ML20147B291 + (ML20147B291)
- ML20147B292 + (ML20147B292)
- 05000348/LER-1978-061, Forwards LER 78-061/03L-0 + (ML20147B293)
- ML20147B294 + (ML20147B294)
- ML20147B295 + (ML20147B295)
- ML20147B297 + (ML20147B297)
- ML20147B298 + (ML20147B298)
- ML20147B299 + (ML20147B299)
- ML20147B300 + (ML20147B300)
- 05000316/LER-1978-065-03, /03L-0 on 780901:viscosity of Diesel Lube Oil Was Low During Routine Check Due to Fuel Oil Contamination; for Fuel Oil Injection Pumps & 1 Fuel Injectors Were Replaced + (ML20147B301)
- ML20147B303 + (ML20147B303)
- ML20147B304 + (ML20147B304)
- ML20147B305 + (ML20147B305)
- 05000312/LER-1978-008-02, /02T-0:on 780804,analysis Showed Atypical Weld Filler Wire W/High Silicon & Low Nickel Contents in Archive Weldments.Wire Mixed by Supplier W/Shipment of Mn-Mo-Ni Filler Wire.Caused by Inadequate QA + (ML20147B306)
- ML20147B307 + (ML20147B307)
- ML20147B309 + (ML20147B309)
- ML20147B310 + (ML20147B310)
- ML20147B311 + (ML20147B311)
- ML20147B314 + (ML20147B314)
- ML20147B315 + (ML20147B315)
- 05000348/LER-1978-061-03, /03L-0 on 780905:failure of 1-2A Diesel Generator to Respond to Voltage/Speed Control in Auto Due to Failure of Motorized Potentiometer(Failed Diodes)Causing the 125V DC Supply Fuses to Blow + (ML20147B318)