- ML20137X970 + (ML20137X970)
- ML20137X971 + (ML20137X971)
- ML20137X973 + (ML20137X973)
- ML20137X976 + (ML20137X976)
- 05000275/LER-1985-033, :on 851025,automatic Reactor & Turbine Trips Occurred Due to Reactor Coolant Pump Breaker Position Relay Opening Momentarily.Caused by Shorted Capacitator in Comparator Module + (ML20137X977)
- IR 05000317/1986002 + (ML20137X979)
- ML20137X980 + (ML20137X980)
- ML20137X981 + (ML20137X981)
- ML20137X984 + (ML20137X984)
- ML20137X992 + (ML20137X992)
- ML20137X994 + (ML20137X994)
- ML20137X995 + (ML20137X995)
- 05000341/LER-1996-020, :on 961203,loss of Shutdown Cooling Was Noted Due to ESF Actuation.Control Circuitry for Closure of Valve Investigated & All Connections Having Potential to de-energize Relay Checked + (ML20137X996)
- ML20137Y000 + (ML20137Y000)
- ML20137Y001 + (ML20137Y001)
- 05000416/LER-1985-010, :on 850223,ESF Actuation Occurred Due to Div 2 Inverter Trip on High Voltage.Caused by Relay Reenergizing Before Level Instruments Could Recover + (ML20137Y002)
- ML20137Y003 + (ML20137Y003)
- ML20137Y004 + (ML20137Y004)
- 05000287/LER-1985-005-05, :on 851024,anticipatory Reactor Trip Occurred on Loss of Main Feedwater Pump.Caused by Failure of Regulator Valve to Function Properly.Unit Stabilized at Hot Shutdown.Valve Positioner Will Be Installed + (ML20137Y005)
- ML20137Y006 + (ML20137Y006)
- ML20137Y007 + (ML20137Y007)
- ML20137Y009 + (ML20137Y009)
- ML20137Y013 + (ML20137Y013)
- IR 05000254/1985029 + (ML20137Y017)
- ML20137Y018 + (ML20137Y018)
- ML20137Y020 + (ML20137Y020)
- ML20137Y022 + (ML20137Y022)
- ML20137Y024 + (ML20137Y024)
- PNO-IV-97-021, on 970421,extraction Steam Line to Feedwater Heater Ruptured in Fort Calhoun Station Turbine Bldg. Licensee Restricted Access to Turbine Bldg & Implemented Respiratory Protection Requirements for Access + (ML20137Y027)
- ML20137Y030 + (ML20137Y030)
- ML20137Y033 + (ML20137Y033)
- ML20137Y034 + (ML20137Y034)
- ML20137Y035 + (ML20137Y035)
- 05000251/LER-1985-024-01, :on 851102,automatic Initiation of Standby Component Cooling Water Pump 4A Occurred.Caused by Maint & post-maint Testing Performed on auto-start Circuitry PC-611. Auto-start Circuitry Returned to Svc + (ML20137Y036)
- TXX-4724, Final Part 21 & Deficiency Rept CP-86-09 Re Defective Delaval Diesel Generator Inlet/Exhaust Valve Springs.Issue Not Reportable Under 10CFR50.55(e) + (ML20137Y037)
- 05000155/LER-1986-001, :on 860117,during Review of Fire Detection Test Procedures,Failure to Test Three Recirculation Pump Fire Detectors During 1985 Refueling Outage Noted.Caused by Procedural Inadequacy.Test Performed on 860215 + (ML20137Y040)
- ML20137Y042 + (ML20137Y042)
- ML20137Y043 + (ML20137Y043)
- 05000245/LER-1996-046-04, Forwards Suppl LER 96-046-04,documenting Event Occurring at Facility on 960627.Provides Addl Reportable Condition Identified on 970318.W/util Commitments Listed + (ML20137Y047)
- ML20137Y048 + (ML20137Y048)
- 05000270/LER-1986-001-03, :on 860131,reactor Tripped from 100% Power. Caused by Procedural Deficiency Resulting in Failure to Block Breaker Failure Initiate Relay to Power Circuit Breaker During Carrier Test.Contacts Replaced + (ML20137Y049)
- ML20137Y051 + (ML20137Y051)
- ML20137Y052 + (ML20137Y052)
- ML20137Y053 + (ML20137Y053)
- ML20137Y058 + (ML20137Y058)
- ML20137Y061 + (ML20137Y061)
- ML20137Y064 + (ML20137Y064)
- ML20137Y066 + (ML20137Y066)
- ML20137Y069 + (ML20137Y069)
- ML20137Y073 + (ML20137Y073)
- ML20137Y074 + (ML20137Y074)