UNITED STATES
+
[
g NUCLEAR REGULATORY COMMISSION
~$
E-WASHINGTON, D. C. 20555
%...../
t UNIVERSITY OF FLORIDA DOCKET NO. 50-83 i
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 16 License No. R-56 f
I
[
1.
The Nuclear Regulatory Comission (the Comission) has found that:
i A.
The application for amendment to Facility (Operating License No.
R-56, filed by The University of Florida thelicensee), dated October 17, 1985, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the j
Comission's regulations as set forth in 10 CFR Chapter I:
I B.
The facility will operate in confonnity with the amended license, the provisions sf the Act, and the rules and regulations of the 3
Comission; j
C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health i
and safety of the public, and (ii) that such activities will be l
conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common l
defense and security or to the health and safety of the public; E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied; and F.
Publication of notice of this amendment is not required since it does not involve a significant hazards consideration nor amendment of a license of the type described in 10 CFR Section 2.106(a)(2).
8512100710 851125 DR ADOCK 05000083 PDR
. 2.
Accordingly, the license is amended by changes to the technical specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of License No. R-56 is hereby amended to read as follows:
Technical Specifications The technical specifications contained in Appendix A, as revised through Amendment No. 16, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the technical specifications.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION Ceae O. =%:::= =
Cecil 0. Thomas, Chief Standardization & Special Projects Branch Division of Licensing
Attachment:
Appendix A Technical Specifications Changes Date of Issuance:
November 25, 1985 1-
1 ATTACHMENT TO LICENSE AMENDMENT NO.16 FACILITY OPERATING LICENSE NO. R-56 DOCKET NO. 50-83 Revised Appendix A te:hnical specifications are as follows:
Remove Page Add Page i
IP 12
?
Change on the revised page is identified by a marginal line.
8 I.'.
W L
F"
= _ _.
3.4.3 Reactor Vent System The reactor vent system shall be operated at all times during reactor operation.
In addition, the vent system shall be operated until the stack monitor' indicates less than 10 counts per second (cps). Whenever the reactor vent system is operat-ing, air drawn through the reactor vent system shall be continuously monitored for gross concentration of radioactive gases. The output of the monitor shall be indicated and recorded in the control room. The reactor vent system shall be imediately secured upon detection of: a failure in the monitoring system, a failure of the absolute filter, or an unanticipated high stack count rate.
3.4.4 Air Particulate Monitor The reactor cell environment shall be monitored by at least one air particulate monitor, capable of audibly warning personnel of radioactive particulate airborne contamination in the cell atmosphere.
t 3.4.5 Liquid Effluents Discharge
~
(1) The IIquid waste from the radioactive liquid waste holding tanks shall be sampled and the activity measured before release to the sanitary sewage system.
(2) Releases of radioactive liquid waste from the holding tanks / campus sanitary sewage system shall be in compliance with the limits specified in 10 CFR 20, Appendix 8. Table 1. Colmn 2, as specified in 10 CFR 20.303.
3.4.6 Solid Radioactive Waste Disposal Solid radioactive waste disposal shall be accomplished in compliance with appli-4 cable regulations and under the control of the Radiation Control Office of the j :
University of Florida.
3.5 Limitations on Experiments l
f f
Applicability: These specifications apply to all experiments or experimental f
devices installed in the reactor core or its experimental facilities.
Objectives: The objectives are to maintain operational safety and prevent damage to the reactor facility, reactor fuel, reactor core, and associated equipment; to prevent exceeding the reactor safety limits; and to minimize pote.1tial hazards j
from experimental devices.
l Specifications:
l l
(1) General The reactor manager and the radiation control officer (or their duly appointed representative) shall review and approve in writing all proposed experiments prior to their performance. The reactor manager shall refer l
to the Reactor Safety Review Subcomittee (RSRS) the evaluation of the safety aspects of new experiments and all changes to the facility that may be necessitated by the requirements cf the experiments and that may I
have safety significance. When experiments contain substances that ir-i radiation in the reactor can convert into a material with significant 12 1
Amendment No.16 l - = = = = = =
- - === =
-