- 05000348/LER-1985-016, :on 851002,plant Experienced Electrical Shorts Between Conductors in GE Series 100 Low Voltage Control Electrical Containment Penetration Modules.Caused Attributed to Separated Adjacent Connectors + (ML20133H493)
- IR 05000313/1985015 + (ML20133H494)
- ML20133H495 + (ML20133H495)
- ML20133H496 + (ML20133H496)
- ML20133H497 + (ML20133H497)
- ML20133H498 + (ML20133H498)
- ML20133H499 + (ML20133H499)
- 05000352/LER-1985-073, :on 850911,reactor Scrammed on Low Level Due to Feedwater Pump Trip on Low Suction Pressure & Isolation Signal Occurred.Caused by Loss of Condensate Pump B.Reactor Stabilized Using Trip Procedures T-99 & 100 + (ML20133H500)
- ML20133H501 + (ML20133H501)
- ML20133H502 + (ML20133H502)
- 0CAN088509, Responds to NRC Re Violations Noted in Insp Repts 50-313/85-15 & 50-368/85-16.Corrective Actions:Procedure 2203.09, Fire Protection Sys Annunciator Corrective Action, Rev 0 Revised + (ML20133H503)
- ML20133H504 + (ML20133H504)
- ML20133H506 + (ML20133H506)
- 05000277/LER-1985-018-01, :on 850912,reactor Water Cleanup Sys Inboard & Outboard Suction Valves Closed Due to High Flow Isolation Signal.Caused by Too Rapid Opening of Demineralizer Outlet Valve.Operator Instructed on Proper Procedures + (ML20133H507)
- ML20133H509 + (ML20133H509)
- ML20133H510 + (ML20133H510)
- ML20133H511 + (ML20133H511)
- ML20133H514 + (ML20133H514)
- ML20133H515 + (ML20133H515)
- ML20133H516 + (ML20133H516)
- ML20133H518 + (ML20133H518)
- ML20133H519 + (ML20133H519)
- ML20133H520 + (ML20133H520)
- 05000259/LER-1985-028-01, :on 850706,standby Gas Treatment Sys Train C Declared Inoperable.Caused by Failure of Charcoal Bed Heater High Temp Cutout Switch.Defective Switch Replaced & Train C Returned to Svc + (ML20133H522)
- 05000281/LER-1985-018-01, :on 850911,turbine Trip/Reactor Trip Occurred Due to Low Condenser Vacuum Signal.Caused by Operator Inadvertently Closing Four Condenser Inlet Valves While Throttling Four Condenser Outlet Valves + (ML20133H523)
- ML20133H525 + (ML20133H525)
- ML20133H526 + (ML20133H526)
- 05000316/LER-1984-032, :Between 841206 & 17,nine Events Occurred Involving Inability to Perform Hourly Insp of Inoperable Fire Assemblies.Caused by Coordination Problems W/ Implementation of Fire Watch Program + (ML20133H530)
- 05000316/LER-1985-027-01, :on 850911,determined That Fire Rating of Wall Separating Unit 1 & 2 Essential Svc Water Pump Rooms Not Consistent W/App R Requirements.Caused by Open Penetrations. Fire Watch Established & Penetrations Sealed + (ML20133H531)
- ML20133H532 + (ML20133H532)
- ML20133H533 + (ML20133H533)
- ML20133H535 + (ML20133H535)
- 05000361/LER-1985-045, :on 850909,discovered That Position Verification Not Performed at Scheduled Time for Control Element Assembly Calculator 2 on 850815.Caused by Personnel Error.Notation Included in Surveillance Log + (ML20133H536)
- ML20133H537 + (ML20133H537)
- ML20133H538 + (ML20133H538)
- 05000267/LER-1985-009, :on 850603,Loop 1 Automatic Shutdown Initiated by Plant Protective Sys.Caused by Short of Intermodular Connections Between Two Loop Trouble Logic Modules. Connections Repaired + (ML20133H539)
- ML20133H540 + (ML20133H540)
- 05000267/LER-1985-015, :on 850903,circulator a Trip on High buffer- mid-buffer Differential Pressure Occurred.Caused by Abnormal Cycling of Bearing Water Main Drain Control Valve.Valve Positioner Replaced + (ML20133H542)