Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20104B104 + (ML20104B104)
- RBG-19915, Interim Deficiency Rept DR-213 Re Pressure Setting on Safety Relief Valves for Air Start Sys Air Receivers on HPCS Diesel Generator Supplied by Ge.Next Rept Will Be Provided by 850306 + (ML20104B120)
- ML20104B121 + (ML20104B121)
- NRC-92-0111, Forwards Rev 6 to Radiological Emergency Response Preparedness Plan. Rev Clarifies Conditions & Indications in Table D-1 Re Clarification of Emergencies & Modifies Text to Reflect NRC-approved Amend 82 to TSs Issued 920609 + (ML20104B122)
- RBG-19914, Interim Deficiency Rept DR-274 Re Field Wiring to Asco & Target Rock Corp Solenoid Valves.Next Rept Anticipated by 850227 + (ML20104B138)
- ML20104B146 + (ML20104B146)
- ML20104B147 + (ML20104B147)
- ML20104B148 + (ML20104B148)
- ML20104B151 + (ML20104B151)
- ML20104B154 + (ML20104B154)
- ML20104B157 + (ML20104B157)
- ML20104B161 + (ML20104B161)
- ML20104B169 + (ML20104B169)
- ML20104B171 + (ML20104B171)
- ML20104B172 + (ML20104B172)
- ML20104B174 + (ML20104B174)
- 05000352/LER-1984-035, :on 841216,prior to Initial Criticality, Spurious Isolation of Reactor Water Cleanup Sys Occurred. Caused by Steam Leak Detection Sys Temp Switch Trip. Isolation Reset + (ML20104B177)
- ML20104B178 + (ML20104B178)
- ML20104B181 + (ML20104B181)
- 05000382/LER-1984-002, :on 841226,surveillance Not Performed for 11 Fire Doors Since 841218.Four Addl Doors Found Unverified as Operable.Caused by Incorrect Rev to Procedure.Procedure Revised & Reviewed by Personnel + (ML20104B185)
- ML20104B186 + (ML20104B186)
- ML20104B189 + (ML20104B189)
- 05000395/LER-1984-052, :on 841226,discovered Two Leads Associated W/ Turbine Trip Circuitry Lifted.Cause Unknown.Event Currently Under Review + (ML20104B191)
- ML20104B192 + (ML20104B192)
- ML20104B195 + (ML20104B195)
- ML20104B196 + (ML20104B196)
- ML20104B204 + (ML20104B204)
- ML20104B209 + (ML20104B209)
- ML20104B221 + (ML20104B221)
- ML20104B223 + (ML20104B223)
- ML20104B226 + (ML20104B226)
- ML20104B230 + (ML20104B230)
- 05000458/LER-1992-015, :on 920808,RWCU Sys Isolated Due to Failure of Temp Switch & Personnel Error.Malfunctioning Switch Replaced & Satisfactorily Tested + (ML20104B231)
- 05000458/LER-1992-013, :on 920730,determined That Surveillances Not Performed on Automatic Wet Pipe Sprinkler Sys.Caused by Incorrect Interpretation of Scope & Applicability of TS 4.7.6.2.c.3.STP-251-3601 Will Be Revised + (ML20104B237)
- ML20104B238 + (ML20104B238)
- ML20104B243 + (ML20104B243)
- ML20104B249 + (ML20104B249)
- 05000361/LER-1984-076, :on 841222,containment Purge Isolation Sys Train a Actuated Spuriously Due to Electrical Noise Spikes on Containment Area Radiation Monitor 2RT-7856.Cause Under Investigation + (ML20104B257)
- ML20104B260 + (ML20104B260)
- ML20104B266 + (ML20104B266)
- 05000361/LER-1984-081, :on 841223,both Supply Breakers to Auxiliary Relay Panel 2L-034 Opened.Cause Under Investigation. Personnel Counseled to Identify Appropriate Precautions During Clearance Planning Stage + (ML20104B267)
- 05000325/LER-1984-018-01, :on 841226,common Control Bldg Emergency Air Filtration Sys Train 2A Automatically Initiated.Caused by Spurious Actuation of Fire Detector in Shift Operating Supervisor Ofc Due to Tobacco Smoke + (ML20104B281)
- ML20104B284 + (ML20104B284)
- ET-NRC-92-3743, Forwards Info Re Insp Test Analyses & Acceptance Criteria for AP600 Design,Consisting of Class 1E Dc & UPS Sys, Containment Sys,Onsite Standby Power Sys,Passive Core Cooling Sys & Protection & Safety Monitoring Sys + (ML20104B289)
- 1CAN099201, Forwards Inservice Insp Summary Rept Arkansas Nuclear One, Unit 1,Outage:1R10. Forms NIS-2 Re Owners Rept for Repairs or Replacements Also Encl + (ML20104B292)
- 05000316/LER-1984-035-01, :on 841226,containment Insp Revealed body-to-bonnet Leakage on RCS Valve 2-RC-107 Loop 4.Caused by Carbon Steel body-to-bonnet Studs Severely Wasted Due to Corrosive Erosion.Studs Replaced + (ML20104B301)
- ML20104B302 + (ML20104B302)
- ML20104B304 + (ML20104B304)
- 05000456/LER-1992-009-06, :on 920812,1A & 2A DGs Declared Inoperable Due Procedural Deficiency.Special Test Procedures 92-047,048,049 & 050 Written & Performed.Abb Impell safety-related Surveillance Review Project Ongoing + (ML20104B312)
- ML20104B330 + (ML20104B330)
- ML20104B332 + (ML20104B332)