- ML20100F603 + (ML20100F603)
- RBG-19484, Part 21/Deficiency Rept DR-259 Re Separation of Underwriter Safety Device Co Part 13549 Split Terminal Blocks.Initially Reported on 841019.Corrective Action Not Determined.Next Rept Will Be Provided by 850103 + (ML20100F605)
- ML20100F606 + (ML20100F606)
- ML20100F613 + (ML20100F613)
- ML20100F616 + (ML20100F616)
- RBG-19483, Final Deficiency Rept DR-253 Re Limit Switch Compartment Covers on Limitorque SMB-000 Valve Operators.Initially Reported on 841016.Matl to Be Removed from Cover Internal Flanges to Allow Increase in Opening Size + (ML20100F617)
- ML20100F620 + (ML20100F620)
- ML20100F621 + (ML20100F621)
- ML20100F632 + (ML20100F632)
- ML20100F635 + (ML20100F635)
- 05000454/LER-1985-024, :on 850301,turbine/reactor Trip Occurred.Caused by Inability of Turbine electro-hydraulic Controller to Properly Position Governor Valves to Pick Up Generator Load. Load Vs Valve Position Curve Revised + (ML20100F643)
- RBG-19523, Final Part 21/deficiency Rept Re Thread Leakage in Rosemount Inc 1153 Series Pressure Transmitters.Initially Reported on 841026.New Procedure Recently Developed by Rosemount to Ensure Proper Curing of Neolube 100 Thread Sealant + (ML20100F644)
- ML20100F652 + (ML20100F652)
- 05000339/LER-1984-010-01, :on 841101,accumulator Isolation Valves a & B Inadvertently Opened When Breakers Energized.Caused by Solid Protection Sys Slave Relay in Deenergized State.Relay Actuated Into Correct Position + (ML20100F656)
- ML20100F664 + (ML20100F664)
- 05000289/LER-1984-004, Forwards Corrected LER 84-004-00 Re Misplugged Steam Generator Tubes.Rept Date Corrected & Licensee Contact Changed + (ML20100F667)
- ML20100F673 + (ML20100F673)
- 05000528/LER-1985-013, :on 850223,Train B Diesel Generator Started Inadvertently During Routine Surveillance Testing.Caused by Error in Surveillance Procedure for Testing Certain Subgroup Relay Contacts.Change Notice Issued + (ML20100F676)
- 05000289/LER-1984-004-03, :on 830602,discovered Tube A-134-74 Mistakenly Plugged in June 1983 While Tube A-135-72 Left Unplugged. Complete Photographic Reverification of All Plugged Tubes Performed + (ML20100F679)
- RBG-19485, Final Deficiency Rept DR-256 Re Var & Watt Scales in Standby Diesel Generators Supplied by Tdi.Initially Reported on 841019.Existing 0-5000 Kw & 0-5000 Kvar Scales in 1EGS*PNL1A & 1EGS*PNL1B to Be Replaced + (ML20100F680)
- ML20100F682 + (ML20100F682)
- ML20100F683 + (ML20100F683)
- 05000457/LER-1996-001-03, :on 960118,inadequate Control of Staged Roofing Matls Lead to Loss of Offsite Power Due to Loss of Both Unit 2 Station Auxiliary Transformers.Addressed Control of Staged Const Matls Onsite + (ML20100F690)
- ML20100F691 + (ML20100F691)
- ML20100F693 + (ML20100F693)
- ML20100F694 + (ML20100F694)
- ML20100F695 + (ML20100F695)
- 05000528/LER-1985-010, :on 850222,automatic Actuation of balance-of- Plant ESF Actuation Sys Occurred When Placing Train a Sequencer in Manual from Automatic Mode.Caused by Unique Circumstances Involving flip-flop U-14 + (ML20100F697)
- 05000322/LER-1985-008, :on 850227,emergency Diesel Generator 103 Automatically Started.Caused by Technician Error Coincident W/Reset of Ground Alarm Relay Tripping During Surveillance Procedure + (ML20100F698)
- RBG-19480, Interim Deficiency/Part 21 Rept Re Topaz Inverters Supplied by Ge.Initially Reported on 841019.Discussions W/Ge Currently Underway to Determine Appropriate Corrective Action.Next Rept Expected by 850122 + (ML20100F704)
- ML20100F705 + (ML20100F705)
- ML20100F708 + (ML20100F708)
- 05000269/LER-1985-003-02, :on 850222,emergency Safeguard Features Actuation Sys Setpoint Adjusted to 1,600 Psig.Caused by B&W Reanalysis of Small Break LOCA Transients,Per NUREG-0737. Setpoint Changes Initiated + (ML20100F710)
- ML20100F714 + (ML20100F714)
- ML20100F716 + (ML20100F716)
- ML20100F722 + (ML20100F722)
- ML20100F724 + (ML20100F724)
- 05000315/LER-1985-007-01, :on 850222,controlled Shutdown Initiated. Caused by Inoperable Control Room Emergency Ventilation Sys. Analysis of Potential Radiological Consequences of Operation at Higher Flow Rates Performed.Room Balanced + (ML20100F726)
- ST-HL-AE-1150, Interim Deficiency Rept Re Trapeze Type Support Assemblies. Initially Reported on 841022.Pipe Support Designs Will Be Reviewed to Identify Number of Supports Subj to Deficiency. Personnel Given Addl Training.Next Rept by 850322 + (ML20100F732)
- ML20100F733 + (ML20100F733)
- LIC-96-0016, Monthly Operating Rept for Jan 1996 for Fort Calhoun Station Unit 1 + (ML20100F736)
- ML20100F755 + (ML20100F755)
- ML20100F758 + (ML20100F758)
- ML20100F769 + (ML20100F769)
- ML20100F775 + (ML20100F775)
- RBG-19496, Interim Deficiency Rept DR-206 Re Lubricant in Two Fuel Pool Cooling Pumps & Motors.Next Rept Will Be Provided by 850124 + (ML20100F803)
- ML20100F806 + (ML20100F806)
- 05000483/LER-1985-010, :on 850331,ESFs Actuated Due to Low Steam Generator Levels.Caused by nonsafety-related 120-volt Ac Instrument Bus Deenergized Due to Faulty Transformers. Transformers Replaced + (ML20100F807)
- ML20100F809 + (ML20100F809)
- ML20100F810 + (ML20100F810)
- ML20100F825 + (ML20100F825)