List of results
- 05000388/LER-1984-008-01, :on 840527,turbine Bypass Valve 1 Failed to Close Below Open Position,Resulting in Reactor Protection Sys Manual Scram.Caused by Chipping Hammer Wedged Between Bypass Valve Seat & Valve Disc.Disc Replaced + (ML20092P380)
- ML20092P381 + (ML20092P381)
- ML20092P385 + (ML20092P385)
- ML20092P386 + (ML20092P386)
- NRC-84-0098, Submits Response to IE Bulletin 84-02 Re Relay Failures in GE Type Hfa Relays Containing Lexan/Nylon Coils.Rework Plans Issued to Replace Coils or Relays in Entirety.Plans Implemented & Required Replacements Completed + (ML20092P389)
- ML20092P401 + (ML20092P401)
- ML20092P405 + (ML20092P405)
- ML20092P409 + (ML20092P409)
- ML20092P412 + (ML20092P412)
- ML20092P413 + (ML20092P413)
- ML20092P414 + (ML20092P414)
- ML20092P424 + (ML20092P424)
- ML20092P425 + (ML20092P425)
- ML20092P427 + (ML20092P427)
- ML20092P447 + (ML20092P447)
- ML20092P448 + (ML20092P448)
- ML20092P450 + (ML20092P450)
- ML20092P453 + (ML20092P453)
- ML20092P458 + (ML20092P458)
- ML20092P473 + (ML20092P473)
- ML20092P478 + (ML20092P478)
- L-84-135, Responds to NRC Re Violations Noted in IE Insp Repts 50-335/84-09 & 50-389/84-12.Corrective Actions:Util Preparing Instructions for Temporary Storage Files to Meet QA Manual Requirements + (ML20092P491)
- ML20092P498 + (ML20092P498)
- DCL-84-248, Notifies of Completion of Fixes for safety-related Masonry Walls,Per IE Bulletin 80-11.Existing as-built Condition Would Not Preclude Addl Mod.No Addl Fixes Necessary Based on Analysis for Line Break & Jet Impingement + (ML20092P503)
- ML20092P504 + (ML20092P504)
- ML20092P506 + (ML20092P506)
- ML20092P508 + (ML20092P508)
- ML20092P513 + (ML20092P513)
- ML20092P515 + (ML20092P515)
- 05000272/LER-1984-013-01, :on 840602,power Interrupted Between 500 Kv Yard & 13 Kv Bus,Resulting in Loss of Onsite Power to 4 Kv Group & Vital Busses.Caused by Operator Error.Individual Counseled & Reprimanded for Actions + (ML20092P516)
- ML20092P521 + (ML20092P521)
- ML20092P530 + (ML20092P530)
- ML20092P533 + (ML20092P533)
- ML20092P535 + (ML20092P535)
- ML20092P537 + (ML20092P537)
- ML20092P539 + (ML20092P539)
- ML20092P543 + (ML20092P543)
- AECM-84-0339, Forwards Response to Jacksonians United for Livable Energy Policies 10CFR2.206 Petition,Per DG Eisenhut 840530 Request. Response Filed Per 10CFR50.54(f).Petition Should Be Denied in Entirety + (ML20092P544)
- ML20092P545 + (ML20092P545)
- B11247, Forwards Summary of 840614 Meeting W/S&W & Structural & Geotechnical Engineering Branch in Response to Structural Audit Confirmatory Items 41 & 15 + (ML20092P546)
- ML20092P547 + (ML20092P547)
- ML20092P549 + (ML20092P549)
- RBG-18116, Interim Deficiency Rept DR-75 Re Ghosh-Wilson Computer Program Used in Reactor Bldg Hydraulic Analysis.Next Rept Will Be Provided by 841130 + (ML20092P550)
- ML20092P551 + (ML20092P551)
- ML20092P554 + (ML20092P554)
- ML20092P555 + (ML20092P555)
- 05000263/LER-1984-020, :on 840530,Channels a & B Reactor Bldg Ventilation Wide Range Gas Monitors Tripped Due to Low Sample Flow.Caused by Plugged Sample Filters.Sample Flows Will Be Checked Once Per Shift During Outage + (ML20092P556)
- ML20092P557 + (ML20092P557)
- 05000311/LER-1984-015, :on 840530,reactor Tripped from 10% Power During Shutdown.Caused by Conservative Setpoint Value & Excessively Large Reset Deadband of Intermediate Range High Flux Trip Bistables.Setpoint Reset + (ML20092P559)
- ML20092P560 + (ML20092P560)
- ML20092P561 + (ML20092P561)