Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 0CAN059102, 1990 Annual Environ Radiological Monitoring Rept for Arkansas Nuclear One,Units 1 & 2 + (ML20091A409)
- 3F0591-05, Responds to NRC Re Violations Noted in Insp Rept 50-302/91-01.Corrective Actions:Removal & Replacement of Lifted Lead Documented Prior to Leaving Area & Walkdowns of Cable Spreading Room & Relay Racks Initiated + (ML20091A411)
- ML20091A422 + (ML20091A422)
- ML20091A430 + (ML20091A430)
- 05000263/LER-1978-013-03, /03L-0:on 780719,steam Leak in 90 Degree Elbow on Turbine Main Steam Bypass Header Drain Line to Condenser. Caused by Erosion.Restricting Orifice,Leaking Elbow & Addl Piping & Elbows to Be Inspected & Replaced + (ML20091A434)
- 05000263/LER-1978-015-03, /03L-0:on 780805,one APRM Scram Trip Setting at Four to Five Percent Low.Caused by Large Power Shape Changes Resulting in LPRM Output Changes.Gain Setting Corrected.W/ + (ML20091A441)
- ML20091A442 + (ML20091A442)
- 05000263/LER-1978-014-01, /01T-0:on 780728,CRD 30-47 Delayed Approx 1.4 Before Scramming.Disc in Scram Pilot Valve Solenoid Plunger Broken Into Several Pieces,Wedging & Preventing Valve from Venting Air on Scram Valves + (ML20091A449)
- ML20091A452 + (ML20091A452)
- 05000263/LER-1978-012-03, /03L-0:on 780616,lightning Storm Resulted in Plant Substation Lockouts Deenergizing Auxiliary Reserve Transformer.Relay Failed Due to Short Circuit Failure of Zener Diode in Trip Pulse Isolator Output + (ML20091A454)
- 05000263/LER-1978-010-03, /03L-0:on 780605,CRD 06-19 Delayed for Indefinite Period of Time.Caused by Buna N Disc in Scram Pilot Solenoid Plunger Broken in Several Pieces.Plunger Including Disc Replaced + (ML20091A460)
- ML20091A464 + (ML20091A464)
- 05000263/LER-1978-008-03, /03L-0:on 780525,inlet Air Heater Operating at Reduced Capacity Due to Fuse Failure.Fuse Block & Fuses Replaced in Kind + (ML20091A468)
- 05000263/LER-1978-009-03, /03L-0:on 780525,trip of Essential MCC B33A Supply Breaker 52-304 Resulted in Operation in Degraded Mode Permitted by Various Lco.Cause Unknown.Evaluation Continuing + (ML20091A470)
- 05000263/LER-1978-011-01, /01T-0:on 780606,four of Six APRM Scram Trip Settings Three to Four Percent Low.Aprm Calibr at 50% Power. Gain Settings Corrected + (ML20091A472)
- 05000263/LER-1978-007-03, /03L-0:on 780508,steam Leak Discovered in 45 Degree Elbow on HPCI Steam Supply Line Drain Line to Condenser.Caused by Erosion.Temporary Clamp Repair Made + (ML20091A474)
- ML20091A492 + (ML20091A492)
- ML20091A497 + (ML20091A497)
- ML20091A502 + (ML20091A502)
- ML20091A505 + (ML20091A505)
- ML20091A506 + (ML20091A506)
- ML20091A507 + (ML20091A507)
- RBG-36-637, Responds to NRC Ltr Re Violations Noted in Insp Rept 50-458/91-24.Corrective Actions:Developed Engineering Dept Procedure EDP-ME-27 to Provide Methodology to Feed Back Info from Diagnostic Testing & Maint + (ML20091A511)
- ML20091A517 + (ML20091A517)
- ML20091A523 + (ML20091A523)
- ML20091A524 + (ML20091A524)
- ML20091A525 + (ML20091A525)
- ML20091A527 + (ML20091A527)
- ML20091A529 + (ML20091A529)
- W3P84-1353, Forwards Clarifications to FSAR Chapter 14 Re Startup Test Program.Understands Clarifications Acceptable to NRC + (ML20091A533)
- ML20091A534 + (ML20091A534)
- ML20091A535 + (ML20091A535)
- ML20091A536 + (ML20091A536)
- ML20091A542 + (ML20091A542)
- ML20091A544 + (ML20091A544)
- ML20091A548 + (ML20091A548)
- ML20091A549 + (ML20091A549)
- ML20091A551 + (ML20091A551)
- ML20091A553 + (ML20091A553)
- ML20091A554 + (ML20091A554)
- RBG-17-827, Final Deficiency Rept DR-129 Re Agastat Relays w/CR0095 Bases Supplied by Ge.Condition Determined Not Reportable Under 10CFR50.55(e) + (ML20091A556)
- ML20091A558 + (ML20091A558)
- ML20091A564 + (ML20091A564)
- ML20091A567 + (ML20091A567)
- ML20091A571 + (ML20091A571)
- ML20091A574 + (ML20091A574)
- ML20091A575 + (ML20091A575)
- ML20091A586 + (ML20091A586)
- 05000374/LER-1984-016, :on 840423,Div 2 Reactor Water Cleanup High Ambient Temp Isolation Signal Received.Cause Unknown. Reactor Water Cleanup Rooms Checked for Leaks & Caution Card Placed by Div 2 Switches to Warn of Problem + (ML20091A587)
- ML20091A588 + (ML20091A588)
- ML20091A591 + (ML20091A591)