Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20082M043 + (ML20082M043)
- ML20082M057 + (ML20082M057)
- ML20082M066 + (ML20082M066)
- ML20082M089 + (ML20082M089)
- ML20082M111 + (ML20082M111)
- ML20082M117 + (ML20082M117)
- ML20082M120 + (ML20082M120)
- ML20082M124 + (ML20082M124)
- RC-95-0094, Monthly Operating Rept for Mar 1995 for Virgil C Summer Nuclear Station + (ML20082M126)
- ML20082M127 + (ML20082M127)
- ML20082M165 + (ML20082M165)
- 05000456/LER-1991-008-05, :on 910729,scaling Deficiency of Over Temp Delta Temp Occurred.Caused by Preservice Design Error. Initial Assessment of Similiar Scaling Deficiencies of Other Reactor Trip Protection Completed + (ML20082M171)
- 05000445/LER-1995-001-01, :on 950319,time Limit for TS Action Statement Requirements Exceeded When CR Radiation Monitor Was Out of Svc.Reemphasized Mgt Expectations + (ML20082M173)
- ML20082M176 + (ML20082M176)
- ML20082M191 + (ML20082M191)
- ML20082M192 + (ML20082M192)
- ML20082M194 + (ML20082M194)
- ML20082M195 + (ML20082M195)
- L-91-225, Forwards Changes to Rev 0 to Physical Security Plan,Per Discussions W/Nrc During Preoperational Insp of Security Sys.Encl Withheld (Ref 10CFR2.790(a)(3) & 73.21) + (ML20082M202)
- ST-HL-AE-3864, Forwards Response to NRC Re Violations Noted in Insp Repts 50-498/91-17 & 50-499/91-17 on Inadequate Access Control of Personnel & Packages.Response Withheld + (ML20082M211)
- ML20082M213 + (ML20082M213)
- NRC-91-0107, Forwards Fermi 2 Nuclear Power Plant Semiannual Radioactive Effluent Release Rept,Jan-June 1991. No Instances of Unmonitored or Unplanned Radioactive Releases from Site Noted During Reporting Period + (ML20082M221)
- ML20082M223 + (ML20082M223)
- ML20082M226 + (ML20082M226)
- GO2-83-109, Final Deficiency Rept,Condition 274 Re Excessive Gapping Between Pipe Support baseplates.Fifty-nine of 2,299 Baseplates Require Rework to Correct Deficient Baseplate Gap + (ML20082M228)
- ML20082M231 + (ML20082M231)
- ML20082M233 + (ML20082M233)
- ML20082M235 + (ML20082M235)
- ML20082M240 + (ML20082M240)
- JAFP-91-0539, Ja Fitzpatrick Effluent & Waste Disposal Semiannual Rept, Jan-June 1991 + (ML20082M242)
- ML20082M246 + (ML20082M246)
- 05000348/LER-1991-008, :on 910802,automatic Reactor Trip Occurred Due to Loss of Power to Reactor Coolant Pump Breaker Position. Caused by Personnel Error.Personnel Involved Counseled & Event Included in Next Cycle + (ML20082M247)
- ML20082M248 + (ML20082M248)
- ML20082M255 + (ML20082M255)
- ML20082M265 + (ML20082M265)
- 05000275/LER-1983-025-03, /03L-0:on 831021,steam Generator Blowdown Tank Vent Gross Activity Monitor RM-27 Failed Downscale While in svc.RM-27 Failed as Result of Random Failure of U-2 Bistable Multivibrator.Bistable Replaced + (ML20082M266)
- ML20082M268 + (ML20082M268)
- ML20082M269 + (ML20082M269)
- NRC-95-0033, Forwards Response to Re Violations Noted in Insp Rept 50-341/95-03.Corrective Actions:Set multi-discipline Task Force to Evaluate Repetitive Failures of Ite MCC Auxiliary Contacts & Barton Differential Pressure Switches + (ML20082M272)
- ML20082M273 + (ML20082M273)
- ML20082M278 + (ML20082M278)
- ML20082M280 + (ML20082M280)
- ML20082M285 + (ML20082M285)
- ML20082M287 + (ML20082M287)
- ML20082M291 + (ML20082M291)
- ML20082M295 + (ML20082M295)
- ML20082M299 + (ML20082M299)
- ML20082M301 + (ML20082M301)
- ML20082M308 + (ML20082M308)
- ML20082M309 + (ML20082M309)
- 05000440/LER-1995-003, :on 950323,loss of Safety Sys Function Occurred.Caused by Inoperable RHR Snubbers.Installed Pool Swell Shields on Three RHR Snubbers During RFO4 + (ML20082M310)