Er. closure 1 to Document Control Letter 1SP 900004-2 Page 1 PROPOSED TECHNICAL SPECIFICATION CHANGE - TSP 900004-2 VIRGIL C. SUMMER NUCLEAR STATION 1

LIST OF AFFECTED PAGES Page j

i

'6-3 i

l l

i i

i l

t i

I i

i L

L i

i

{

l i

PDR ADOCK 0S000395 9109050030 910826 P

PDR

. t t

. -. ~..,. -,.... -. ~. _

-_-,___._____..m__,-.-.

--.,---,cm.-,.--

l t

e ADMINISTRAflVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG) f FUNCTION l

6.2.3.1 The ISEC shall function to examine plant operating characteristics, NRC issuances, industry advisories, Licensee Event Reports and other sources of plant design and operating experience information, ihcluding plants of i

similar design, which may indicate areas for improving plant safety.

C0HP051T10N 6.2.3.2 The ISEG shall be composed of a multi-disciplined dedicated onsite group with a minimum assigned complement of five engineers or appropriate specialists.

L RESPON5!BILITIES i

6.2.3.3 The ISEG shall be responsible for maintaining surveillance of plant activities to provide independent verification" that these activities are performed correctly and that human errors are reduced as much as practical.

AUTHORITY 6.2.3.4 The 15EG shall make detailed recommendations for procedure revisions, i

equipment modifications, maintenance activities, operations activities or other s

means of improving plant safety to the General Manager, Nuclear Safety.

l 6.2.4 SHIFT TECHN! CAL ADVISOR The Shift Technical Advisor shall provide technical support to the Shift Supervisor in the areas of thermal hydraulics, reactor engineering and plant analysis with regard to the safe operation of the unit, s

6.3 UNIT STAFF QUAllFICATIONS 6.3.1 Each member of the unit staf f shall meet or exceed the minimum Qualifica-tions of ANSI N18.1-1971 for comparable positions and tne supplemental require-1 ments specified in Sections A and C of Enclosure 1 of the March 28, 1980 letter to all licensees as clarified in NUREG-0737, Section 1.A.2,1, except for the Associate Manager, Health Physics who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975, the Shif t Technical Advisor w50 shall meet or exceed the qualifications referred to in Section 2.2.1.b of Enclosure I of the October 30, 1979 NRC letter to all operating nuclear power plants, and the members of tne Independent Saf ety Engineering Group, each of whom shall have a Bachelor of Science degree or registered Professional Engineer and at least two years experience in their field.

At least one year experience shall be in the nuclear field.

6.4 TRAINING

((cafah l

6.4.1 A retraining and replacement training program for nit staff shall f

be main gta'ned and shall meet or exceed the requirements and recommendations of Sec t iont 4. M 5. 5.pf AN5I 3.1-1981.jand 10 C'9 55.53, e, w -siied io in Appendix 3A cf the fins! 55 f ety Ansi-3i 34perW Also, A n*Tsainin a+tcl-

/)qdtetonmfMssirdn earrr jGr Y fnAtud k**ifQ.54s4 aioWedaM fh1M 7MA OL fMR e 46fassmalt of McfA$5Sy (c)e& 55,3/ (a) (4),

)

  • Not responsible for sign-off function.

SUMMER - UNIT 1 6-3 Amendment No.77,yE,79 r

f i

{

1 a

r f

I ADMINISTRATIVE CONTROLS f

6.2.3 INDEPENDENT SAFETY ENGINEER]NG GROUP (!$EG)

FUNC110N 6.2.3.1 The ISEG shall function to examine plant operating characteristics, NRC issuances, industry advisories Licensee Event Reports and other sources of plant design and operating experience information, including plants of similar design, which may indicate areas for improving plant safety.

[

t COMPOSITION 6.2.3.2 The ISEG shall be_ composed of a multi-disciplined dedicated c-

{

group with a minimum assigned complement of five engineers or appropriate specialists.

I RESPONSLBJLITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of plant activities to provide independent verification

  • that these activities are performed correctly and that human errors are reduced as much as practical.

j AUTHORITY 6.2.3.4 The ISEG shall make detailed recommendations for procedure i

revisions, equipment modifications, maintenance activities, operations activities or other means of improving plant safety to the General Manager, t

Nuclear Safety.

6.2.4 SHIFT TECHNIC 4L ADVISOR i

The Shift Technical Advisor shall provide technical support to the Shift Supervisor in the areas of thermal hydraulics, reactor engineering and plant analysis with regard to the safe operation of the unit.

l 6.3 UNIT STAFF OVALIFICATIONS 6.3.1 Each member of the unit staff shall meet or exceed the minimum f

qualifications of ANSI N18.1-1971 for comparable positions and the supplemental requirements specified in. Sections A and C of Enclosure 1 of the March 28, 1980 letter to all licensees as clarified In NUREG-0737, Section i

I.A.2.1, except for the Associate Manager, Health Physics who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975, the Shif t Tecnnical Advisor who shall meet or exceed the qualifications referred to in Section 2.2.1.b of Enclosure ! of the October 30, 1979 NRC letter to all 1

operating nuclear power plants, and the members of the Independent Safety Engineering Group, each of whom shall have a Bachelor of Science degree or i

registered Professional Engineer and at least two years experience in their field. At least one year experience shall be in the nuclear field.

-j i

6.4 TRAINING i

6.4.1 A retraining and replacement training program for the non-licensed unit staff shall be maintained and shall meet or exceed the requirements and recommendations of Section 5.5.2 of ANSI 3.1-1981. Also, a retraining and replacement training program for the licensed unit staff shall be maintained anc shall meet or exceed the requirements of 10CFR55.59(c) and 55.31(a)(4).

  • Not responsible for sign-off function.

SUMMER - UNIT 1 6-3 AMENDMENT N0.