- 05000370/LER-1983-068-03, /03L-0:on 831025,pressurizer Level Instrumentation Channel II Exceeded Max Allowed Tolerance of 40%.Caused by Component Failure.Leaks Repaired by Tightening Fittings on Impulse Lines + (ML20082H678)
- ML20082H681 + (ML20082H681)
- ML20082H683 + (ML20082H683)
- 05000366/LER-1983-118-03, /03L-0:on 831026,personnel Received Start Failure on Diesel Generator 2C & Discovered Diesel Generator Voltage Could Not Be Manually Adjusted.Caused by Leaking in-line Check Valve.Check Valve Replaced + (ML20082H688)
- ML20082H692 + (ML20082H692)
- ML20082H695 + (ML20082H695)
- ML20082H697 + (ML20082H697)
- ML20082H703 + (ML20082H703)
- ML20082H705 + (ML20082H705)
- ML20082H708 + (ML20082H708)
- ML20082H710 + (ML20082H710)
- PLA-1955, Ro:On 830828,ECCS Acutuated,Resulting in Injection of Water Into Rcs.Protective Functions Actuated in Conservative Manner.As of 830828,usage Factor Nozzles Is Less than .70 + (ML20082H714)
- ML20082H718 + (ML20082H718)
- 05000348/LER-1983-076-03, /03L-0:on 831022,monthly Hydrogen Analyzer Surveillance of Hydrogen Recombiner 2B Not Current,Per Tech Specs.Caused by Failure to Check Surveillance Record. Recombiner Secured on 831022.Personnel Counseled + (ML20082H720)
- ML20082H721 + (ML20082H721)
- ML20082H728 + (ML20082H728)
- NRC-83-0060, Interim Significant Deficiency Rept 83-12 Re Class IE Electrical Cable Trays & non-Category I Seismic HVAC Ductwork within Seismic Category I Bldgs.Initially Reported 831025.Next Rept Due in 60 Days.Also Reportable Per Part 21 + (ML20082H732)
- ML20082H735 + (ML20082H735)
- ML20082H738 + (ML20082H738)
- ML20082H739 + (ML20082H739)
- ML20082H742 + (ML20082H742)
- ML20082H745 + (ML20082H745)
- ML20082H748 + (ML20082H748)
- ML20082H749 + (ML20082H749)
- ML20082H750 + (ML20082H750)
- ML20082H752 + (ML20082H752)
- ML20082H753 + (ML20082H753)
- ML20082H755 + (ML20082H755)
- 05000366/LER-1983-119-03, /03L-0:on 831025,channel a of Torus Water Level & Drywell Pressure Recorder Determined Inoperable Due to False Torus High Water Level Alarm.Caused by Channel a Pen Binding.Pen Carriage Adjusted + (ML20082H757)
- ML20082H760 + (ML20082H760)
- 05000366/LER-1983-104-03, /03L-0:on 831025,refueling Floor Vent Exhaust Radiation Monitor 2D11-K611D Malfunctioned.Caused by Failed Circuit Board & Sensing Element.Failed Components Replaced + (ML20082H766)
- BECO-83-280, Responds to IE Bulletin 83-06 Re Nonconforming Matls Supplied by Tube-Line Corp Facilities.Procurement Activities Not Indicated by Comprehensive Search of Records Mgt Database + (ML20082H771)
- ML20082H774 + (ML20082H774)
- 05000412/LER-1991-003-01, :on 910724,ESF Actuation Trip Occurred During Surveillance Testing of Containment Air Recirculation Fan. Caused by Personnel Lifting Wrong Lead to Fan.Fan Restarted & Operator Counseled & Received Reprimand + (ML20082H775)
- ML20082H776 + (ML20082H776)
- ML20082H780 + (ML20082H780)
- ML20082H783 + (ML20082H783)
- 05000369/LER-1991-009-02, :During Wk of 910708,discovered That Gain Setting to Average Reactor Coolant Temp Input Would Cause Process Control Equipment to Reach Hardware Limit.Caused by Design Defect.Resistors Changed + (ML20082H786)
- ML20082H789 + (ML20082H789)
- ML20082H790 + (ML20082H790)
- ML20082H791 + (ML20082H791)
- 05000289/LER-1991-002-02, :on 910724,reactor Tripped on Low RCS Pressure Due to Control Rod Group 7 Dropping Into Reactor Core.Caused by Personnel Error & Equipment Failure.Components Repaired & Maint Personnel Trained + (ML20082H794)
- ML20082H797 + (ML20082H797)
- ML20082H798 + (ML20082H798)
- ML20082H804 + (ML20082H804)
- 05000305/LER-1983-028-03, /03L-0:on 831028,charging Pump 1B Removed from Svc & Isolated Due to Hairline Crack Discovered in Discharge Head.Caused by Matl Fatigue at Socket Weld Due to Vibration. Piping Cut Out.New Section Welded in Place + (ML20082H805)