List of results
- ML20082H406 + (ML20082H406)
- ML20082H409 + (ML20082H409)
- ML20082H413 + (ML20082H413)
- ML20082H417 + (ML20082H417)
- ML20082H418 + (ML20082H418)
- 05000366/LER-1983-122-03, /03L-0:on 831104,while Performing HPCI Steam Line Delta P Instrument Ft & C Procedure,Hpci Steam Line Flow High Switch Found Actuating Above Tech Spec Limit.Caused by Setpoint Drift.Switch Calibr + (ML20082H420)
- ML20082H424 + (ML20082H424)
- 05000280/LER-1983-048-03, /03L-0:on 831024,discharge Pressure of Charging Pump B Pump CC Decreased to Point Which Automatically Started Redundant Pump.Caused by Closed Valve LCV-CC-001 + (ML20082H430)
- ML20082H441 + (ML20082H441)
- 05000220/LER-1983-033-03, /03L-0:on 831018,during Normal Operation,Visual Insp of Snubber 39-4S-21 Revealed Oil Reservoir Indicated off-scale Toward Low End.Snubber Removed & Proven Operable. Snubber Replaced 831019 to Insure Operability + (ML20082H444)
- ML20082H445 + (ML20082H445)
- 05000278/LER-1983-015-03, /03L-0:on 831013,during HPCI Sys Testing,Both HPCI Turbine Exhaust Rupture Discs Failed Due to High Pressure.Hpci Declared Inoperable.Caused by Water in Exhaust Line During Turbine Start.Disc Replaced + (ML20082H446)
- ML20082H448 + (ML20082H448)
- ML20082H451 + (ML20082H451)
- ML20082H452 + (ML20082H452)
- 05000219/LER-1983-021-03, /03L-0:on 831012,loss of Main Bus 1A & Emergency Bus 1C Rendered One Standby Gas Treatment Sys Train Inoperable.Stack Gas Sampling Capability Lost for Approx 3 Had Pump a Shutdown Due to Loss of Power + (ML20082H454)
- ML20082H459 + (ML20082H459)
- ML20082H471 + (ML20082H471)
- ML20082H475 + (ML20082H475)
- ML20082H486 + (ML20082H486)
- ML20082H492 + (ML20082H492)
- ML20082H501 + (ML20082H501)
- ML20082H504 + (ML20082H504)
- ML20082H506 + (ML20082H506)
- ML20082H508 + (ML20082H508)
- ML20082H516 + (ML20082H516)
- 05000369/LER-1983-107-01, /01T-0:on 831111,while in Mode 1,door Seals on Reactor Bldg Side Door Inadvertently Deflated While Auxiliary Bldg Side Door Open.Caused by Procedural Deficiency.Procedural Step Added + (ML20082H518)
- ML20082H519 + (ML20082H519)
- ML20082H520 + (ML20082H520)
- ML20082H522 + (ML20082H522)
- 05000324/LER-1983-091-03, /03L-0:on 831026,isolation Valve E51-F043C Would Not Reopen.Caused by Broken Bakelite Nipple in Valve Control Switch,Model EF4.Switch Module B47173 Replaced & Valve F043C Cycled & Returned to Svc + (ML20082H524)
- 05000305/LER-1983-026-03, /03L-0:on 831025,while Performing Monthly Pump & Valve Surveillance Test,Status Light on RHR Pump 1A Failed to Light When Pump Started.Caused by Failure of Stationary Auxiliary Switch to Fully Close + (ML20082H526)
- ML20082H528 + (ML20082H528)
- ML20082H529 + (ML20082H529)
- ML20082H532 + (ML20082H532)
- 05000280/LER-1983-049-03, /03L-0:on 831102,performance of Heat Tracing Periodic Test Revealed Ampere Readings for Heat Tracing Circuits 23A,24C,22A & 24D Not within Test Limits.Caused by Excessive Heat.Heat Tracing Replaced + (ML20082H540)
- ML20082H545 + (ML20082H545)
- 05000366/LER-1983-120-03, /03L-0:on 831029,personnel Discovered Reactor Vessel Water Level Recorder 2B21-R615 Not Indicating Accurate Level Per Conditions.Caused by Loose Clutch.Screws Holding Clutch in Place Replaced & Tightened + (ML20082H551)
- U-602437, Monthly Operating Rept for Mar 1995 for Clinton Power Station,Unit 1 + (ML20082H552)
- ML20082H554 + (ML20082H554)
- ML20082H555 + (ML20082H555)
- ML20082H561 + (ML20082H561)
- BSEP-95-0170, Monthly Operating Repts for Mar 1995 for Brunswick Steam Electric Plant + (ML20082H568)
- ML20082H571 + (ML20082H571)
- ML20082H575 + (ML20082H575)
- 3F0891-05, Forwards Fitness for Duty Program Performance Data for Jan-Jun 1991 + (ML20082H578)
- ML20082H586 + (ML20082H586)
- ML20082H589 + (ML20082H589)
- ML20082H590 + (ML20082H590)
- 05000272/LER-1983-049-03, /03L-0:on 831017,foreign Matl Discovered in Safety Injection Pump 11 Oil Reservoir,Rendering Pump Inoperable.Caused by Pump leak-off Backed Up in Catch Trough Due to Plugged Drain Line + (ML20082H594)
- ML20082H602 + (ML20082H602)