Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000311/LER-1983-053-99, /99X-0:on 830812,while Increasing RCS Pressure to 2,000 Psig,Both Pressurizer Spray Valves Opened & RCS Pressure Started to Decrease.Probably Caused by Pressure Control manual-auto Loading Station + (ML20082A522)
- ML20082A530 + (ML20082A530)
- ML20082A532 + (ML20082A532)
- B10927, Provides Summary of Reevaluations of LOCA Based on Identification of Several Assemblies Containing Leaking Fuel Pins & fuel-related Damage Which Necessitated Rev to Cycle 6 Core Loading Pattern + (ML20082A548)
- ML20082A549 + (ML20082A549)
- ST-HL-AE-1022, Interim Deficiency Rept Re Anchor Bolt Defects. Presentation Documenting Specific Program & Schedule for Completion of Activities Required to Resolve Issue Encl. Final Rept Expected on 840401,per 830919 Meeting + (ML20082A554)
- HL-4813, Annual Environ Surveillance Rept + (ML20082A558)
- HL-4799, Forwards Request for Relief from ASME XI Code Case N-416-1. Util Proposes to Augment Alternative Tests by Performing an Addl Surface Exam on Root Pass Layer + (ML20082A563)
- ML20082A571 + (ML20082A571)
- ST-HL-AE-5056, Discusses Rev to SER for Amends 71 & 60 to Plant TS + (ML20082A584)
- ML20082A587 + (ML20082A587)
- ML20082A616 + (ML20082A616)
- 05000311/LER-1983-052-03, /03L-0:on 830928 & 1005,130-ft Elevation Containment Air Lock Failed to Meet Requirements for Routine Surveillance Testing of Air Lock Door Seals.Possibly Caused by Improper Test Methods.Training Upgraded + (ML20082A617)
- ML20082A619 + (ML20082A619)
- ML20082A625 + (ML20082A625)
- ML20082A628 + (ML20082A628)
- 05000311/LER-1983-055-03, /03L-0:on 831004,during Routine Power Operation, Steam Generator Pressure Channel II Instrument 21 Indicated Excessively Different than Redundant Channels.Cause Unknown. Minor Calibr Performed + (ML20082A632)
- ML20082A639 + (ML20082A639)
- ML20082A640 + (ML20082A640)
- ML20082A642 + (ML20082A642)
- RBG-41258, Informs That Util Cannot Complete Physical Security Plan Commitmment Re UPS to Security Sys Until Refueling Outage 6, as Discussed in Attachment,Per Response to Violation Noted in Insp Rept 50-458/93-05.Attachment Withheld + (ML20082A644)
- 05000317/LER-1983-059-03, /03L-0:on 831011,chemical Vol Control Sys Chemical Isolation Signal for Channel Zf Discovered Inoperable. Caused by Room Pressure Transmitter Out of Calibr. Transmitter Recalibr + (ML20082A645)
- ML20082A651 + (ML20082A651)
- ST-HL-AE-5042, MSSV & Pressurizer Safety Valve Setpoints Discovered Outside Required Tolerances + (ML20082A652)
- ML20082A654 + (ML20082A654)
- ML20082A663 + (ML20082A663)
- 05000498/LER-1995-003, :on 950227,MSSV & Pressurizer Safety Valve Setpoint Found Outside Required Tolerances.Caused by Setpoint Drift.Adjusted Lift Settings of Seven MSSV to Be within Required Allowable Tolerances + (ML20082A672)
- ML20082A682 + (ML20082A682)
- 05000317/LER-1981-022-03, ESF Actuation Sys Degraded Voltage Relay 127/B-11-H Found Inoperable.Caused by Relay Output Contact Binding.Relay Repaired + (ML20082A692)
- ML20082A693 + (ML20082A693)
- ML20082A697 + (ML20082A697)
- ML20082A704 + (ML20082A704)
- ML20082A709 + (ML20082A709)
- ML20082A711 + (ML20082A711)
- ML20082A717 + (ML20082A717)
- ML20082A719 + (ML20082A719)
- ML20082A721 + (ML20082A721)
- ML20082A724 + (ML20082A724)
- ML20082A727 + (ML20082A727)
- 05000334/LER-1995-004, :on 950301,five MSSV Determined by Testing to Be Outside TS 3.7.1.1 Tolerance of +1%-3%.Caused by Vendor Provision in Incorrect Mean Seat Area Data Used.Made Adjustments on Six Affected Safety Valves + (ML20082A729)
- ML20082A732 + (ML20082A732)
- 3F0395-21, Advises of Organizational Change Affecting Responsibility for in-processing/access Control to Plant,Unit 3 + (ML20082A734)
- ML20082A735 + (ML20082A735)
- ML20082A739 + (ML20082A739)
- 0CAN039507, Forwards Proposed TS Changes Re ECP + (ML20082A741)
- ML20082A748 + (ML20082A748)
- ML20082A749 + (ML20082A749)
- 05000317/LER-1983-058-03, /03L-0:on 831004 & 12,discovered That 12 Solid Radwaste Pumps Could Not Be Stopped from Control Room to Open Contact on Local Control Switch.Caused by High Resistance Across Handswitch Contacts 3 & 4 + (ML20082A751)
- 05000267/LER-1983-036-03, /03L-0:on 830928,emergency Feedwater Supply Header to Loop I Helium Circulator Water Turbine Drives Isolated Twice to Perform Maint on Two Leaking Header Safety Valves & One Pressure Control Valve.Valves Repaired + (ML20082A753)
- B15166, Submits Suppl to Original Amend Request on 950124 Re Acceptance Criterion for Measured RCS Flow Rate for four- Loop Operation + (ML20082A759)
- ML20082A761 + (ML20082A761)