- ML20081D491 + (ML20081D491)
- 05000336/LER-1995-005, :on 950211,inadvertent Actuation of ESF Equipment Occurred.Caused by Wiring Error During Const of Cabinets Combined W/Plant Mod.Verified All Cabinets & Actuation Relay Wiring for Correct Polarity + (ML20081D496)
- ML20081D497 + (ML20081D497)
- ML20081D498 + (ML20081D498)
- ML20081D499 + (ML20081D499)
- ML20081D503 + (ML20081D503)
- NG-95-0908, Monthly Operating Rept for Feb 1995 for DAEC + (ML20081D505)
- ML20081D507 + (ML20081D507)
- ML20081D508 + (ML20081D508)
- 05000369/LER-1983-047-01, /01T-0:on 830929,two Scheduled Auxiliary Bldg Electrical Penetration Room Fire Watch Patrols Not Performed.Caused by Personnel Error.Personnel Counseled + (ML20081D510)
- ULNRC-03164, Discusses Rod Control Sys Failure & Withdrawal of Rod Cluster Control Assemblies Per 10CFR50.54 + (ML20081D516)
- ML20081D517 + (ML20081D517)
- PLA-1883, Interim Deficiency Rept Re Electrical Sys Separation Inside Multiple Div Pull Boxes & Junction Boxes.Walkdown/Insp Results Being Analyzed.Final Rept Will Be Submitted in Nov 1983 + (ML20081D522)
- ML20081D523 + (ML20081D523)
- ML20081D524 + (ML20081D524)
- ML20081D525 + (ML20081D525)
- ML20081D528 + (ML20081D528)
- ML20081D532 + (ML20081D532)
- ST-HL-AE-5038, Requests That Distribution Lists for Transmittals Re Plant, Units 1 & 2 Be Changed as Listed + (ML20081D534)
- 05000277/LER-1983-022-03, /03L-0:on 830907,recirculation Motor Generator Set Room & Recirculation Motor Generator Set Lube Oil Pump Room Sprinkler Sys Did Not Automatically Actuate.Caused by Coil Failure.Proper Dc Coils Installed + (ML20081D536)
- 05000244/LER-1983-028-03, /03L-0:on 830916,small Leak Discovered in Weld on Outlet Side of Boric Acid to FCV-110A Manual Shutoff Valve V-354.Caused by Lack of Fusion in Weld at Point Where Weld Pass Overlapped.Area Ground Out & Rewelded + (ML20081D537)
- 05000387/LER-1983-138-03, /03L-0:on 830923,during Semiannual Functional Check of Fire Protection Ionization Detectors,Traversing in-core Probe Ball Valves Prevented from Performing Containment Isolation Function + (ML20081D540)
- 05000324/LER-1983-081-03, /03L-0:on 830930,isolating Function of TIP C Guide Tube Primary Containment Isolation Ball Valve Found Inoperable When Machine Probe Would Not Fully Retract from Core.Investigation Will Be Performed + (ML20081D543)
- ML20081D548 + (ML20081D548)
- 05000389/LER-1983-062-03, /03L-0:on 830922,while at 50% Power,Control Element Assembly 18 Dropped to Core Bottom.Control Element Aligned W/Group within 7 Minutes.Cause Not Determined. Vendor Review in Progress + (ML20081D553)
- ML20081D554 + (ML20081D554)
- ML20081D556 + (ML20081D556)
- 05000338/LER-1983-063-03, /03L-0:on 830928,post-reactor Shutdown Specific Activity Samples of RCS Indicated Dose Equivalent I-131 Level Greater than Tech Spec Limit.Caused by post-trip Enhancing Release of Fission Fragments + (ML20081D557)
- ST-HL-AE-5030, Forwards Response to NRC Re Violations Noted in Insp Repts 50-498/94-19 & 50-499/94-19.Corrective Actions:Inservice Test Procedure for Reactor Makeup Water Pumps Has Been Approved & Issued for Use + (ML20081D562)
- ML20081D573 + (ML20081D573)
- ST-HL-AE-5031, Failure to Meet Requirements of TS Due to Failure to Perform ASME Section XI Test on Standby DG Starting Air Receiver Inlet Check Valves + (ML20081D574)
- 05000327/LER-1983-128-03, /03L-0:on 830925,containment Ventilation Radiation Monitor 1-RM-90-106B for Gaseous Activity Declared Inoperable.Caused by High Radiation Relay Unplugged from Terminal.Relay reinstalled.W/831024 + (ML20081D578)
- ML20081D580 + (ML20081D580)
- 05000325/LER-1983-048-03, /03L-0:on 831005,RTGB Suppression Pool Level Indicator 1-CAC-LR-2602 Indicated 1-1/2 Inches Lower than Actual Level.Caused by Loose Negative Input Lead.Lead Connected to LR-2602 Terminal Block + (ML20081D581)
- 05000260/LER-1983-056-03, /03L-0:on 830920,while Performing SI 4.2.B-57, Discovered That RHR Pump 2C Cooler Fan Would Not Operate. Caused by GE CR124CO28 Overload Relay Tripping.Overload Relay Replaced + (ML20081D582)
- ML20081D584 + (ML20081D584)
- 05000338/LER-1983-066-03, /03L-0:on 830929,during Startup,Six Individual Rod Position Indicators Deviated from Group Demand Position by Greater than 12 Steps.Caused by Instrument Drift. Indicator Channels Recalibr + (ML20081D598)
- W3P83-3545, Comments on NRC Sept 1983 Evaluation of Need for Rapid Depressurization Capability for C-E Plants.No Technical Basis Supports Requirement for Porvs.Review,Rev & Detailed Comments Requested + (ML20081D599)
- 05000289/LER-1983-027-03, /03L-0:on 830916,during Performance of Emergency Sequence & Power Transfer test,make-up Pump MU-P-1C Tripped After 4160-volt IE Bus Loaded on Diesel Generator.Caused by Variable Time Delay.Relay Replaced + (ML20081D600)
- ML20081D604 + (ML20081D604)
- ML20081D609 + (ML20081D609)
- 05000280/LER-1983-042-03, /03L-0:on 830917,svc Water Pump 1-SW-P-10A Developed Low Discharged Pressure (9-10 Psig),Causing 1-SW-P-10B to auto-start.Caused by Clogged Suction Strainer. Strainer Cleaned + (ML20081D612)
- ML20081D619 + (ML20081D619)
- 05000298/LER-1983-015-03, /03L-0:on 830923,pressure Switch NBI-PS-102A Failed to Perform High Pressure Safety Trip of Reactor Recirculation Pump A.Caused by Relay Failure to Energize. Relay Replaced + (ML20081D623)
- NRC-83-0055, Forwards Addl Info for Instrumentation & Control Sys Branch Review of Remote Safe Shutdown Capabilities,Per NRC 831005 Request.Remote Shutdown Capabilities of Util Design Not Altered by Backfits Required to Conform to App R + (ML20081D625)
- 05000321/LER-1983-090-03, During Procedure HNP-1-3405,RCIC Declared Inoperable.Caused by Setpoint Drift & Component Failure.Low Bearing Oil Pressure Switch Recalibr & Turbine Exhaust Switches Dried Out + (ML20081D633)
- ML20081D634 + (ML20081D634)
- JAFP-83-1031, Notifies That Review of Purchase Orders for 1981 to Present Revealed No Tube-Line Supplied ASME Code Matls Ordered or Received,In Response to IE Bulletin 83-06 + (ML20081D638)
- 05000327/LER-1983-116-03, /03L-0:on 830924,computer P-250 Failed,Rendering Reactor Coolant Subcooling Margin Monitor Inoperable.Caused by Power Spike to Disc Due to Bus Transfers Made in 500-kW Switchgear.Computer Restarted + (ML20081D644)
- ML20081D655 + (ML20081D655)
- 05000366/LER-1983-080-03, /03L-0:on 830928,following Manual Scram,Standby Gas Treatment Fan 2A Did Not Auto Start & Certain Group II & V Inboard Isolation Valves Did Not Auto Close.Caused by Defective Relay.Relay Replaced + (ML20081D661)