Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20080L180 + (ML20080L180)
- ML20080L192 + (ML20080L192)
- ML20080L195 + (ML20080L195)
- ML20080L197 + (ML20080L197)
- 05000254/LER-1995-003-02, :on 950125,determined That TIP Sys Pci Ball Valves on Units 1 & 2 Outside Design Basis Due to Incomplete Review of Sys Circuitry.Mod to Unit 2 TIP Sys Will Be Installed During Next Unit 2 Refueling Outage + (ML20080L202)
- ML20080L204 + (ML20080L204)
- ML20080L205 + (ML20080L205)
- RBG-15-982, Interim Deficiency Rept DR-92.Investigation Incomplete.Next Rept Will Be Provided by 831208 + (ML20080L209)
- ML20080L212 + (ML20080L212)
- ML20080L213 + (ML20080L213)
- ML20080L215 + (ML20080L215)
- 05000368/LER-1983-037-03, /03L-0:on 830816,during Mode 1 Operation, Degradations in Fire Doors 257 & 270 Observed.Caused by Relocation of Signs & Security Equipment Installation & Mods.Degradations Repaired + (ML20080L221)
- ML20080L224 + (ML20080L224)
- ML20080L232 + (ML20080L232)
- A830020, Provides List of Valves Performing Pressure Isolation Function Between High & Low Pressure Sys for RCPB Per NRC 830718 Request + (ML20080L241)
- ML20080L243 + (ML20080L243)
- 0CAN028406, Responds to Generic Ltr 84-01 Re NRC Use of Terms Important to Safety & safety-related.Participation in Discussion Will Be Through Steering Committee & Chairman of Util Safety Classification Group + (ML20080L250)
- ML20080L255 + (ML20080L255)
- 05000498/LER-1995-001, :on 950124,experienced Reactor Trip Due to low- Low SG Level on 1C SG After Loss of MFW Pump 13.Caused by Failed Thrust Bearing Wear Probe Assembly.Thrust Bearing Wear Probe Assembly on MFW Pump 13 Replaced + (ML20080L256)
- RC-95-0042, Submits Four Controlled Copies of Amend 34 to Physical Security Plan.Encl Withheld + (ML20080L258)
- ML20080L261 + (ML20080L261)
- ML20080L273 + (ML20080L273)
- ML20080L274 + (ML20080L274)
- 05000368/LER-1983-039-03, /03L-0:on 830825,leak Found in Weld of Pressure Sensing Line for Middle Seal of Reactor Coolant Pump.Caused by Weld Crack Due to Vibration.Line W/Cracked Weld Replaced. Mod Planned + (ML20080L275)
- 05000361/LER-1983-118-03, /03L-0:on 830911,containment Isolation Valve 2HCV-9945 Found Locked Open.Caused by Valve Incorrectly Positioned on 830906.Isolation Valve Returned to Proper Position.Appropriate Disciplinary Action Taken + (ML20080L277)
- ML20080L285 + (ML20080L285)
- 05000327/LER-1983-112-01, /01T-0:on 830911,both Trains of Actuation Logic for Reactor Trip Made Inoperable When Reactor Trip Breaker Undervoltage Coils Jumpered Out.Caused by Procedural Error. Procedure Revised + (ML20080L286)
- ML20080L291 + (ML20080L291)
- ML20080L293 + (ML20080L293)
- ML20080L297 + (ML20080L297)
- ML20080L299 + (ML20080L299)
- 05000282/LER-1995-001-01, :on 950125,determined That Safeguards Traveling Screen Declared Inoperable on 950121 Due to Personnel Error Reportable.Standing Instrument Calibr Procedures Will Be Reviewed + (ML20080L305)
- ML20080L311 + (ML20080L311)
- ML20080L319 + (ML20080L319)
- ML20080L323 + (ML20080L323)
- RBG-15-986, Final Deficiency Rept DR-114 Re Welds in Radial Rebar Anchor Ring for Shield Bldg Roof.Condition Not Reportable Per 10CFR50.55(e) + (ML20080L326)
- ML20080L329 + (ML20080L329)
- ML20080L334 + (ML20080L334)
- ML20080L336 + (ML20080L336)
- ML20080L340 + (ML20080L340)
- RBG-16-986, Forwards Response to Geosciences Branch Question 231.15 Re 41 Unidentified Seismic Reflection Profile Lines within 5 Miles of Site.Response Clarifies Info Submitted on 840120 & Will Be Incorporated Into FSAR + (ML20080L345)
- ML20080L348 + (ML20080L348)
- ML20080L351 + (ML20080L351)
- ML20080L359 + (ML20080L359)
- ML20080L367 + (ML20080L367)
- ML20080L373 + (ML20080L373)
- ML20080L383 + (ML20080L383)
- ML20080L384 + (ML20080L384)
- ML20080L386 + (ML20080L386)
- 05000255/LER-1983-061-03, /03L-0:on 830910,11 & 16,several Hourly Fire Tours in safety-related Areas Not Completed within Required Period.Caused by Personnel Error.Fire Tours Reestablished + (ML20080L389)
- ML20080L394 + (ML20080L394)