N C:mm:nw :lth Edis:n

/

) one Fjrst Na_tjonal Plaza. Chicago. I,hnois

(

) Address Reply to Post Office Box 767

/ Chicago. tilinois 60690 September 22, 1983 Mr. James G.

Keppler, Regional Administrator

- Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Quad Cities Station Unit 2 Core Spray Sparger Inspection in Accordance with I.E.

Bulletin 80-13 NRC Docket No. 50-265 Reference (a):

J.

G.

Kepp1Lr letter to Cordell Reed dated May 12, 1980.

Dear Mr. Keppler:

As required by Item 1 of the subject Bulletin, the Unit 2 Core Spray Spargers were visually inspected on September 10, 1983, utilizing a remote underwater TV camera.

The segment of piping between the inlet nozzle and vessel shroud was also inspected on each Core Spray loop.

Adequate resolution was obtained with the underwater TV camera.

No evidence of cracks was identified during the conduct of the above described inspection.

Please direct any questions you may have regarding this matter to this office.

Very trul

yours, B.

Rybak Nuclear Licensing Administrator 1m cc:

Director of I&E NRC Resident Inspector - Quad Cities 7346N 0309300181 830922 SEP 2 61983 PDR ADOCK 05000265 G

PDR AS// l O