- 05000244/LER-1983-026-01, /01T-0:on 830915,boric Acid Storage Tank Solution Concentration Less than Tech Spec Requirements.Caused by Leakage of Reactor Makeup Water Through Valve FCV-110A & Check Valve 355.Sampling Increased + (ML20078M814)
- ML20078M821 + (ML20078M821)
- 05000271/LER-1983-022-03, /03L-0:on 830913,reactor Water Cleanup Sys Outboard Isolation Valve Malfunctioned.Caused by Faulty Torque Switch in Valve Operator.Torque Switch Replaced & Sys Tested Satisfactorily + (ML20078M822)
- BSEP-94-0485, Responds to NRC Re Violation Noted in Insp Repts 50-324/94-31 & 50-325/94-31.Corrective Actions:Ts Equipment List Revised,Safety Analysis for Field Revs Revised & Issued & Training Conducted for Appropriate Personnel + (ML20078M823)
- 05000366/LER-1983-088-03, /03L-0:on 830922,during Control Locked Valve Procedure HNP-514,noninterruptable Instrument Air Supply Valves 2P52-F459 & F460 Found Unlocked.Caused by Personnel Error.Valves Locked in Position + (ML20078M826)
- 05000366/LER-1983-061-03, /03L-0:on 830921,during RCIC Turbine Exhaust Diaphragm Pressure Instrument Procedure HNP-2-3414, Connection Line Inadvertently Broke Off RCIC Turbine D Exhaust Diaphragm Pressure Switch + (ML20078M828)
- U-602410, Expresses Understanding That NRC Will Continue Review & Evaluation of Util Request for Permanent Change to Drywell Bypass Leakage Test Frequency,Requested by 940812 & 1014 Ltrs + (ML20078M833)
- ML20078M839 + (ML20078M839)
- A09738, Provides Response & Explanation Re Radiation Monitor Calibration Sticker & Surveillance Procedures + (ML20078M840)
- ULNRC-03108, Special Rept 94-05:on 941111,discovered Unit Vent - High Range Noble Gas Monitor (GTRE0021B) Inoperable for Greater than Seven Days.Caused by Misunderstanding of Channel 216 Failure Characteristics.Monitor Declared Operable on 941118 + (ML20078M843)
- ML20078M844 + (ML20078M844)
- ML20078M849 + (ML20078M849)
- ML20078M854 + (ML20078M854)
- B15046, Responds to RAI Re GL 89-19 Recommendations for Operator Training & SG Overfill Procedures + (ML20078M860)
- 2CAN119406, Application for Amend to License NPF-6,adding Note to Surveillance Requirement 4.4.5.0 Which Clarifies Requirements for Special SG Insps + (ML20078M862)
- 05000272/LER-1983-041-03, /03L-0:on 830915,discovered Containment Air Particulate Detector Filter Failure Alarm Illuminated.Caused by Inadequate Supply of Filter Paper.New Filter Paper Installed + (ML20078M865)
- ML20078M867 + (ML20078M867)
- ML20078M872 + (ML20078M872)
- ML20078M875 + (ML20078M875)
- A09588, Discusses Review of Issues at Facility Re Steam Generator Blowdown Radiation Monitor + (ML20078M876)
- ML20078M877 + (ML20078M877)
- ML20078M884 + (ML20078M884)
- ML20078M898 + (ML20078M898)
- 05000389/LER-1983-053-03, /03L-0:on 830909,while in Hot Shutdown,Containment Pressure Exceeded 0.4 Psig Limit.Caused by Heatup & High Pressure.Pressure Released by Purge After Obtaining Waste Gas Release Permit + (ML20078M899)
- ML20078M904 + (ML20078M904)
- 05000366/LER-1983-086-03, /03L-0:on 830919,during Performances of Procedure HNP-2-3101,reactor Vessel Water low-low Level Instruments 2B21-NO25B,Switch 2 & 2B21-NO25A,Switch 1,failed to Actuate Properly.Caused by Setpoint Drift + (ML20078M920)
- 05000387/LER-1983-128-03, /03L-0:on 830913,reactor Bldg Zone III Ventilation Sys Tripped & Automatically Restarted.Caused by Spurious Actuation of Differential Pdshh 17501B Switch.Pneumatic Instruments Replaced + (ML20078M926)
- ML20078M942 + (ML20078M942)
- ML20078M969 + (ML20078M969)
- ML20078M975 + (ML20078M975)
- ML20078M978 + (ML20078M978)
- ML20078M981 + (ML20078M981)
- ML20078M997 + (ML20078M997)
- ML20078M998 + (ML20078M998)
- GO2-20-055, Level of Financial Protection - Annual Reporting Requirement + (ML20078N002)
- ML20078N014 + (ML20078N014)
- ML20078N016 + (ML20078N016)
- ML20078N028 + (ML20078N028)
- 05000271/LER-1983-023-03, /03L-0:on 830923,health Physics Sampling Program Revealed High Co-60 Concentration at North Storm Drain Outfall.Caused by Low Level Airborne Releases from Turbine Bldg Roof Vents.Sample Point Added + (ML20078N035)
- 05000277/LER-1983-014-03, /03L-0:on 830812,control Room Fire Barrier Discovered W/O Fire Damper in One Ventilation Duct Penetration.Caused by Damper Not Incorporated Into Original Ventilation Sys Installation.New Damper on Order + (ML20078N044)
- ML20078N051 + (ML20078N051)
- 05000387/LER-1983-121-03, /03L-0:on 830902,average Power Range Monitor Flow Biased Simulated Thermal Power - Upscale Scram & Neutron Flux - Upscale Control Rod Block Trip Setpoints Higher than Tech Spec Limit.Caused by Power Peaking + (ML20078N061)
- AECM-83-0303, Provides Supplemental Final Response to Violation Noted in IE Insp Rept 50-416/83-12.Bechtel QA Evaluated & Verified That Corrective Actions Respond to Concerns Raised.All Corrective Actions Completed on 830607 + (ML20078N075)
- 05000272/LER-1983-040-03, /03L-0:on 830916,reactor Trip Breaker 1 post-maint Surveillance Not Completed within 1 H Interval.Caused by Addl Testing Incorporated Into Surveillance.License Change Request Will Be Submitted to Increase Interval + (ML20078N078)
- ML20078N082 + (ML20078N082)
- 05000324/LER-1983-054-03, Following High/Low Alarm Annunciation,Rtgb Suppression Pool Level Indicator 2-CAC-LI-2601-1,3 & 2-CAC-LI-3342 Levels Found Below Tech Spec Limit.Caused by Spraying Water + (ML20078N097)