- ML20078H337 + (ML20078H337)
- ML20078H349 + (ML20078H349)
- ML20078H352 + (ML20078H352)
- 05000316/LER-1983-088-03, /03L-0:on 830912,nonfunctional Fire Seal Discovered.Caused by Fire Seal Pulled While Installing Another Cable.Fire Seal Repaired & Contractor Personnel Retrained + (ML20078H359)
- 05000316/LER-1983-089-03, /03L-0:on 830915,west Containment Spray Pump Discharge Valve Position Lights Noted Out & Breaker Open. Cause Could Not Be Determined.No Corrective Action Planned + (ML20078H363)
- PY-CEI-NRR-1895, Informs of Rev of Commitment Made in Response to Violation Noted in Insp Rept 50-440/93-23 Re Periodic Testing of Emergency Facility HVAC Sys + (ML20078H365)
- 05000316/LER-1983-090-03, /03L-0:on 830920,during Surveillance Test on solid-state Protection Sys,Two Logic Positions Tested Unsatisfactorily.Caused by Defective Universal Card A-311. Logic Card Replaced + (ML20078H366)
- 05000316/LER-1983-091-03, /03L-0:on 830906,pressurizer Pressure Dropped Below Tech Spec Limit.Caused by Combination of Individual Pressurizer Heater Circuit Breakers Tripping & High Valve Seat Leakage.Load Reduced + (ML20078H371)
- ML20078H375 + (ML20078H375)
- 05000321/LER-1983-095-03, /03L-0:on 830913,during Hydrogen & Oxygen Analyzer Instrument Procedure,Analyzer a 1P33-N002A Found Out of Calibr.Caused by Instrument Drift.Analyzer Recalibr + (ML20078H382)
- ML20078H384 + (ML20078H384)
- ML20078H396 + (ML20078H396)
- ML20078H409 + (ML20078H409)
- ML20078H412 + (ML20078H412)
- NRC-94-0101, Forwards Proprietary Gec Document, Torsional Analysis of Fermi 2 Coupled Blade & Rotor Line. Document Related to Turbine Generator Evaluation as Result of 931225 Event.Encl Withheld (Ref 10CFR2.790) + (ML20078H413)
- AECM-83-0634, RO 83-087/0:on 830831,Fire Door 1A204 Blocked Open to Support Planned Maint Activities.Fire Watches Established Per Tech Specs Until Door Restored on 830910 + (ML20078H414)
- 05000338/LER-1983-058-03, /03L-0:on 830808,incorrect Alignment of Charging High Head Safety Injection Pump Breakers & Control Switches Discovered.Caused by Inadequate Procedural Guidance. Alignment Corrected + (ML20078H415)
- 05000362/LER-1983-067-03, /03L-0:on 830901,one-phase Trip of Supply Breaker for part-length Control Element Assembly (CEA) 32 Rendered CEA Incapable of Withdrawal.Caused by Failure of Circuitry Components.Components Replaced + (ML20078H434)
- ML20078H437 + (ML20078H437)
- AECM-83-0637, RO 83-086/0:on 830829,listed Fire Barriers Opened to Support Planned Maint Activities.Fire Watches Established & Barriers Restored + (ML20078H438)
- ML20078H441 + (ML20078H441)
- ML20078H446 + (ML20078H446)
- ML20078H453 + (ML20078H453)
- ML20078H457 + (ML20078H457)
- ML20078H458 + (ML20078H458)
- ML20078H459 + (ML20078H459)
- ML20078H470 + (ML20078H470)
- ML20078H477 + (ML20078H477)
- ML20078H480 + (ML20078H480)
- 05000302/LER-1983-036-01, /01T-0:on 830921,fuel Storage Pool Area Surveys Discovered Not Performed at Least Once Every 24 H from 830915-21.Caused by Personnel Error.Procedures Will Be Revised + (ML20078H482)
- ML20078H491 + (ML20078H491)
- ML20078H493 + (ML20078H493)
- ML20078H494 + (ML20078H494)
- ML20078H495 + (ML20078H495)
- ML20078H497 + (ML20078H497)
- ML20078H500 + (ML20078H500)
- ML20078H507 + (ML20078H507)
- ML20078H512 + (ML20078H512)
- ML20078H514 + (ML20078H514)
- 05000260/LER-1983-053-03, /03L-0:on 830907,during Normal Operation,While Performing Whole Core Low Power Range Monitor calibr,P-1 Indicated R Factor Less than Required.Caused by Uncalibr Monitor Due to Changes in Reactor Shape + (ML20078H519)
- ML20078H521 + (ML20078H521)
- ML20078H525 + (ML20078H525)
- ML20078H528 + (ML20078H528)
- ML20078H534 + (ML20078H534)
- ML20078H540 + (ML20078H540)
- L-83-511, Suppl to Final Deficiency Rept 82-014 Re Malfunctioning Shutdown Cooling Sys HX Bypass Valves.Valves Will Be Replaced W/Conventional Limitorque Operators Prior to Startup from First Refueling + (ML20078H564)
- ML20078H568 + (ML20078H568)
- ML20078H574 + (ML20078H574)
- 1CAN098312, Informs That Tech Specs for Low Temp Overpressurization Protection Sys Will Be Submitted by 831121,in Response to NRC 830826 Request for Submittal Schedule + (ML20078H575)
- ML20078H576 + (ML20078H576)
- ML20078H583 + (ML20078H583)