- ML20073C069 + (ML20073C069)
- ML20073C078 + (ML20073C078)
- ML20073C083 + (ML20073C083)
- ML20073C091 + (ML20073C091)
- ML20073C092 + (ML20073C092)
- ML20073C095 + (ML20073C095)
- ML20073C109 + (ML20073C109)
- 05000321/LER-1983-026, Forwards LER 83-026/03L-0 + (ML20073C117)
- 05000321/LER-1983-013, Forwards LER 83-013/03L-0 + (ML20073C131)
- ML20073C138 + (ML20073C138)
- ML20073C141 + (ML20073C141)
- 05000321/LER-1983-026-03, /03L-0:on 830303,during Performance of Procedure HNP-1-3304,HPCI Steam Line Pressure Switches E41-N001B&D Actuated Below Tech Spec Requirement.Caused by Switches Being Out of Calibr.Switches Recalibr + (ML20073C143)
- ML20073C144 + (ML20073C144)
- 05000321/LER-1983-013-03, /03L-0:on 830222,during Performance of HPCI Pump Operability Procedure,Hpci Turbine Exhaust Diaphragms Ruptured.Caused by Personnel Error.Hpci Valve & Diaphragms Repaired & Installed.Personnel Counseled + (ML20073C153)
- ML20073C162 + (ML20073C162)
- ML20073C164 + (ML20073C164)
- ML20073C168 + (ML20073C168)
- BSEP-83-1123, Forwards Monthly Operating Repts for Mar 1983 + (ML20073C183)
- ML20073C194 + (ML20073C194)
- ML20073C245 + (ML20073C245)
- ML20073C247 + (ML20073C247)
- ML20073C255 + (ML20073C255)
- ML20073C266 + (ML20073C266)
- ML20073C276 + (ML20073C276)
- ML20073C287 + (ML20073C287)
- ML20073C305 + (ML20073C305)
- HL-4693, Special Rept 1-94-001:on 940911,seven Days Elapsed Since Main Stack post-accident Effluent Monitoring Sys Declared Inoperable Due to Damage to Sys Electronics by Lightning. Sys Expected to Be Returned to Svc by 940921 + (ML20073C306)
- ML20073C311 + (ML20073C311)
- ML20073C313 + (ML20073C313)
- A09066, Submits Chronological Summary of Events Leading to Allegation RI-90-A-136 Re in-place Testing Process & Work on Flow Control Valve.Significant Discrepancies Noted Between Allegations & Util Documentation + (ML20073C315)
- ML20073C318 + (ML20073C318)
- A09076, Submits Results of Review of Allegation RI-90-A-144 Re Steam Jet Air Ejector Radiation Monitor RM 5099 + (ML20073C320)
- ML20073C325 + (ML20073C325)
- NRC-94-4305, Forwards Westinghouse Responses to NRC Requests for Addl Info on AP600 from Ltrs of 940429,0523,24,0615 & 0815. Responses Provided as Electronic Files Wordperfect 5.1 Format W/Kenyon Copy + (ML20073C332)
- A09163, Submits Results of Review of Allegations R1-90-A-0180 & RI-90-A-0202 Re Inoperability of wide-range Instruments & Annual Preventive Maint on Various Limitorque Operators + (ML20073C334)
- ML20073C335 + (ML20073C335)
- ML20073C336 + (ML20073C336)
- ML20073C343 + (ML20073C343)
- ML20073C348 + (ML20073C348)
- ML20073C354 + (ML20073C354)
- ML20073C358 + (ML20073C358)
- ML20073C360 + (ML20073C360)
- A09188, Submits Results of Review of Allegation R1-90-A-0206 Re Low Flow Setpoint on Standby Pump.Caused by Procedural Noncompliance.Valve Setpoint Change Processed + (ML20073C365)
- ML20073C366 + (ML20073C366)
- ML20073C367 + (ML20073C367)
- TXX-3654, Responds to Generic Ltr 83-10C Re Plan for Resolution of TMI Action Plan Item II.K.3.5, Automatic Trip of Reactor Coolant Pumps. Revised Westinghouse Criteria Will Ensure Continued Forced RCS Flow for Steam Generator Tubes + (ML20073C368)
- ML20073C375 + (ML20073C375)
- ML20073C376 + (ML20073C376)
- ML20073C377 + (ML20073C377)
- 05000254/LER-1994-009-06, :on 940823,omissions in Inventory & Leak Test Paperwork Discovered During Review of Inventory & Leak Test Program for Sealed Sources.All Sealed Sources That Required Leak Test But Missed Tested + (ML20073C379)
- A09187, Submits Results of Review of Allegation R1-90-A-0205 Re Oil Not Removed from Motor Prior to Removing Motor or Disconnecting Motor Leads.Procedure MP-272OC5 Will Be Clarified + (ML20073C384)