- ML20072F697 + (ML20072F697)
- 05000237/LER-1982-043-01, Sightglass Isolation & Vent Valves Reported Open W/No Indication of Excess Make Up. Caused by Operator Error.Valves Immediately Closed. Sightglass Isolation Valves Locked Closed + (ML20072F704)
- ML20072F709 + (ML20072F709)
- 05000316/LER-1983-022, Forwards LER 83-022/03L-0 + (ML20072F712)
- ML20072F725 + (ML20072F725)
- ML20072F733 + (ML20072F733)
- 05000327/LER-1983-029, Forwards LER 83-029/03L-0 + (ML20072F747)
- 05000327/LER-1983-029-03, /03L-0:on 830219,ice Condenser Lower Inlet Door Zone D Limit Switches Indicated Open Door.Caused by Misadjustment of Microswitch Limit Switch Model LSH1A for Ice Condenser Bays 9 & 11.Limit Switches Adjusted + (ML20072F755)
- 05000334/LER-1983-015-03, /03L-0:on 830524,during Normal Power Operation, Relay 5I-VD106X Experienced Spurious Actuation,Causing Inadvertent Isolation of Emergency Bus 1DF from Normal Supply.Caused by Personnel Error + (ML20072F758)
- 05000387/LER-1983-080-03, /03L-0:on 830513,setpoint for PDIS-E-11-INO19B (Shutdown Cooling High Flow) Found Out of Tolerance.Caused by Setpoint Drift.Switch Recalibr & Returned to Svc + (ML20072F760)
- 05000302/LER-1994-004, :on 940701,noticed That ATWS Turb AMSAC Low Flux Bypass Annunciator Began to Alarm Every Few Seconds Due to Personnel Error.Setpoints for ATWS-AMSAC Arming Reset & Surveillance Performed + (ML20072F770)
- ML20072F772 + (ML20072F772)
- 05000373/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl + (ML20072F778)
- 05000373/LER-1983-015-03, /03L-0:on 830217,while Testing Diesel Generator 1B Per LOS-DG-M3,diesel Tripped While Being Off Loaded.Diesel Restarted & Speed Varied Between 400 & 900 Rpm.Caused by Bad Connection at Run Solenoid.Connection Reconnected + (ML20072F796)
- PY-CEI-NRR-0053, Responds to Generic Ltr 83-18, NRC Review of BWR Owners Group Control Room Survey Program. Plant-specific Info to Be Addressed Listed + (ML20072F798)
- ML20072F799 + (ML20072F799)
- 05000219/LER-1994-011, :on 940718,discovered That Control Panels Er 8A & Er 8B Housing Control Logic for Portions of ADS & CSS Did Not Meet Seismic Criteria Due to Original Design.Seismic Plates Installed to Limit Control Panel Motion + (ML20072F801)
- ML20072F807 + (ML20072F807)
- ML20072F811 + (ML20072F811)
- 05000263/LER-1983-005, Forwards LER 83-005/03L-0 + (ML20072F818)
- 05000416/LER-1982-172-99, Penetration AE154C in Auxiliary Bldg Opened to Perform Planned Maint.Penetration Opened to Pull Cable Through.Limiting Condition for Operation Initiated & Hourly Fire Watch Established + (ML20072F823)
- ML20072F829 + (ML20072F829)
- 05000263/LER-1983-005-03, /03L-0:on 830216,RHR Pump 14 Made Inoperable to Investigate Head Capacity Reduction.Caused by Mophead in Pump Suction,Probably Entering RHR Sys During Maint or Const Projects.Mophead Removed + (ML20072F832)
- 05000318/LER-1983-028-03, /03L-0:on 830516,accumulator 12 on MSIV 21 Found to Have Ruptured Bladder.No Cause Stated.Accumulator Repaired & MSIV Declared Operable.Msiv 21,accumulator 5,will Be Replaced During Next Hot Shutdown + (ML20072F834)
- ML20072F835 + (ML20072F835)
- ML20072F846 + (ML20072F846)
- ML20072F849 + (ML20072F849)
- ML20072F850 + (ML20072F850)
- ML20072F863 + (ML20072F863)
- AECM-83-0340, RO 83-043/0:on 830503,smoke Detector N524E,in Zone 1-24 (Control Cabinet Room),Alarmed Continuously After Being Bumped by Maint Worker.Fire Detection Zone Declared Inoperable.Fire Watch Established.No Cause Found + (ML20072F867)
- ML20072F870 + (ML20072F870)
- ML20072F872 + (ML20072F872)
- 05000321/LER-1983-018, Forwards LER 83-018/03L-0 + (ML20072F873)
- 05000327/LER-1983-079-01, /01T-0:on 830607,notified by Nonconformance Rept SQNNEB8304 Re Possibility of Block Wall Failing During Tornado.Caused by Incorrect Loading Used in Original Calculations.Procedure Revised + (ML20072F874)
- ML20072F882 + (ML20072F882)
- ML20072F887 + (ML20072F887)
- 05000321/LER-1983-018-03, /03L-0:on 830216,reactor Water Conductivity Monitor Indicated Higher than Correct Reading Taken by Lab Personnel.Caused by Component Failure Due to Inadequate Flow to Instrument.Instrument Sample Line Cleaned + (ML20072F888)
- ML20072F907 + (ML20072F907)
- 05000336/LER-1983-001-04, /04T-0:on 830302,recorder Associated W/Liquid Radwaste Discharge Path Rjr 9129 Failed While in Mode 3 at 532 F.Caused by Stripped Gear on Drive Motor.Defective Gear & Motor Replaced + (ML20072F921)
- ML20072F922 + (ML20072F922)
- ML20072F923 + (ML20072F923)
- ML20072F925 + (ML20072F925)
- 05000281/LER-1983-007, Forwards LER 83-007/03L-0 + (ML20072F926)
- ML20072F932 + (ML20072F932)
- RBG-14-607, Interim Deficiency Rept DR-75 Re Error in Ghosh-Wilson Computer Program Used in Reactor Bldg Hydrodynamic Analysis. Corrected Analyses Resulted in Changes in G Values That Do Not Require Hardware Mods.Next Rept Expected by 830930 + (ML20072F933)
- ML20072F937 + (ML20072F937)
- 05000328/LER-1983-024, Forwards LER 83-024/03L-0 + (ML20072F939)
- 05000334/LER-1994-008-01, :on 940719,main Unit Transformer Initiated Immediate Unit 1 Generator/Turbine Trip.Caused by flash-over of Insulating Bushing on Unit 1 Main Unit Transformer.Main Unit Transformer Heat Detectors Replaced + (ML20072F946)
- 05000281/LER-1983-007-03, /03L-0:on 830217,operators Discovered Heat Tracing Panels 8 & 9 Circuit 2 & 13 Tagged Out & de-energized.Caused by Operator Improperly Performing Tagout Procedure.Circuits Energized & Verified Operable + (ML20072F949)
- ML20072F953 + (ML20072F953)
- ML20072F955 + (ML20072F955)