Amend 78 to License NPF-42,re Changes to TS to Revise TS Table 3.6-1, Containment Isolation Valves by Deleting Ref to Two Valves
ML20072F922
Person / Time
Site: Wolf Creek 
Issue date: 08/16/1994
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20072F924 List:
References
NUDOCS 9408240125
Download: ML20072F922 (7)


Text

..

    • "'c oq

.A E

UNITED STATES 3

- ^!

NUCLEAR REGULATORY COMMISSION k.....,/

wAssincron. o.c. rosss-cooi WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION DOCKET NO. 50-482 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 78 License No. NPF-42 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the Wolf Creek Generating Station (the facility) Facility Operating License No. NPF-42 filed by the Wolf Creek Nuclear Operating Corporation (the Corporation), dated April 19, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the-application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations D.

The issuance of this license amendment will not be inimical to the common' defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51' of the Commission's regulations and all applicable requirements have been satisfied.

  • 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-42 is hereby amended to read as follows:

2.

Technical Soecifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 78, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated in the license. The Corporation shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

The license amendment is effective as of its date of issuance and shall be implemented prior to startup from the seventh refueling outage.

FOR THE NUCLEAR REGULATORY COMMISSION ti $ h

,4W}~

Theodore R. Quay, Director Project Directorate IV-2 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

August 16, 1994

I ATTACHMENT TO LICENSE AMENDMENT N0. 7a FACILITY OPERATING LICENSE NO. NPF-42 DOCKET NO. 50-482 Replace the following pages of the Appendix A Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain marginal lines indicating the areas of change.

The corresponding overleaf pages are also provided to maintain document completeness.

REMOVE INSERT 3/4 6-24 3/4 6-24 3/4 6-25 3/4 6-25

e TABLE 3.6-1 (Continued)

CONTAINHENT ISOLATION VALVES MAXIMUM TYPE LEAK ISOLATION TIME PENETRATIONS VALVE NUMBER FUNCTION TEST REQUIRED (Seconds) 4.

Containment Purge Isolation (active) - (Continued)

V-160 GT HZ-11***

CTMT Mini-Purge C

3 Exh Inside CTMT Iso V-160 G" HZ-12***

CTMT Mini-Purge C

3 Exh Outside CTMT Iso 5.

Containment Purge Isolation (passive)

V-161 GT HZ-6***

CTMT S/D Purge C

10 Supply Outside CTMT Iso V-161 GT HZ-7***

CTMT S/D Purge C

10 Supply Inside CTMT Iso V-160 GT HZ-8***

CTMT S/D Purge C

10 Exh Inside CTMT Iso V-160 GT HZ-9***

CTMT S/D Purge C

10 Exh Outside CTMT Iso 6.

Remote Manual P-41 BB HV-8351A RCP A Seal Water C

N. A.

Supply P-22 BB HV-8351B RCP B Seal Water C

N.A.

Supply P-39 BB HV-8351C RCP C Seal Water C

N.A.

Supply P-40 BB HV 8351D RCP D Seal Water C

N.A.

Supply P-79 BB PV-8702A RCS Hot Leg 1 to RHR A

N.A.

Pump A Suction

      • The provisions of Specification 3.0.4 are not applicable provided the penetration 1

is isolated by two passive devices.

WDLF CREEK - UNIT 1 3/4 6-23

i i

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES MAXIMUM TYPE LEAK ISOLATION TIME PENETRATIONS VALVE NUMBER FUNCTION TEST RE0VIRED (Seconds) 6.

Remote Manual - (Continued)

P-52 BB PV-87028 RCS Hot leg 4 to RHR A

N.A.

Pump B Suction P-15 EJ HV-23**

PASS Sump Sample CTMT C

5 Iso P-15 EJ HV-25**

PASS Sump Sample CTMT C

5 Iso P-14 EJ HV-24**

PASS Sump Sample CTMT C

5 Iso P-14 EJ HV-26**

PASS Sump Sample CTMT C

5 Iso P-71 EF HV-31 ESW Supply To C

N.A.

Containment Coolers P-28 EF HV-32 ESW Supply To C

N.A.

Containment Coolers l

P-71 EF HV-33 ESW Supply To C

N.A.

Containment i

Coolers P-28 EF HV-34 ESW Supply To C

N.A.

l Containment l

Coolers l

P-73 EF HV-45 ESW Return From C

N.A.

Containment Coolers P-29 EF HV-46 ESW Return From C

N.A.

Containment Coolers I

    • The provisions of Specification 3.0.4 are not applicable.

l WOLF CREEK - UNIT !

3/4 6-24 Amendment No. 78 l

I l

.k.

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES MAXIMUM TYPE LEAK ISOLATION TIME PENETRATIONS VALVE NUMBER FUNCTION TEST RE0VIRED (Seconds) 6.

Remote Manual - (Continued) 1 P-73 EF HV-49 ESW Return From C

N.A.

Containment Coolers P-29 EF HV-50 ESW Return From C

N.A.

Containment Coolers P-74 EG HV-127*

CCW Supply to RCP C

N.A.

P-75 EG HV-130*

CCW Return From RCP C

N.A.

P-75 EG HV-131*

CCW Return From RCP C

N.A.

P-76 EG HV-132*

CCW Return From RCP C

N.A.

Thermal Barriers P-76 EG HV-133*

CCW Return from RCP C

N.A.

Thermal Barrier P-79 EJ HV-8701A RCS Hot Leg 1 to RHR A

N.A.

Pump A Suction P-52 EJ HV-8701B RCS Hot Leg 4 to RHR A

N.A.

Pump B Suction P-82 EJ HV-8809A RHR Pump A Cold Leg A

N.A.

Injection Iso Valve P-27 EJ HV-8809B RHR Pump B Cold Leg A

N.A.

Injection Iso Valve P-15 EJ HV-8811A CTMT Recirc Sump to A

N.A.

RHR Pump A Suction

]

i

  • These valves were assumsd to be closed during the accident analysis, and are normally closed but may be opened on an intermittent. basis under administrative control.

4 1

WOLF CREEK - UNIT 1 3/4 6-25 Amendment No. 78 4

ze

-r,--rc

-,e....,

-v-

,r---

W s

TABLE 3.6-1 (Continued)

CONTAINMENT ISOLATION VALVES l

MAXIMUM l

TYPE LEAK ISOLATION TIME PENETRATIONS VALVE NUMBER FUNCTION TEST REQUIRED (Seconds) 6.

Remote Manual - (Continued)

P-14 EJ HV-8811B CTMT Recirc Sump to A

N.A.

RHR Pump B Suction P-21 EJ HV-8840 RHR Hot Leg Recirc A

N.A.

Iso Valve P-87 EM HV-8802A*

SI Pump A Disch Hot A

N.A.

Leg Iso Valve I

P-48 EM HV-88028*

SI Pump B Disch Hot A

N.A.

Leg Iso Valve P-49 EM HV-8835 51 Pumps Disch to A

N.A.

Cold Leg Iso Valve P-89 EN HV-6 CTMT Spray Pump A A

N.A.

Discharge Iso Valve P-66 EN HV-12 CTMT Spray Pump B A

N.A.

Discharge Iso Valve 7.

Active for SIS P-80 BG HV-8105 CVCS Charging Line C

10 P-88 EH HV-8801A Boron Injection to A

N.A.

RCS Cold Legs P-88 EM HV-8801B Boron Injection to A

N.A.

RCS Cold Legs 8.

Hand-0perated and Check Valves P-41 BB V-118 RCP A Seal C

N.A.

Water Supply P-22 BB V-148 RCP B Seal C

N.A.

Water Supply P-39 BB V-178 RCP C Seal C

N.A.

Water Supply P-40 BB V-208 RCP D Seal C

N.A.

Water Supply "These valves were assumed to be closed during the accident analysis and are normally closed but may be opened on an intermittent basis under administrative control.

WOLF CREEK - UNIT 1 3/4 6-26