ML20072F733
| ML20072F733 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 02/28/1983 |
| From: | Belmore C, Hillman R BATTELLE NEW ENGLAND MARINE RESEARCH LABORATORY |
| To: | |
| Shared Package | |
| ML20072F728 | List: |
| References | |
| 15173, NUDOCS 8303240405 | |
| Download: ML20072F733 (21) | |
Text
_..
as PROGRESS REPORT e
FOR THE THIRTY-FIRST QUARTER on STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK GENERATING STATION to GPU NUCLEAR CORPORATION February 23,1983 by R.E. Hillman and C.I. Belmore REPORT NO.15173 November 21,1982 to January 20,1933 BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts G2332 8303240405 030315 PDR ADOCK 05000219 R
TABLE OF CONTENTS Page EX EC U TIV E SU M M ARY.................................................
1 IN TRO D U CTIO N......................................................
2 PROCEDUR ES AND INTERIM D ATA......................................
3 Ex p o s u r e Pane l s...................................................
3 W a t e r Q ua li t y.....................................................
3 Teredinid Gonadal Development Studies..............................
3 LIST OF TABLES Table 1.
Geographical Locations of Exposure Panel Arrays in Barnegat Bay, New Jersey.....................................
5 Table 2.
Incidence of Teredinidae in Panels Removed December 6-7,1982....
9 Table 3.
Incidence of Teredinidae in Panels Removed January 3-4,1983......
10 Table 4.
Incidence of Limnoria in Panels Removed December,1982 an d 3 an ua r y, 19 8 3............................................
11 Table 5.
Water Quality at Exposure Panel Stations, December 6-7, 1982......
12 Table 6.
Water Quality at Exposure Panel Stations, January 3-4,1983.......
13 Table 7.
Condition of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from November through D e ce m be r, 19 8 2..............................................
14 LIST OF FIGURES Figure 1.
Outline of Barnegat Bay Showing Geographical Locations of Exposure Panels 4
1 Executive Summary This progress report presents data from field and laboratory work during the period November 21,1982 to January 20,1983.
All field work during this quarter was carried out by GPU personnel.
Temperature, salinity, dissolved oxygen and pH were measured and recorded at each of the 20 stations during the two periods of exposure panel exchange except in December,1982 when there was an equipment malfunction at some of the stations (see Table 5).
The laboratory analysis of the exposure panels shows the species Teredo bartschi to be absent from any of the exposure panels in Barnegat Bay, New Jersey during the 1982 settling season.
Teredinidae were breeding and settling during the month of November this year at Station 1, which is a month later in the year than usual at this location.
Limnoria were present at Station 1 through 4A as in previous years. Juveniles were observed in panels removed from two stations in December,1982 and from three stations in January,1933. Last year juveniles were only recorded from one station in December and none in January.
The gonads of most specimens were found to be in the partially spawned to spent stage during November and December, which is typical for this time of year.
2 PROGRESS REPORT FOR THE THIRTY-FIRST QUARTER on STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK GENERATING STATION to GPU NUCLEAR CORPORATION FEBRUARY 28,1933 by Robert E. Hillman and C.I. Belmore REPORT NO.15173 November 21,1982 to January 20,1983 from BATTELLE New England Marine Research Laboratory Duxbury, Massachur.etts 02332 INTRODUCTION Battelle's New England Marine Research Laboratory is conducting an investigation to determine whether the generating station is affecting the resident marine borer population in Oyster Creek to the extent that that population is contributing significantly to marine borcr-caused damage in Barnegat Bay.
A description of the progam and procedures used may be found in the sixth annual report titled, " Study of Woodt:rer Populations in Relation to the Oyster Creek Generating Station," dated March 15,1932.
This report presents data for the thirty-first quarterly period from November 21,19S2 to January 20,1983.
3 PROCEDURES AND INTERIM DATA Exposure Panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods December 6-7,1982 and January 3-4, 1983. Long-term and short-term panels at all stations were retrieved and replaced by personnel from GPU's Oyster Creek Nuclear Generating Station.
Table i describes the geographical locations of the exposure sites. The data for the laboratory examination of the panels are presented in Tables 2 through 4.
Water Quality Salinity, water temperature, dissolved oxygen and pH were taken at each site by the GPU field team. The results for December,1932 and January,1933 are presented in Tables 5 and 6.
Teredinid Gonadal Development Studies Table 7 shows the gonad condition of the teredinid borers collected in November and December,1982. Included are results from panels exposed for periods ranging from 6 to 12 months.
4 3, %....
~ ~ -
N
_"_i..s.. P
\\ ~. ~.f
\\ \\,
[
s.
c W r' tir:) f
[W
/
A J
c\\
^
~
%.> ^ o
(..s, N
.s.'.'
k,(s r.
- y' a
C,->
\\'
fl
/
\\
.~
s
.\\x \\
\\
g 4.
b'
\\
os \\
n \\
. (}-
N ATLli. TIC y'
g, /,
- n. j \\
s
\\
y'.~~
e
~3, nr /c; q-s 4
9
\\ '.
i.v i ri.:s *d
\\
a
\\
')T.
'\\
.._ ~.2
'~
c.C../
L,
\\
'Q.3 /
\\
(\\
,.......... - 11:
.... f+/
';ECGC L
1 3 '.>
is tc.;:2
.i n.
'C'
,, s
\\-
.m ac-c :*
y
\\3 -w r.LOYSTER e
- ,s,,_
s.
s v-C_.u.z...
N c
q.e;!]
..C*'.'>.<r.....c,....... < -.... 10.. a a
BAR:;ECAT
'.iARETC'.N } /
v
[
!!AiCEGAT BEACII ~)
L-CITY 2
3 '.m r
C PA.'.EL 15?.AY
@,(
CC!;KLI::
h IS L/d;D b
d I
P 3.
' M:.
/
1t 7, ' =
ll
'6 ?;
- 1 L.,
to = - ce n 0,,. o *
, o.: 2.,i n
f Nf FIGURE 1.
OUTLIrlE OF BARilEGAT BAY SHOWIllG GEOGRAPHICAL LOCATI0tl 0F EXPOSURE PAtlELS
I TABLE
- 1. GEOGRAPll! CAL LOCATIONS OF BATTELLE NEW ENGLAND I,1ARINE RESEARCII LABORATORY'S EXi'OSURE PANEL ARRAYS IN BARNEGAT 15AY, NEW JERSEY Structure to be used for Nearest Previous Approxirnate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 1.
B.trnegat Coast Guard Finger Pier WC1 Lat. 39o 45.S'N Station, Barnegat inlet Bull: head WFCL 1948-1967 Long. 740 06.5'W 2.
Ash ton.\\larina Bulkhead WC 13,14 Lat. 390 40'N 1450 Bay Ave.
Long.740IFW Alanahawkin 3.
Iggie's Alarina Bulkhead WC 16,17, IS,19 Lat. 390 45'N East Bay Ave.
Lonog. 740 12.5'W Barnegat (Conklin Island) m l
4.
Liberty liarbor ilarina Bulkhead T C 21 Lat. 390 t 7'N l
i Washington Ave.
R. Turner Long. 74r' I t'W War etown Rutgers U.
l 4-A*.
Holiday liarbor ilarina Bulkhaad T C 21 Lat. 390 4S'N Lig'ithouse lirive R. Turner Long. 740 ll'N Waretown Rutgers U.
l 5.
Alouth of Oyster Creek, Dock WC 29,30 Lat. 39o 43.5'N l
Lot 4, Coomass Road Rutgers U.
Long 74010.3'W Of fshore Enc 6.
Oyster Creek //l Doch Lat. 390 4 3.S'N Lagoon, in shore End Long. 74010.3 5'W 37 Capstan Drive
TABLE
- 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude.
Site No.
Site Suspension of Rack Data Stations and Longitude 7.
Private Dock End of Dock WC 27,23 Lat. 390 43.5'N Dock Ave.
R. Turner Long. 740 ll.I'W Oyster Creek Rutgers U.
Sands Pt. Harbor Waretown 8.
Oyster Creek-R.R.
Cross Mernber WC 26 Lat. 390 43.7'N Bridge Bridge Rutgers U.
Long. 74012'W Discharge Canal 9.
Forked River Cross Member WC 31 Lat. 390 49.2'N cn South Branch R.R. Bridge intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 390 50.I'N Bay Ave.
Long. 740 ll.6'W Forked River 10A*.
Private Dock Under Dock Lat. 390 49'N 1217 Aquarius Ct.
Long. 74010'W Forked River 10B*.
Private Dock Under Dock Lat. 390 49.4'N 1307 Beach Blvd.
Long. 740 10.I'7/
Forked River 11.
Forked River Bulkhead -
Wc 35 Lat. 390 49.7'N (near mouth)
Rutgers U.
Long. 74010'W 1413 River View Drive
l TABLE
- 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude.
Site No.
Site Suspension of Racl:
Data Stations and Longitude 12.
Stouts Creek Bulkhead WC 3S,40,41 Lat. 390 50.5'N 1273 Capstan Drive R. Turner Long. 740 OS.S'W Wurtz Rutgers U.
13.
Rocknak's Yacht Basin End of Pier WC 46 Lat. 390 52'N Scaview Ave.
Long. 740 09'W Lanoka liarbor Cedar Creek 14.
Dicks Landing Pier WC 49 Lat. 390 54'W y
Island Drive R. Turner Long. 740 OS.I'W Bayville (Holly Park)
Nelson 15.
Winter Yacht Basin Inc.
Pier WC 57 Lat. 400 02.5'N Rt. 528 Long. 740 04.9'W Mantoloking Bridge 16.
Berkely Yacht Basin Pier WC 60,61 Lat. 390 55.9'N J. Street Long. 740 04.9'W Seaside 16A*.
Municipal Dock Pier WC 60,61 Lat. 390 56.6'N Seaside licights Long. 740 64.9'W 16B *.
Bayside Boats Pier WC 60,61 Lat. 390 56.6'N l
State liighway //35 and Long. 740 04.9'W Bay Boulevard Seaside IIcights, NJ
TABLE
- 1. (Continued)
I Structure to be used for Nearest Previous Approximate Latitude, Site No.
Site Suspension of Rack Data Stations and Longitude 17 Island Beach Pier WC68 Lat. 390 47.I'N State Park Long. 740 0.3.9'W (Sedge Island)
All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Rachs hung with nylon line from existing structures so the bottoin panels are close to, but not touching the bottom. Racks at Forked River railroad bridge and Oyster Creek railroad bridge suspended with wire rope.
l l
WC = Woodward-Clyde
)
I WFCL = William F. Clapp Laboratories Site 4-A installed April,1977.
Sites 10A,10B installed April,1978.
I Site 16 discontinued November,1981.
l Site 16A installed December,1981 - discontinued June,1982.
l Site 168 installed June,1932.
l l
i l
l l
l l
i e
9 TABLE 2. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED DECEMBER 6-7,1982 No.of Percent Size Range Station Panel Specimens Filled in mm Species Identification Remarks 1
P 650 99
<!-70 150 T. navalis, 75% of 500 Teredinidae*
specimens dead C
90
<1
<1 90 Teredinidac*
5 P
1 2
125 1 T. navalis C
0 7
P 6
9 14-200 5 T. navalis,1 4 live,2 dead Teredinidae
- C 0
9 P
3 10 170-200 1 B. gouldi,2 T. navalis C
0 10A P
4 14 85-290 2 B. gouldi,2 T. navalis C
0 10B P
1 4
250 1 B. gouldi C
0 11 P
77 90 30-205 2 B. gouldi,60 15 specimens T. navalis,15 dead Teredinidae
- C 0
13 P
3 13 210-235 3 B. gouldi C
0 15 P
2
<1 10-48 2 T. navalis I specimen dead C
0 16B P
1 3
190 1 B. gouldi C
0 17 P
9 10 9-130 6 T. navalis C
0 Stations 2-4 A, 6, S,10,12, and 14 - No Teredinidae present P = Long-term panel submerged June 1-2, 1982.
C = Short-term panel submerged November 1-2, 1982.
- = Not speciated due to size or condition.
10 TABLE 3. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED 3ANUARY 3-4,1983 No. of Percent Size Range Station Panel Specimens Filled in mm Species Identification Remarks 1
P 700 99 4-60 100 T. navalis 85% of 600 Teredinidae*
specimens dead C
0 3
P 2
5 145-200 2 B. gouldi C
0 7
P 4
2
<l-155 1 T. navalis,3 Teredinidae
- C 0
10 P
1 4
240 1 T. navalis C
0 10A P
2 5
140-160 2 T. navalis C
0 10B P
2 3
210-215 2 B. gouldi Idead C
0 11 P
62 95 25-190 1 B. gouldi, 57 4 Teredinidae T. navalis, dead 4 Teredinidae
- C 0
12 P
1 2
155 1 B. gouldi C
0 13 P
1 2
150 1 B. gouldi C
0 15 P
7 15 40-190 4 B. gog,2 1 T. navalis and T. na talis, 1 Teredinidae dead 1 Teredinidac*
C 0
17 P
20 20 2-120 19 T. navalis, 1 Teredinidae
- C 0
Stations 2, 4-6,3,9,14 and 16B - No Teredinidae present.
P = Long-term panel submerged July 6-7, 1932.
C = Short-term panel submerged December 6-7, 1982.
- = Not speciated due to size or condition.
11 TABLE 4. INCIDENCE OF LIMNORIA IN PANELS REMOVED DECEMBER,1932, AND JANUARY,1933 December January No. of No. of No.of No. of Station Panel Tunnels Specimens Tunnels Specimens 1
P 4
0 7
0 C
0 0
0 0
2 P
360 390*
345 300*
C 0
0 3
P 1
1 0
C 0
0 4
P 425 390 132 110*
C 0
0 4A P
6800 5000*
500 450*
C 1
1 0
Stations 5 through 17, no Limnoria present P = Long-term panel, submerged 6 months.
C = Short-term panel, submerged 1 month.
- = Juveniles present.
12 TABLE 5. WATER QUALITY AT EXPOSURE PANEL STATIONS DECEMBER,1932 1
Depth in Salinity Temperature 0**
Station Date Time Feet o/oo (oC)
(
1) pH*
1 12/6/32 0950 3.0 23.5 13.8 8.0 8.0 2
12/6/82 1045 2.5 20.4 14.1 7.5 7.9 3
12/6/32 1125 0.5 20.6 14.8 S.2 8.2 4
12/6/82 1150 2.5 21.9 14.6 8.9 4A 12/6/82 1220 0.5 19.8 14.2 8.9 5
12/6/32 1340 0.8 20.5 16.8 S.5 6
12/6/32 1355 1.0 20.5 16.6 S.5 7
12/6/32 1410 0.8 20.5 17.5 8.1 S
12/6/32 1430 3.0 20.7 18.0 8.2 9
12/6/32 1505 3.0 20.9 15.7 9.5 10 12/7/82 1430 2.5 19.3 13.3 9.9 10A 12/6/32 1530 0.8 21.0 15.4 9.3 10B 12/6/S2 1550 2.0 21.0 16.0 11 12/6/32 1605 0.3 22.3 14.5 12 12/7/32 1350 1.0 16.7 12.0 9.5 13 12/7/32 1330 1.2 15.0 12.2 9.2 14 12/7/82 1300 1.5 15.2 12.9 9.1 15 12/7/32 0940 1.0 16.8 12.1 8.9 16B 12/7/32 1030 2.0 14.6 11.9 9.5 17 12/7/82 1120 0.2 22.2 11.8 10.4 No reading taken.
pH meter not working properly af ter Station 3.
DO readings questionable, meter erratic at Stations 4 through 7.
YSI DO meter temperature reading incorrect at Stations 8,9 and 10A, therefore DO reading may be invalid at these stations.
13 i
TABLE 6. WATER QUALITY AT EXPOSURE PANEL STATIONS JANUARY,1983 Depth in Salinity Temperature 02 Station Date Time Feet o/oo (oC)
(mg/1) pH I
1/3/33 1020 3.5 23.5 4.9 12.6 8.3 2
1/3/83 1110 0.7 23.4 3.9 12.6 8.2 3
1/3/83 1150 1.0 25.9 4.2 12.0 8.3 4
1/3/33 1215 1.0 26.1 4.5 12.1 8.3 4A 1/3/33 1230 1.0 26.7 4.7 11.6 8.3 5
1/3/S3 1400 0.7 23.9 6.7 10.4 8.2 6
1/3/83 1415 1.0 23.1 5.9 10.7 8.1 7
1/3/32 1435 0.7 23.3 6.7 11.1 8.2 3
1/3/83 1505 3.5 22.7 6.4 11.6 8.3 9
1/3/33 1540 3.0 23.8 4.6 11.7 8.3 10 1/4/33 1412 2.5 21.5 5.5 11.2 8.1 10A 1/3/83 1608 1.0 24.0 4.6 11.9 8.2 10B 1/3/S3 1622 2.5 24.4 4.5 12.0 S.3 11 1/4/33 1440 0.3 24.1 3.1 11.8 8.3 12 1/4/33 1303 1.5 23.7 4.3 11.7 8.2 13 1/4/33 1235 1.5 21.0 3.9 12.1 8.2 14 1/4/33 1203 2.0 22.1 3.3 12.4 8.3 15 1/4/33 1040 2.0 22.8 3.1 13.2 8.2 16B 1/4/S3 1110 2.5 18.6 2.0 13.1 8.1 17 1/4/33 1145 0.5 27.1 1.6 13.9 8.2
TABLE 7. CONDITION OF GONADS OF TEREDINID BORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM NOVEMBER AND DECEMBER,1982 EA = Early active; LA = Late active; R = Ripe; PS = Partially spawneil; S = Spent; M = Male; F = Female; 11 = liermaphrodite Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments ll60a 14 Nov S2 6
Bant:ia gouldi M
S b
Bankia gouldi M
S 1161a 10A Nov S2 6
Teredo navalis F
S b
Teredo navalis M
S l
c Teredo navalis F
PS d
Teredo navalis M
S l
1162a 15 Nov S2 6
Teredo navalis H
PS I
b Teredo navalis H
EA c
Teredo navalis M
S A
d Teredo navalis No discernable gonad 1163 15 Nov S2 6
Bankia gouldi No discernable gonad ll64a 11 Nov 32 6
Teredo navalis M
PS b
Teredo navalis H
S c
Teredo navalis il PS d
Teredo navalis F
PS I
e Teredo navalis At 5
f Teredo navalis H
S g
Teredo navalis M
PS h
Teredo navalis F
S 1
i Teredo navalis M
S l
j' Teredo navalis F
S i
k Teredo navalis M
S 1
Teredo navalis M
S m
Teredo navalis M
S l
Tabl2 7. (continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments I
n Teredo navalis M
S o
Teredo navalis H
S p
Teredo navalis M
S q
Teredo navalis M
S l
Il65a 13 Nov S2 6
Bankia gouldi M
S b
Bankia gouldi M
S c
Bankia gouldi M
S d
Bankia gouldi No discernable gonad e
Bankia gouldi M
S 1166 8
Nov 32 6
Teredo navalis F
R Dead when fixed 1167a 16B Nov 82 5
Bankia gouldi M
S b
Bankia gouldi M
S m
1168 5
Nov 82 6
Teredo navalis F
S 1169a 17 Nov 82 6
Terdeo navalis No discernable gonad b
Teredo navalis H
S c
Teredo navalis
.M S
d Teredo navalis M
S e
Teredo navalis M
LA 1170 9
Nov 82 6
Teredo navalis H
S tl71a 17 Nov 82 12 Teredo navalis M
S Special panel b
Teredo navalis M
S c'
Teredo navalis No discernable gonad d
Teredo navalis No discernable gonad e
Teredo navalis 11 S
f Teredo navalis H
S g
Teredo navalis F
S h
Teredo navalis H
S i
Teredo navalis F
S I
Tabla 7. (continued)
Month No. Months Gonad Specimen No.
Station Reinoved Exposed Species Sex Condition Comments ll72a 12 Nov S2 12 Bankia gouldi Special panel; no discernable gonad b
Bankia gouldi M
S 1173a 11 Nov 82 12 Teredo navalis M
S Special panel b
Teredo navalis F
S c
Teredo navalis F
S 1174a 11 Nov 32 12 Bankia gouldi M
S Special panel b
Bankia gouldi M
S c
Bankia gouldi No discernable gon.J l
d Bankia gouldi No discernable gonad I
5 1175 16B Dec S2 6
Bankia gouldi No discernable gonad 1176a 13 Dec 82 6
Bankia gouldi No discernable gonad b
Bankia gouldi No discernable gonad l
c Bankia gouldi No discernable gonad l
1177 10B Dec 32 6
Bankia gouldi M
S l
Il78a 10A Dec 82 6
Teredo navalis F
S b
Teredo navalis F
S 1179 5
Dec 32 6
Teredo navalis F
S tl80a 10A Dec S2 6
Bankia gouldi M
S b
Bankia gouldi M
S Il81a 7
Dec 32 6
Teredo navalis F
S b
Teredo navalis F
S c
Teredo navalis F
S d
Teredo navalis No discernable gonad l
l 1
I Table 7. (continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1182 15 Dec S2 15 Teredo navalis M
S 1183a 9
Dec S2 6
Teredo navalis 11 S
b Teredo navalis F
S 1
1184 9
Dec S2 6
Bankia gouldi M
S IIS5a 11 Dec S2 6
Banhia gouldi No discernable gonad b
Banhia gouldi M
S 1IS6a 11 Dec S2 6
Teredo navalis M
S b
Teredo navalis M
PS c
Teredo navalis M
S d
Teredo navalis F
PS e
Teredo navalis F
PS f
Teredo navalis M
PS g
Teredo navalis F
S h
Teredo navalis F
S i
Teredo navalis H
S j
Teredo navalis F
S k
Teredo navalis M
S 1
Teredo navalis M
PS 1137a 17 Dec S2 6
Teredo navalis H
S b
Teredo navalis F
S c
Teredo navalis 11 S
<j Teredo navalis M
S e
Teredo navalis 11 S
f Teredo navalis M
a
Table 7. (continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments Il38a 1
Dec S2 6
Teredo navalis F
PS s
b Teredo navalis 11 S
~
c Teredo navalis F
PS d
Teredo navalis M
PS e
Teredo navalis F
PS f
Teredo navalis F
S g
Teredo navalis M
S h
Teredo navalis F
PS i
Teredo navalis M
S j
Teredo navalis F
PS k
Teredo navatis H
S 1
Teredo navalis F
S m
Teredo navalis M
S n
Teredo navalis H
S o
Teredo navalis 11 PS E
1139 17 Dec 82 12 Teredo navalis H
S Special panel 1190 7
Dec S2 12 Bankia gouldi M
S Special panet 1191 12 Dec 32 12 Bankia gouldi.
M S'
Special panet i192a 11 Dec 32 12 Teredo navalis M
S Special panet b
Teredo navalis H
S c
Teledo navalis H
S d
l'eredo navalis.
F PS e
Teredo navalis F
S
,. =
=
m e
1 a
%9 Battelle New England Marine Research Laboratory 397 Washington Street Duxbury, Massachusetts 02332 Telephone (617) 934-5682 y-
-