| | | Reporting criterion |
|---|
| 05000373/LER-1983-001, Forwards LER 83-001/01T-0 | Forwards LER 83-001/01T-0 | |
| 05000373/LER-1983-001-01, /01T-0:on 830211,pressure Switch IE12-N413A in Reactor Vessel Pressure Lpcs/Lpci Valve Permissive Circuit, Found to Have Leaked Past Actuator Stem.Caused by Failure of Seal Inside Switches.Switches Replaced | /01T-0:on 830211,pressure Switch IE12-N413A in Reactor Vessel Pressure Lpcs/Lpci Valve Permissive Circuit, Found to Have Leaked Past Actuator Stem.Caused by Failure of Seal Inside Switches.Switches Replaced | |
| 05000373/LER-1983-002, Forwards LER 83-002/03L-0 | Forwards LER 83-002/03L-0 | |
| 05000373/LER-1983-002-03, /03L-0:on 830121,functional Testing of HPCS Keep Filled Pressure Alarm Not Performed Monthly from 820415 to 0922.Caused by Personnel Error.Tech Spec Review Will Be Completed by 830401 | /03L-0:on 830121,functional Testing of HPCS Keep Filled Pressure Alarm Not Performed Monthly from 820415 to 0922.Caused by Personnel Error.Tech Spec Review Will Be Completed by 830401 | |
| 05000373/LER-1983-003-03, /03L-0:on 830118,functional Testing of Condenser Low Vacuum MSIV Isolation Pressure Switches Not Performed for Aug 1982 & Calibr Not Performed for Third Quarter 1982. Caused by Personnel Error.Review of Tech Specs in Progres | /03L-0:on 830118,functional Testing of Condenser Low Vacuum MSIV Isolation Pressure Switches Not Performed for Aug 1982 & Calibr Not Performed for Third Quarter 1982. Caused by Personnel Error.Review of Tech Specs in Progress | |
| 05000373/LER-1983-003, Forwards LER 83-003/03L-0 | Forwards LER 83-003/03L-0 | |
| 05000373/LER-1983-004, Forwards LER 83-004/03L-0 | Forwards LER 83-004/03L-0 | |
| 05000373/LER-1983-004-03, /03L-0:on 830121,calibr of Hydrogen Recombiner Temp Instrumentation LIS-HG-01 Not Performed in Apr 1982. Caused by Surveillance Requirement Overlooked by Personnel. Requirements Reviewed | /03L-0:on 830121,calibr of Hydrogen Recombiner Temp Instrumentation LIS-HG-01 Not Performed in Apr 1982. Caused by Surveillance Requirement Overlooked by Personnel. Requirements Reviewed | |
| 05000373/LER-1983-005, Forwards LER 83-005/01T-0 | Forwards LER 83-005/01T-0 | |
| 05000373/LER-1983-006-03, /03L-0:on 830202,steam Observed Leaking from MSIV,1B21-F028A,due to Two Cracks 180 Degrees Apart in Weld Where 1MS20AA-2-inch Drain Line Attached to Valve Body. Caused by Improper Weld Application.Weld Repaired | /03L-0:on 830202,steam Observed Leaking from MSIV,1B21-F028A,due to Two Cracks 180 Degrees Apart in Weld Where 1MS20AA-2-inch Drain Line Attached to Valve Body. Caused by Improper Weld Application.Weld Repaired | |
| 05000373/LER-1983-006, Forwards Updated LER 83-006/01X-1 | Forwards Updated LER 83-006/01X-1 | |
| 05000373/LER-1983-006-01, Cracks Discovered in MSIV 1B21-F028A Drain Line Weld.Caused by Improper Weld Application.Weld Repaired.New Weld Ground Down to Eliminate Notches Between Passes & Magnetic Particle Tested | Cracks Discovered in MSIV 1B21-F028A Drain Line Weld.Caused by Improper Weld Application.Weld Repaired.New Weld Ground Down to Eliminate Notches Between Passes & Magnetic Particle Tested | |
| 05000373/LER-1983-007, Forwards LER 83-007/01T-0 | Forwards LER 83-007/01T-0 | |
| 05000373/LER-1983-007-01, /01T-0:on 830205,observed Steam Leaking from MSIV 1B21-FO22C Due to Crack in Weld Where 1MS14AC 2-inch Drainline Connects to Valve Body.Caused by Improper Weld Application.Weld Repaired & Ground to Eliminate Notches | /01T-0:on 830205,observed Steam Leaking from MSIV 1B21-FO22C Due to Crack in Weld Where 1MS14AC 2-inch Drainline Connects to Valve Body.Caused by Improper Weld Application.Weld Repaired & Ground to Eliminate Notches | |
| 05000373/LER-1983-008, Forwards LER 83-008/03L-0 | Forwards LER 83-008/03L-0 | |
| 05000373/LER-1983-008-03, /03L-0:on 830203,while Performing Visual Insp Per Tech Specs,Snubber LC01-1106S Found Inoperable.Caused by Missing Pin Due to Improper Field Practices.Pin Replaced | /03L-0:on 830203,while Performing Visual Insp Per Tech Specs,Snubber LC01-1106S Found Inoperable.Caused by Missing Pin Due to Improper Field Practices.Pin Replaced | |
| 05000373/LER-1983-010, Forwards LER 83-010/03L-0 | Forwards LER 83-010/03L-0 | |
| 05000373/LER-1983-010-03, /03L-0:on 830209,during Insp of Main Steam Drain Line Piping,Mechanical Restraint MS20-1012X Found Installed on Line 1MS20BA-1-1/2 Inch in Violation of Plant Design. Caused by Personnel Oversight.Restraint Removed | /03L-0:on 830209,during Insp of Main Steam Drain Line Piping,Mechanical Restraint MS20-1012X Found Installed on Line 1MS20BA-1-1/2 Inch in Violation of Plant Design. Caused by Personnel Oversight.Restraint Removed | |
| 05000373/LER-1983-011, Forwards LER 83-011/03L-0 | Forwards LER 83-011/03L-0 | |
| 05000373/LER-1983-011-03, /03L-0:on 830208,during LIS-NB-01,LIS 1B21-NO24B Setpoint Found Out of Tolerance in Nonconservative Direction.Cause Undetermined.Switch Recalibr.Itt Barton Model 288A Trended to Assist in Determining Further Action | /03L-0:on 830208,during LIS-NB-01,LIS 1B21-NO24B Setpoint Found Out of Tolerance in Nonconservative Direction.Cause Undetermined.Switch Recalibr.Itt Barton Model 288A Trended to Assist in Determining Further Action | |
| 05000373/LER-1983-012-03, /03L-0:on 830210,during LIS-R1-03,RCIC Leak Detection Temp Switch Setpoints Found Out of Calibr.Caused by Defective Calibr Instrument.Temp Switches Recalibr.Calibr Instrument Replaced | /03L-0:on 830210,during LIS-R1-03,RCIC Leak Detection Temp Switch Setpoints Found Out of Calibr.Caused by Defective Calibr Instrument.Temp Switches Recalibr.Calibr Instrument Replaced | |
| 05000373/LER-1983-012, Forwards LER 83-012/03L-0 | Forwards LER 83-012/03L-0 | |
| 05000373/LER-1983-013, Forwards LER 83-013/03L-0 | Forwards LER 83-013/03L-0 | |
| 05000373/LER-1983-014-03, /03L-0:on 830215,differential Pressure Indicating Switch 1E31-N013A High Differential Pressure Setpoint Found Out of Tolerance in Nonconservative Direction.Cause Undetermined.Switch Recalibr | /03L-0:on 830215,differential Pressure Indicating Switch 1E31-N013A High Differential Pressure Setpoint Found Out of Tolerance in Nonconservative Direction.Cause Undetermined.Switch Recalibr | |
| 05000373/LER-1983-014, Forwards LER 83-014/03L-0 | Forwards LER 83-014/03L-0 | |
| 05000373/LER-1983-015-03, /03L-0:on 830217,while Testing Diesel Generator 1B Per LOS-DG-M3,diesel Tripped While Being Off Loaded.Diesel Restarted & Speed Varied Between 400 & 900 Rpm.Caused by Bad Connection at Run Solenoid.Connection Reconnected | /03L-0:on 830217,while Testing Diesel Generator 1B Per LOS-DG-M3,diesel Tripped While Being Off Loaded.Diesel Restarted & Speed Varied Between 400 & 900 Rpm.Caused by Bad Connection at Run Solenoid.Connection Reconnected | |
| 05000373/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl | Forwards LER 83-015/03L-0.Detailed Event Analysis Encl | |
| 05000373/LER-1983-016, Forwards LER 83-016/03L-0 | Forwards LER 83-016/03L-0 | |
| 05000373/LER-1983-016-03, /03L-0:on 830308,during Functional test,LIS-CO-02, Electrothermal Links Inadvertently Fired in 0 & 1B Diesel Generator Rooms.Caused by Improper Performance of Procedure. Dampers Opened.Electrothermal Links Replaced | /03L-0:on 830308,during Functional test,LIS-CO-02, Electrothermal Links Inadvertently Fired in 0 & 1B Diesel Generator Rooms.Caused by Improper Performance of Procedure. Dampers Opened.Electrothermal Links Replaced | |
| 05000373/LER-1983-017, Forwards LER 83-017/03L-0 | Forwards LER 83-017/03L-0 | |
| 05000373/LER-1983-017-03, /03L-0:on 830222,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Flow Instrument Probe Being Airbound Thus Preventing Transmittal of Correct Signal. Probe vented.LIS-WL-01 Performed Satisfactorily | /03L-0:on 830222,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Flow Instrument Probe Being Airbound Thus Preventing Transmittal of Correct Signal. Probe vented.LIS-WL-01 Performed Satisfactorily | |
| 05000373/LER-1983-018, Forwards LER 83-018/03L-0 | Forwards LER 83-018/03L-0 | |
| 05000373/LER-1983-019, Forwards LER 83-019/03L-0 | Forwards LER 83-019/03L-0 | |
| 05000373/LER-1983-019-03, /03L-0:on 830302,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Instrument Probe Being Either Airbound or Plugged.Operating Surveillance Revised to Restrict Valve Position | /03L-0:on 830302,lake Blowdown Flow Recorder Gave Incorrect Readings.Caused by Instrument Probe Being Either Airbound or Plugged.Operating Surveillance Revised to Restrict Valve Position | |
| 05000373/LER-1983-020-03, /03L-0:on 830305,pressure Switches 1E31-N022A,B,C & D Setpoints Found Out of Tolerance.Cause of Setpoint Drift Undetermined.Switches Recalibr & Returned to Svc | /03L-0:on 830305,pressure Switches 1E31-N022A,B,C & D Setpoints Found Out of Tolerance.Cause of Setpoint Drift Undetermined.Switches Recalibr & Returned to Svc | |
| 05000373/LER-1983-020, Forwards LER 83-020/03L-0 | Forwards LER 83-020/03L-0 | |
| 05000373/LER-1983-021, Forwards LER 83-021/01T-0 | Forwards LER 83-021/01T-0 | |
| 05000373/LER-1983-021-01, /01T-0:on 830323,during IEEE-323 Environ Qualification Testing,Circuit Breakers CB-13,11 & 9 Found to Have Thermal Overload Trip & Reset Problems in Simulated post-LOCA Environ.Caused by Incorrect Breaker Selection | /01T-0:on 830323,during IEEE-323 Environ Qualification Testing,Circuit Breakers CB-13,11 & 9 Found to Have Thermal Overload Trip & Reset Problems in Simulated post-LOCA Environ.Caused by Incorrect Breaker Selection | |
| 05000373/LER-1983-022-03, /03L-0:on 830317,following Scram,Reactor Recirculation Pump Suction Temp Dropped in Excess of 100 F in 1 H.Caused by Delay in Recognizing That Water Input Was from Condensate Booster Pump.Procedure Written | /03L-0:on 830317,following Scram,Reactor Recirculation Pump Suction Temp Dropped in Excess of 100 F in 1 H.Caused by Delay in Recognizing That Water Input Was from Condensate Booster Pump.Procedure Written | |
| 05000373/LER-1983-022, Forwards LER 83-022/03L-0 | Forwards LER 83-022/03L-0 | |
| 05000373/LER-1983-023, Forwards LER 83-023/03L-0 | Forwards LER 83-023/03L-0 | |
| 05000373/LER-1983-023-03, /03L-0:on 830310,calibr Indicating Switches 1B21-N100A & B Found Out of Tolerance in Nonconservative Direction.Caused by Instrument Drift.Adjustment of Setpoint Considered | /03L-0:on 830310,calibr Indicating Switches 1B21-N100A & B Found Out of Tolerance in Nonconservative Direction.Caused by Instrument Drift.Adjustment of Setpoint Considered | |
| 05000373/LER-1983-024, Forwards LER 83-024/03L-0 | Forwards LER 83-024/03L-0 | |
| 05000373/LER-1983-024-03, /03L-0:on 830312,control Rod Drive at Core Location 18-15 Indicated Overtravel When Withdrawn to Full Out Position for Startup.Caused by Inner Filter Retainer Spring Damage Due to Excessive Crud Buildup.Drive Recoupled | /03L-0:on 830312,control Rod Drive at Core Location 18-15 Indicated Overtravel When Withdrawn to Full Out Position for Startup.Caused by Inner Filter Retainer Spring Damage Due to Excessive Crud Buildup.Drive Recoupled | |
| 05000373/LER-1983-025, Forwards LER 83-025/03L-0 | Forwards LER 83-025/03L-0 | |
| 05000373/LER-1983-025-03, /03L-0:on 830315,offgas Hydrogen Analyzer 1B Found Operating Incorrectly While Analyzer 1A Inoperable. Caused by Defective Timer & Defective Hydrogen Sensor, Respectively.Timer & Sensor Repaired | /03L-0:on 830315,offgas Hydrogen Analyzer 1B Found Operating Incorrectly While Analyzer 1A Inoperable. Caused by Defective Timer & Defective Hydrogen Sensor, Respectively.Timer & Sensor Repaired | |
| 05000373/LER-1983-026, Forwards LER 83-026/03L-0 | Forwards LER 83-026/03L-0 | |
| 05000373/LER-1983-027-63, /03L-0:on 830320,steam Leak on Main Turbine Control Valve 1 Stem Seal Leakoff Line ITD20AA 1-/2 Inches Discovered.Caused by Overlap of Weldments.Welds Repaired | /03L-0:on 830320,steam Leak on Main Turbine Control Valve 1 Stem Seal Leakoff Line ITD20AA 1-/2 Inches Discovered.Caused by Overlap of Weldments.Welds Repaired | |
| 05000373/LER-1983-027, Forwards LER 83-027/03L-0 | Forwards LER 83-027/03L-0 | |
| 05000373/LER-1983-028-03, /03L-0:on 830320,steam Leak Discovered on Offgas Steam Jet Air Ejector 1A Drain Line to Turbine Bldg Equipment Drains.Caused by Defective Weldment.Work Request L23380 Generated to Repair Weldment | /03L-0:on 830320,steam Leak Discovered on Offgas Steam Jet Air Ejector 1A Drain Line to Turbine Bldg Equipment Drains.Caused by Defective Weldment.Work Request L23380 Generated to Repair Weldment | |