- 05000348/LER-1983-021-03, /03L-0:on 830506,power Supply Breaker HBL7R Opened.Possibly Caused by Personnel Inadvertently Tripping Breaker by Closing Locker.Locker Moved + (ML20072A851)
- ML20072A860 + (ML20072A860)
- ML20072A862 + (ML20072A862)
- ML20072A867 + (ML20072A867)
- ML20072A870 + (ML20072A870)
- ML20072A871 + (ML20072A871)
- ML20072A876 + (ML20072A876)
- ML20072A878 + (ML20072A878)
- ML20072A883 + (ML20072A883)
- ML20072A885 + (ML20072A885)
- 0CAN048326, Advises That Addl Time Required to Review Annual Environ Operating Rept.Rept Will Be Submitted by 830531 + (ML20072A891)
- ML20072A896 + (ML20072A896)
- ML20072A898 + (ML20072A898)
- ML20072A905 + (ML20072A905)
- 05000255/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20072A912)
- ML20072A915 + (ML20072A915)
- ML20072A916 + (ML20072A916)
- 05000255/LER-1982-049-03, /03L-0:on 821220,during Routine Shift Surveillance,Fire Sys Alarm Panel C-47 Found Inoperable Due to Loss of Power.Caused by Damaged Wires in Remote Flow Switch Resulting in Short Circuit.Wires & Contacts Repaired + (ML20072A917)
- ML20072A921 + (ML20072A921)
- ML20072A923 + (ML20072A923)
- ML20072A929 + (ML20072A929)
- ML20072A933 + (ML20072A933)
- ML20072A934 + (ML20072A934)
- ML20072A936 + (ML20072A936)
- BECO-LTR-94-085, Forwards fitness-for- Duty Program Performance Data for Period Jan-June 1994 + (ML20072A940)
- 05000296/LER-1983-030-03, /03L-0:on 830504,hydrogen Analyzer B Removed from Svc to Replace Defective Hydrogen Sample Inlet Pump Motor. Caused by Worn End Bell.Pump & Motor Assembly Replaced & SI 4.7.H Successfully Completed + (ML20072A942)
- TXX-3659, Forwards Final Response to NUREG-0612, Control of Heavy Loads at Nuclear Power Plants + (ML20072A945)
- 1CAN018305, Requests Extension Until 830318 to Request Hearing on NRC 821210 Order Requiring Installation of Inadequate Core Cooling Instrumentation Sys.Technical Evaluation Underway to Ensure Requirements Can Be Fulfilled + (ML20072A946)
- ML20072A955 + (ML20072A955)
- B10650, Interim Deficiency Rept Re Pipe Strap Design Specified for Installation W/O Qualification.Initially Reported on 821122. Evaluation to Determine Pipe Straps for Which Design Loads Exceed Allowable Limits Continuing + (ML20072A957)
- TXX-3683, Forwards Audit Rept Re Environ Qualification Verification of Installed Equipment Per Request.No Model Identification Indicated on Recombiner,However,Ratings Info on Nameplate Sufficient to Establish Model Identify + (ML20072A958)
- 05000321/LER-1994-008, :on 940714,output Breakers for B RPS Motor Generator Set Opened.Caused by Component Failure.Relay Was Replaced Per Maintenance Work Order 1-94-3570 & MG Set Was Returned to Service + (ML20072A961)
- ML20072A967 + (ML20072A967)
- ML20072A968 + (ML20072A968)
- ML20072A969 + (ML20072A969)
- ML20072A974 + (ML20072A974)
- ML20072A978 + (ML20072A978)
- 0CAN058316, Updates Status of Efforts & Progress Re Drawing Control. Progress Made in Program to Update Mylars Transferred from Corporate Ofc.As of 830511,2,714 Drawings Updated & Reissued.Info Responds to IE Bulletin 80-06 + (ML20072A984)
- ML20072A986 + (ML20072A986)
- ML20072A991 + (ML20072A991)
- ML20072A993 + (ML20072A993)
- ML20072B000 + (ML20072B000)
- ML20072B002 + (ML20072B002)
- ML20072B005 + (ML20072B005)
- 05000328/LER-1983-069-03, /03L-0:on 830508,RCS Subcooling Margin Monitor Declared Inoperable Due to Loss of Plant Process Computer. Caused by Breaker Operation on Power Grid Sys.Computer Restarted & Monitor Returned to Svc + (ML20072B008)