- 05000260/LER-1982-007-03, /03L-0:on 820126,while Performing SI 4.2.A-3, Reactor low-water Level Switch Lis-3-56A Switch Number 2 Was Found 8% Out of Tolerance.Caused by Setpoint Drift.Yarway Model 4418c Switch Recalibr & Functionally Tested + (ML20071H573)
- PY-CEI-NRR-1828, Responds to NRC Re Violation Noted in Insp Rept 50-440/94-06.Corrective Actions:M&Te That Was Unattended Was Collected & Delivered to Lab & Training on M&TE Users Guide Was Developed + (ML20071H574)
- 05000328/LER-1983-064-03, /03L-0:on 830420,auxiliary Feedwater Automatic Valve 2-LCV-3-148 Failed to Close on Demand from Control Board.Caused by Failure of Beckman Model 8813-2098-0200 Controller Due to Faulty Voltage + (ML20071H575)
- ML20071H576 + (ML20071H576)
- ML20071H577 + (ML20071H577)
- ML20071H580 + (ML20071H580)
- ML20071H581 + (ML20071H581)
- ML20071H582 + (ML20071H582)
- 3F0794-01, Provides Brief Discussion of Outage Related Mods & Activities of Mutual Interest & Results of Outage Goals, Following Completion of Refuel 9 + (ML20071H584)
- 05000280/LER-1982-002-03, /03L-0:on 820120,both Containment Pumps Declared Inoperable by Failing to Develop Flow.Caused by Water Accumulation in Common Discharge Piping.Piping Drained & Pumps Returned to Svc + (ML20071H587)
- 05000369/LER-1983-019-03, /03L-0:on 830413,representative Fuel Pool Ventilation Sys Carbon Filter Sample Analysis Indicated Sample Failed to Meet Methyl Iodide Penetration Criteria. Sample Analyses Made to Determine Cause + (ML20071H588)
- NRC-94-0045, Responds to NRC Re Violations Noted in Insp Rept 50-341/94-07.Corrective Action:Individuals Involved Were Disciplined + (ML20071H589)
- AECM-83-0280, Final RO 83-002/1:on 830201,smoke Detectors on Elevation 119 Ft of Auxiliary Bldg Covered to Perform Planned Maint. Hourly Fire Watch Established.Detectors Restored to Svc on 830509 + (ML20071H590)
- 05000280/LER-1982-003-03, /03L-0:on 820122,loss of Boric Acid Flow to Blender Observed.Caused by Inadequate Insulation on FT-1113 & Adjacent Piping.Blockages Removed or Freed & Addl Insulation Added to Prevent Recurrence + (ML20071H591)
- ML20071H596 + (ML20071H596)
- ML20071H597 + (ML20071H597)
- ML20071H598 + (ML20071H598)
- ML20071H599 + (ML20071H599)
- 05000260/LER-1982-050, Forwards Updated LER 82-050/03X-1 + (ML20071H602)
- 05000352/LER-1994-009, :on 940617,HVAC Exhaust Plenum High Radiation Monitor Inadvertently Tripped.Caused by Malfunction of Alarm Circuit Card within Monitor.Failed Alarm Circuit Will Be Returned to Manufacturer for Further Analysis + (ML20071H603)
- ML20071H604 + (ML20071H604)
- ML20071H605 + (ML20071H605)
- 05000280/LER-1982-008-03, /03L-0:on 820121,instrument Malfunction Resulted in Loss of All Pressurized Heaters.Caused by Short in One Pressurized Level Comparator.Short Repaired & Pressurizer Control Sys Returned to Normal Condition + (ML20071H607)
- L-83-311, Clarifies 830418 Final Deficiency Rept Re Diesel Generator Start Relay Defect.Addl Indication Provided to Indicate to Control Room When Master Control Switch,Located in Diesel Generator Bldg,Is in Stop Position + (ML20071H609)
- ML20071H610 + (ML20071H610)
- 05000338/LER-1983-025-03, /03L-0:on 830429,while Conducting Surveillance Test,Conditioning Module TC-MM-100A to Meteorological 33-ft Temp Chart Recorder Drifted 1.6 F.Caused by Instrument Drift.Module Recalbr + (ML20071H611)
- 05000302/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20071H613)
- ML20071H614 + (ML20071H614)
- ML20071H618 + (ML20071H618)
- 05000302/LER-1982-006-03, /03L-0:on 820125,during Weekly Battery Check, SP-520,on Station Battery 3B,pilot Cell 115 Failed to Meet Acceptance Criteria.Caused by Dissipation of Charge Between Surveillances.Battery Recharged & Returned to Svc + (ML20071H619)
- ML20071H621 + (ML20071H621)
- 05000259/LER-1981-069, Forwards Updated LER 81-069/03X-1 + (ML20071H624)
- ML20071H625 + (ML20071H625)
- ML20071H626 + (ML20071H626)
- ML20071H628 + (ML20071H628)
- ML20071H631 + (ML20071H631)
- 05000302/LER-1982-007, Forwards LER 82-007/03L-0 + (ML20071H633)
- ML20071H636 + (ML20071H636)
- ML20071H637 + (ML20071H637)
- ML20071H639 + (ML20071H639)
- ML20071H641 + (ML20071H641)
- ML20071H642 + (ML20071H642)
- 05000280/LER-1981-081, /03L-0:on 820121,during Research for LER 81-081/03L-0,found That Original Vacuum Pumps Were Replaced W/Pumps That Failed to Meet Required Seismic Qualifications. Study of Present Pumps Completed.Assistance Request Issued + (ML20071H644)
- ST-HL-AE-4833, Responds to NRC Re Violations Noted in Insp Rept 50-498/94-18 & 50-499/94-18.Corrective Action:Increased Number of Personnel Per Shift + (ML20071H646)
- ML20071H647 + (ML20071H647)
- 05000328/LER-1983-059-03, /03L-0:on 830422,while in Mode 1,rod Position Indication for Rod C-5 in Shutdown Bank D Misaligned by 12 Steps & Declared Inoperable.Cause Unknown.Rod Position Indicator & Cable Verified + (ML20071H650)
- 05000259/LER-1981-069-03, During Performance of SI 4.8.B.4-4,gaseous Channel of Continuous Air Monitor O-RM-90-252 Read Downscale.Caused by Instrument Drift. Courting Ratemeter Calibr & Channel Returned to Svc + (ML20071H652)
- AECM-83-0287, RO 83-031/0:on 830415,fire Doors Blocked Open for 21 Days, Exceeding 7-day Time Limit.Doors Closed & Restored to Operation + (ML20071H653)
- ML20071H655 + (ML20071H655)
- ML20071H656 + (ML20071H656)
- 05000302/LER-1982-007-03, /03L-0:on 820123,starting Air Pressure for Emergency Diesel Generator B Too Low for Automatic Start & Air Pressure Low Alarm Did Not Actuate.Caused by EGV-16,air Tank Blowdown Valve Not Fully Closed & Alarm Malfunction + (ML20071H657)