- 05000346/LER-1983-017-03, /03L-0:on 830411,spent Fuel Pool (SFP) Level Verification Surveillance Test Ordered Later than Tech Spec Requirement.Caused by Personnel Error.Sfp Level Verified. Memo on Schedules Planned + (ML20071G445)
- ML20071G446 + (ML20071G446)
- 05000331/LER-1983-012-01, /01T-0:on 830425,full Scram Should Have Been Received When Mode Switch Moved from Refuel to Shutdown, However,Sys a Did Not Trip.Caused by Faulty Solder Connection on Rectifier.Connections Resoldered + (ML20071G449)
- ML20071G451 + (ML20071G451)
- ML20071G457 + (ML20071G457)
- 05000373/LER-1983-038-03, /03L-0:on 830207,during Performance of LIS-HP-09, Head Correction Omitted from Calibr Test Pressure,Leaving Instrument 1E22-N013 Out of Tolerance.Caused by Misunderstanding of Procedures + (ML20071G458)
- ML20071G463 + (ML20071G463)
- 05000331/LER-1983-010-03, /03L-0:on 830411,during Refueling Outage,One Snubber Found Inoperable,One Indeterminant,One Had Missing Bushing & One W/Bushing Disengaged.Caused by Procedure Error During Previous Maint + (ML20071G470)
- ML20071G486 + (ML20071G486)
- ML20071G491 + (ML20071G491)
- ML20071G496 + (ML20071G496)
- ML20071G500 + (ML20071G500)
- ML20071G501 + (ML20071G501)
- ML20071G504 + (ML20071G504)
- ML20071G507 + (ML20071G507)
- NRC-2019-0241, Declaration of Authorized Officer of Citizenss Resistance at Ferm 2 (Craft) to File as Pro Se Counsel + (ML20071G510)
- ML20071G513 + (ML20071G513)
- ML20071G515 + (ML20071G515)
- ML20071G516 + (ML20071G516)
- ML20071G517 + (ML20071G517)
- ML20071G519 + (ML20071G519)
- ML20071G522 + (ML20071G522)
- ML20071G523 + (ML20071G523)
- ML20071G526 + (ML20071G526)
- ML20071G530 + (ML20071G530)
- ML20071G534 + (ML20071G534)
- ML20071G537 + (ML20071G537)
- ML20071G542 + (ML20071G542)
- ML20071G551 + (ML20071G551)
- ML20071G564 + (ML20071G564)
- ML20071G566 + (ML20071G566)
- ML20071G570 + (ML20071G570)
- ML20071G573 + (ML20071G573)
- ML20071G587 + (ML20071G587)
- ML20071G599 + (ML20071G599)
- ML20071G606 + (ML20071G606)
- ML20071G640 + (ML20071G640)
- ML20071G643 + (ML20071G643)
- ML20071G650 + (ML20071G650)
- ML20071G654 + (ML20071G654)
- 05000254/LER-1983-017-03, /03L-0:on 830412,RHR Svc Water Pump 1-1001-65C Taken Out of Svc to Facilitate Repair of Broken Coupling on RHR Svc Water Vault Room Cooler 1-5745-C Drain Line.Caused by Overpressurization of Piping + (ML20071G657)
- 05000373/LER-1983-036-03, /03L-0:on 830414,welding Procedures Wps 1-5-A & 5-5-A Discovered in Conflict W/Asme Code.Repairs to Main Steam Drain Line Welds Made Using Subj Procedures.Evaluation of Procedures in Process + (ML20071G659)
- ML20071G660 + (ML20071G660)
- 05000254/LER-1983-018-03, /03L-0:on 830412,excessively High Discharge Pressure & Low Flow Observed from RHR Svc Water Pump 1-1001-65C.Caused by anti-rotation Pin Falling Out of Valve Operator.Pin Replaced & Screw Tightened + (ML20071G662)
- ML20071G665 + (ML20071G665)
- ML20071G667 + (ML20071G667)
- 05000285/LER-1979-015, Forwards LER 79-015/01T-0 + (ML20071G669)
- 05000285/LER-1979-015-01, /01T-0 on 790511:seismic Support Appeared Inadequate for Component Cooling Water piping-to-containment Cooling & Filtering Unit VA-3A.Analyses Indicated That Clamping piping-to-cooling Unit Will Provide Needed Support + (ML20071G672)
- 05000315/LER-1983-034-03, /03L-0:on 830413,pyralarm Detector Alarmed & Found Unplugged,Rendering Fire Zone 4 Detectors Inoperable.Caused by Failure to Plug in Alarm After Conduit Installation. Pyralarm Reinstalled & Sys Verified Operable + (ML20071G676)
- 05000315/LER-1983-035-03, /03L-0:on 830414,deluge Valves for Instrument Room Purge Exhaust 1-HV-CIPX-1 & Control Room Cleanup Sys 1-HV-ACRF-1 Would Not Open Upon Actuation Signal.Caused by Failure of Time Delay Circuit Boards + (ML20071G677)
- 05000301/LER-1983-006-03, /03L-0:on 830419,time Delay Setpoint of Contact from Time Delay Relay 2-TDRC/A06 & 4,160-volt Degraded Grid Voltage Relay 2-275/A06 Set Above Tech Spec Limit.Caused by Bumping or Mispositioning Time Set Knob + (ML20071G681)