Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000331/LER-1983-004-03, /03L-0:on 830208,during Surveillance Testing,Rcic motor-operated full-flow Test Valve MOV-2515 Would Not Properly Control Flow.Caused by Loose Valve Stem anti- Rotation Collar Due to Worn,Loose Set Screws + (ML20071F267)
- 05000327/LER-1983-022-03, /03L-0:on 830211,two of Four Level Switches Found Out of Tolerance.Caused by Instrument Drift & Inadequate Calibr & Testing Techniques.Switches Recalibr + (ML20071F268)
- ML20071F279 + (ML20071F279)
- ML20071F283 + (ML20071F283)
- ML20071F284 + (ML20071F284)
- ML20071F287 + (ML20071F287)
- 05000362/LER-1983-008-03, /03L-0:on 830123,while in Mode 3,Channel a Level Indicator 3LI-1113-1 for Steam Generator E-089 Declared Inoperable When Indicator Failed Tech Spec Surveillance. Caused by Instrument Drift.Indicator Recalibr + (ML20071F291)
- ML20071F292 + (ML20071F292)
- 05000368/LER-1983-007, Forwards LER 83-007/03L-0 + (ML20071F294)
- 05000366/LER-1979-048, Forwards Updated LER 79-048/03X-1 + (ML20071F297)
- ML20071F298 + (ML20071F298)
- PLA-1507, Forwards Monthly Operating Rept for Jan 1983 + (ML20071F304)
- ML20071F306 + (ML20071F306)
- ML20071F307 + (ML20071F307)
- ML20071F311 + (ML20071F311)
- ML20071F319 + (ML20071F319)
- ML20071F327 + (ML20071F327)
- ML20071F329 + (ML20071F329)
- ML20071F338 + (ML20071F338)
- 05000366/LER-1979-048-03, At 86% Power,Average Drywell Temp Discovered at 135.3 F.High Temp Caused by Control Rod Drive Access to Underside of Vessel Through Biological Shield Left Off During Drywell Closeout + (ML20071F342)
- ML20071F347 + (ML20071F347)
- ML20071F362 + (ML20071F362)
- ML20071F365 + (ML20071F365)
- NRC-83-0014, Forwards Rev 11 to Snupps FSAR + (ML20071F369)
- ML20071F371 + (ML20071F371)
- ML20071F374 + (ML20071F374)
- ML20071F377 + (ML20071F377)
- ML20071F379 + (ML20071F379)
- ML20071F390 + (ML20071F390)
- ML20071F404 + (ML20071F404)
- ML20071F405 + (ML20071F405)
- NRC-20-0017, Property Insurance Coverage + (ML20071F408)
- 05000285/LER-1978-030, Forwards LER 78-030/01T-0 + (ML20071F410)
- ML20071F411 + (ML20071F411)
- 05000333/LER-1978-079, Forwards LER 78-079/04L-0 + (ML20071F417)
- 05000333/LER-1978-079-04, /04L-0 on 780914:An Apparent Excessive Solute Release from Makeup Water Treatment Waste Neutralizer Tanks to Circulating Water Discharge Tunnel Was Detected While Performing Aug 78 24-hour Complete Sample Analysis + (ML20071F424)
- ML20071F428 + (ML20071F428)
- ML20071F433 + (ML20071F433)
- ML20071F434 + (ML20071F434)
- ML20071F438 + (ML20071F438)
- ML20071F444 + (ML20071F444)
- ML20071F445 + (ML20071F445)
- ML20071F446 + (ML20071F446)
- ML20071F450 + (ML20071F450)
- STC-20-023, Notification of Major Revision to Inspection Manual Chapter (IMC) 2800, Materials Inspection Program and Cancellation of IMC 1220, Processing of NRC Form 241, Report of Proposed Activities in Non-Agreement States, Areas of Exclus + (ML20071F453)
- ML20071F459 + (ML20071F459)
- ML20071F461 + (ML20071F461)
- 05000285/LER-1978-028, Forwards LER 78-028/03L-0 + (ML20071F462)
- ML20071F466 + (ML20071F466)
- 05000285/LER-1978-028-03, /03L-0 on 780831:failure of Tri-x Weather Towers 100 Meter Delta-T Sensor Sys to Rept Stability Class Info. Calibrations Revised to Ensure Instruments Detect Subsequent Sensor Sys Failures + (ML20071F467)
- ML20071F469 + (ML20071F469)