- 05000259/LER-1990-018-02, :on 901211,Security Micro Access Computer MAC-540 Malfunctioned & Automatically Shut in Degraded Mode. Nine Firewatch Observations Performed Late Due to Locking Vital Area Doors.Caused by Personnel Error + (ML20066D564)
- BSEP-91-0020, Special Rept 1-SR-90-005:on 901130,Zone 1 of Svc Water Bldg Fire Detection Sys Declared Inoperable Due to Spurious Alarms on Main Control Room Annunicator.Caused by Defective Pull Station.Fire Detection Panel Replaced + (ML20066D567)
- 05000259/LER-1990-019-02, :on 901212,hourly Fire Watch Not Established When Instrument & Control Bus 1A Tripped,Resulting in Loss of Power to Fire Detection Panels.Investigation Underway. Supplemental Rept Will Be Submitted by 910214 + (ML20066D571)
- ML20066D575 + (ML20066D575)
- AECM-82-539, Submits Confirmation That Safety Classification & Qualification of Instrumentation in FSAR Table 7.5-1 Consistent W/Nrc 811120 Memo Re Std Definitions for Commonly Used Safety Classification Terms + (ML20066D577)
- ML20066D587 + (ML20066D587)
- 05000322/LER-1990-009, :on 901211,automatic Initiation of ESF Sys Occurred When RPS Bus a Deenergized Due to Electrical Protection Assembly Breaker Trip.Caused by Low Output Voltage on RPS MG Set A.Procedure & Worksheet Revised + (ML20066D588)
- 05000322/LER-1990-010, :on 901213,unplanned ESF Actuation Occurred in Control Room Air Conditioning & RB Standby Ventilation Sys B.Caused by Procedural Deficiency.Procedure Revised,Incident Rept Issued & Policy Established + (ML20066D593)
- ML20066D598 + (ML20066D598)
- ML20066D607 + (ML20066D607)
- ML20066D608 + (ML20066D608)
- 05000424/LER-1990-022-01, :on 901212,auditor Found Possible Discrepancy in Calculation for Determining Filter Unit Electrical Heater Power Dissipation.Caused by Architect/Engineer.Request for Tech Spec Change Submitted + (ML20066D612)
- RBG-34290, Special Rept:On 901201,loose Parts Monitoring Channel 8 Detector Module Illuminated,Indicating Channel Low Background Noise.Caused by Fault within Cable.Failed Portion of Channel Will Be Repaired or Replaced + (ML20066D615)
- ML20066D616 + (ML20066D616)
- 2CAN019104, Application for Amend to License NPF-6,revising Basis for Tech Spec 3.8 Re Electrical Power Sys.Change Clarifies Emergency Diesel Generator Trips to Avoid Misinterpretation of Spec,Per Requirements of Reg Guide 1.108 + (ML20066D617)
- ML20066D623 + (ML20066D623)
- ML20066D628 + (ML20066D628)
- ML20066D630 + (ML20066D630)
- 05000313/LER-1990-020-02, :on 901030,potential for Structural Damage or Failure of Containment Polar Crane During Design Basis Conditions Discovered.Caused by Oversight of A/E During Const.Design Modified + (ML20066D633)
- ML20066D636 + (ML20066D636)
- ML20066D640 + (ML20066D640)
- ML20066D643 + (ML20066D643)
- PY-CEI-NRR-1290, Forwards Change to Rev 15 to Security Plan.Change Withheld (Ref 10CFR73.21) + (ML20066D644)
- ML20066D647 + (ML20066D647)
- ML20066D650 + (ML20066D650)
- ML20066D654 + (ML20066D654)
- ELV-02387, Responds to Violations Noted in Insp Repts 50-424/90-28 & 50-425/90-28 on 901027-1123.Corrective Actions:Technicians Counseled,Procedures Revised & Training Will Be Conducted + (ML20066D657)
- ML20066D671 + (ML20066D671)
- ML20066D674 + (ML20066D674)
- ML20066D686 + (ML20066D686)
- ML20066D693 + (ML20066D693)
- ML20066D708 + (ML20066D708)
- ML20066D712 + (ML20066D712)
- 05000445/LER-1990-044, :on 901130,reactor Operator Performed Test on Wrong Train of Charging Sys Due to Procedural Inadequacy. Results for Previously Performed Tests & Enhancements of Test Info on Work Orders Reviewed + (ML20066D714)
- 05000413/LER-1990-031-01, :on 901208,Tech Specs Violated Due to Exceeding 24 H Surveillance Interval for CNOAMP5000.Caused by Mgt Deficiency.Frequency of Daily Tech Spec Re Surveillances Changed to Once Per Shift + (ML20066D715)
- ML20066D717 + (ML20066D717)
- ML20066D720 + (ML20066D720)
- ML20066D722 + (ML20066D722)
- ML20066D723 + (ML20066D723)
- 05000382/LER-1990-019-02, :on 901212,Tech Spec LCO 3.0.3 Entered When Both Trains of Control Room HVAC Sys Declared Inoperable Due to Breach in Control Room Envelope.Caused by Insufficient Documentation & Details of Boundary Seals + (ML20066D725)
- ML20066D730 + (ML20066D730)
- ML20066D733 + (ML20066D733)
- B13701, Responds to NRC 901108 Request for Addl Info Re 900809 Application for Amend to License DPR-65,proposing Rev to Tech Specs 3.0.4,4.0.3 & 4.0.4 & Bases Sections Associated W/Specs 3.0 & 4.0 in Accordance W/Generic Ltr 87-09 + (ML20066D735)
- ST-HL-AE-3635, Application for Amends to Licenses NPF-76 & NPF-80,changing Tech Specs by Transferring More cycle-specific Parameters Limits to Existing Core Operating Limits Rept + (ML20066D737)