- 05000316/LER-1982-035-03, /03L-0:on 820413,flow Path from Boric Acid Transfer Pumps to Charging Pump Suction Isolated to Enable Repairs on Flow Instrument Isolation Valve Cs-486.Valve Leak Caused by Diaphragm Failure.Diaphragm Replaced + (ML20052J020)
- ML20052J021 + (ML20052J021)
- ML20052J022 + (ML20052J022)
- ML20052J023 + (ML20052J023)
- 05000316/LER-1982-036-03, /03L-0:on 820422,flow Path from Bast to RCS Isolated in Order to Unplug Bast Recirculation Line.Caused by Repair to Boric Acid Recirculation Line Due to Pluggage. Line Unplugged & Flow Path Restored + (ML20052J024)
- ML20052J025 + (ML20052J025)
- ML20052J027 + (ML20052J027)
- 05000316/LER-1982-037-03, /03L-0:on 820423,while Establishing Clearance to Repair Valve,Flow Path from Boric Acid Tanks to Charging Pumps Suction Removed from Svc.Caused by Failed Diaphragm on Filter Isolation Valve.New Diaphragm Installed + (ML20052J028)
- ML20052J029 + (ML20052J029)
- ML20052J030 + (ML20052J030)
- ML20052J031 + (ML20052J031)
- ML20052J032 + (ML20052J032)
- ML20052J033 + (ML20052J033)
- 05000318/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20052J035)
- 05000245/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl + (ML20052J037)
- ML20052J039 + (ML20052J039)
- ML20052J041 + (ML20052J041)
- 05000318/LER-1982-018-03, /03L-0:on 820417,control Element Assembly 21 Dropped Into Core After Electricians Inadvertently Disconnected Power,Resulting in Pressurizer Level Deviation Exceeding Tech Spec Limit.Caused by Personnel Error + (ML20052J042)
- 05000245/LER-1982-009-03, /03L-0:on 820412,while Performing High Pressure Scram & Containment Isolation Functional Calibr Test, Pressure Switch 2206-1612D Failed to Trip at Desired Setpoint.Caused by Setpoint Drift.Switch Replaced + (ML20052J043)
- ML20052J046 + (ML20052J046)
- ML20052J048 + (ML20052J048)
- IR 05000089/1982001 + (ML20052J052)
- ML20052J054 + (ML20052J054)
- 05000285/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20052J057)
- 05000285/LER-1982-009-03, /03L-0:on 820411,while Exchanging Component Cooling Water Heat Exchangers,Associated Outlet Valves HCV-490B,HCV-491B & HCV-492B Failed to Open.Cause Not stated.HCV-491B Reassembled & Tested + (ML20052J063)
- ML20052J068 + (ML20052J068)
- ML20052J069 + (ML20052J069)
- ML20052J073 + (ML20052J073)
- ML20052J076 + (ML20052J076)
- ML20052J077 + (ML20052J077)
- IR 05000312/1982016 + (ML20053A000)
- ML20053A003 + (ML20053A003)
- ML20053A004 + (ML20053A004)
- IR 05000312/1982013 + (ML20053A007)
- ML20053A008 + (ML20053A008)
- ML20053A009 + (ML20053A009)
- 05000364/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20053A013)
- 05000327/LER-1981-071, Forwards LER 81-071/03L-0 + (ML20053A015)
- ML20053A017 + (ML20053A017)
- ML20053A019 + (ML20053A019)
- 05000327/LER-1981-071-03, /03L-0:on 810617,charcoal Test Canister on Train B Main Control Room Emergency Ventilation Sys Failed to Meet Acceptance Criteria of 99% Methyl Iodine Removal Efficiency. Probably Caused by Age & Weathering of Charcoal + (ML20053A021)
- 05000364/LER-1981-039-03, /03L-0:on 810915,while Performing FNP-2-STP-20.0A, a Train Penetration Room Filtration Sys Declared Inoperable When Pressure Differential Transmitter Failed to Open for Damper.Caused by Transmitter Drift.Unit Recalibr + (ML20053A022)
- ML20053A023 + (ML20053A023)
- ML20053A024 + (ML20053A024)
- ML20053A027 + (ML20053A027)
- ML20053A028 + (ML20053A028)
- ML20053A030 + (ML20053A030)
- ML20053A033 + (ML20053A033)
- ML20053A035 + (ML20053A035)
- 05000309/LER-1982-002, Forwards LER 82-002/01T-0 + (ML20053A037)
- 05000327/LER-1981-066, Forwards LER 81-066/03L-0 + (ML20053A039)