Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20049A734 + (ML20049A734)
- ML20049A737 + (ML20049A737)
- 05000272/LER-1981-082, Forwards LER 81-082/03L-0.Detailed Event Analysis Encl + (ML20049A738)
- ML20049A740 + (ML20049A740)
- 05000272/LER-1981-082-03, /03L-0:on 810827,insulation Found Off Duct Outside Primary Sample Room Forming Penetration Barrier.Continuous Fire Watch Established.Insulation Reinstalled + (ML20049A742)
- 05000309/LER-1981-020, Forwards LER 81-020/03L-0 + (ML20049A743)
- ML20049A745 + (ML20049A745)
- 05000309/LER-1981-020-03, /03L-0:on 810922,during Review of Outstanding Procedure Change Repts,One Procedure Found Not Reviewed within 14 Days of Being Generated as Required by Tech Spec. Caused by Personnel Oversight.Personnel Counseled + (ML20049A746)
- ML20049A747 + (ML20049A747)
- 05000321/LER-1981-098, Forwards LER 81-098/03L-0 + (ML20049A748)
- ML20049A750 + (ML20049A750)
- 05000321/LER-1981-098-03, /03L-0:on 810814,while Operating at 243 MW,4-hr Surveillance Test on Primary Coolant Was Not Performed,Per Tech Spec 4.6.F.1.c.Caused by Oversight.Turnover Sheet Will Be Carefully Reviewed + (ML20049A751)
- PNO-I-81-107, on 810923,truck Carrying 6 Packages Containing Spent Mo-99/Tc-99m Generators,Crashed & Burned Near Swiftwater,Pa.Only Cab Burned & Packages Not Involved.No Excessive Radiation or Contamination Levels Identified + (ML20049A752)
- ML20049A753 + (ML20049A753)
- 05000311/LER-1981-093, Forwards LER 81-093/03L-0.Detailed Event Analysis Encl + (ML20049A754)
- ML20049A756 + (ML20049A756)
- 05000311/LER-1981-093-03, /03L-0:on 810825,auxiliary Alarm Annunciator Failed Causing Containment Sump Level Monitoring Sys to Be Declared Inoperable.Caused by Failure of Integrated Circuit Chips.Circuit Chips Replaced + (ML20049A757)
- ML20049A758 + (ML20049A758)
- ML20049A759 + (ML20049A759)
- ML20049A760 + (ML20049A760)
- ML20049A761 + (ML20049A761)
- ML20049A763 + (ML20049A763)
- FVY-81-142, Responds to NRC 810729 Request for Commitment to Implement Mods Re Unresolved Safety Issue A-10 on BWR Nozzle Cracking. Extension Requested Until 811016 to Clarify Responses + (ML20049A764)
- ML20049A766 + (ML20049A766)
- ML20049A767 + (ML20049A767)
- ML20049A769 + (ML20049A769)
- ML20049A772 + (ML20049A772)
- AECM-81-367, Final Deficiency Rept Re Failure of Pillow Block Bearings in Standby Svc Water Basin Fans,Initially Reported on 800826. Bearings Replaced,Remote Lubrication Line Added for Accessibility & Maint Procedures Being Upgraded + (ML20049A774)
- ML20049A776 + (ML20049A776)
- 05000366/LER-1981-086, Forwards LER 81-086/03L-0 + (ML20049A777)
- ML20049A778 + (ML20049A778)
- ML20049A781 + (ML20049A781)
- ML20049A782 + (ML20049A782)
- ML20049A783 + (ML20049A783)
- ML20049A784 + (ML20049A784)
- 05000366/LER-1981-086-03, /03L-0:on 810904,w/plant Increasing Power,Hpci Turbine Exhaust Pressure Switch 2E41-N017B Failed,Tripping HPCI Turbine.Hpci Declared Inoperable.Caused by Shorted micro-switch.Switch Replaced & Recalibr + (ML20049A787)
- ML20049A788 + (ML20049A788)
- 05000247/LER-1981-020, Forwards LER 81-020/03L-0 + (ML20049A789)
- ML20049A791 + (ML20049A791)
- 05000304/LER-1981-019, Forwards LER 81-019/03L-0 + (ML20049A792)
- ML20049A796 + (ML20049A796)
- 05000321/LER-1981-092, Forwards LER 81-092/03L-0 + (ML20049A799)
- ML20049A804 + (ML20049A804)
- 05000247/LER-1981-020-03, /03L-0:on 810821,during Normal Operation,Control Rod G-3 Dropped Into Core,Initiating Turbine Runback.Caused by Spray from Leaking Plug Needle Valve on Control Rod H-2, Causing Coil Stack Connector to Fault.Connector Repaire + (ML20049A807)
- ML20049A808 + (ML20049A808)
- 05000304/LER-1981-019-03, /03L-0:on 810825,during Normal Operation,Steam Generator Level X Meter 2LT-537 Found to Be High.Caused by Zero Shift.Transmitter Calibr & Returned to Svc + (ML20049A809)
- 05000321/LER-1981-092-03, /03L-0:on 810828,during Steady State Operation, Noble Gas Fission Product Monitor Found Inoperable.Caused by Component Failure.Defective Components Replaced + (ML20049A810)
- ML20049A811 + (ML20049A811)
- 05000336/LER-1981-031, Forwards LER 81-031/03L-0 + (ML20049A813)
- ML20049A815 + (ML20049A815)
- 05000336/LER-1981-031-03, /03L-0:on 810825,during Testing,Diesel Generator 12U Failed to Start on Signal.Apparently Caused by Loose Amphenol Connector Between Emergency Generator Control & Woodward Governor.Connector Cleaned & Tightened + (ML20049A816)