- ML20042F401 + (ML20042F401)
- ML20042F405 + (ML20042F405)
- ML20042F406 + (ML20042F406)
- ML20042F407 + (ML20042F407)
- ML20042F408 + (ML20042F408)
- ML20042F409 + (ML20042F409)
- 05000461/LER-1990-007, :on 900331,inadequate Determination of Equipment Status Resulted in de-energization of Nuclear Sys Protection Sys.Caused by Personnel Error.Fact Sheet on Operation Issued & Personnel Retrained + (ML20042F411)
- ML20042F412 + (ML20042F412)
- ML20042F416 + (ML20042F416)
- ML20042F418 + (ML20042F418)
- ML20042F419 + (ML20042F419)
- ML20042F420 + (ML20042F420)
- ML20042F422 + (ML20042F422)
- ML20042F423 + (ML20042F423)
- ML20042F424 + (ML20042F424)
- ML20042F428 + (ML20042F428)
- ML20042F429 + (ML20042F429)
- AECM-90-0040, Application for Amend to License NPF-29,clarifying Name Used to Describe Plant Location in Which Equipment Area Temp & Equipment Area Delta Temp Isolation Actuation Instrumentation Installed for RWCU + (ML20042F433)
- ML20042F435 + (ML20042F435)
- ML20042F436 + (ML20042F436)
- 0CAN059007, Requests 90-day Extension to Provide Addl Time for Reviews of Amends 128 & 102 to Licenses DPR-51 & NPF-6,respectively, Re Ownership Transfer + (ML20042F437)
- ML20042F438 + (ML20042F438)
- AECM-90-0067, Forwards Response to Generic Ltr 89-19 Re USI A-47, Safety Implications of Control Sys in LWR Nuclear Power Plants. Plant Has Adequate Automatic Reactor Vessel Overfill Protection,Procedures & Tech Specs + (ML20042F444)
- ML20042F448 + (ML20042F448)
- ML20042F454 + (ML20042F454)
- ML20042F456 + (ML20042F456)
- B13455, Requests Addl Relief Requests from ASME Code Section XI Requirements for Second 10-yr Insp Interval.Relief Request Should Be Acted Upon Prior to 1991 Refueling Outage in Order to Avoid Unnecessary Valve Disassembly + (ML20042F458)
- ML20042F459 + (ML20042F459)
- ML20042F461 + (ML20042F461)
- ML20042F462 + (ML20042F462)
- AECM-90-0003, Application for Amend to License NPF-29,revising Footnotes & Action Statements to Enforce Administrative Controls on Handling of Loads Over Irradiated Fuel W/O Secondary Containment Integrity + (ML20042F463)
- ML20042F465 + (ML20042F465)
- ML20042F469 + (ML20042F469)
- ML20042F470 + (ML20042F470)
- 05000413/LER-1990-015, :on 900402,Tech Spec 3.0.3 Entered When Both Trains of Containment Valve Injection Water Sys Rendered Inoperable.Caused by Supervisor Incorrectly Denoting Valve Position.Valves 1RN-493 & 494 Closed + (ML20042F472)
- 05000458/LER-1990-012, :on 900401,ESF Actuations Occurred Due to Electrical Protection Assembly Breakers Trip.Caused by Voltage Regulator Failure.Replacement Voltage Regulator Card Installed in MG 1C71-S001B + (ML20042F473)
- 05000414/LER-1990-006, :on 900321,discovered That Nuclear Svc Water Sys Assured Makeup Source to Containment Valve Injection Water Sys Surge Chamber 2A Would Not Provide Adequate Flow. Caused by Clogged Pipe + (ML20042F474)
- ML20042F476 + (ML20042F476)
- ML20042F477 + (ML20042F477)
- ML20042F478 + (ML20042F478)
- ML20042F481 + (ML20042F481)
- ML20042F483 + (ML20042F483)
- ML20042F484 + (ML20042F484)
- IR 05000206/1990007 + (ML20042F485)
- ML20042F487 + (ML20042F487)
- ML20042F488 + (ML20042F488)
- AECM-90-0086, Requests Extension of 90 Days to Provide Addl Time for Securities & Exchange Commission Review Re Implementation of Amend 65 to License NPF-29 + (ML20042F489)
- ML20042F490 + (ML20042F490)
- PY-CEI-NRR-1171, Forwards Response to Generic Ltr 89-19 Re Reactor Vessel Overfill Protection + (ML20042F493)
- ML20042F500 + (ML20042F500)
- ML20042F502 + (ML20042F502)