Dear Chairman Carr:

SUBJECT:

CRITIQUE OF THE ENVIRONMENTAL ~ PROTECTION AGENCY'S i

STANDARDS FOR DISPOSAL OF'HIGH-LEVEL' WASTES In response to your request during our meeting on February :21, 1990, the Advisory Committee on Nuclear Waste offers the-following comments on the problems we see with the EPA standards (Ref.1) for the disposal of high-level wastes. These comments are an outgrowth of our ongoing review of these standards, including a full-day session on this matter during our 18th meeting, March 22-23, 1990, and additional discussions during our 19th meeting, April 26-27, 1990.

Organizations whose representatives.took part'in'the dis-cussions during.our 18th meeting included the ~ Environmental 3

Protection Agency, the Nuclear Waste Technical' Review Board,Ethe staff'of the Board on Radioactive. Waste Management of the National Academy of Sciences, the Environmental Evaluation Group of the a

State of New Mexico, the Advisory Committee on Nuclear. Facility Safety of the U.S. Department of Energy, and the General Accounting Office.

Members of.the NRC staff also attended these meetings.

l Key technical problems with the EPA. standards include the i

following:

l 1.

All such standards should be organized in. a hierarchical structure with the higher levels-expressing the. objectives in a

qualitative sense and the lower levels-stating ~ the objectives quantitatively.

Of utmost importance is that the several levels be consistent and that lower. levels not be more stringent or conservative than the higher levels, so that they become de facto new standards.

This is not the case with the i

. EPA standards.

o 9005080301 900501 PDR ADVCM NACNUCLE hi R-OO34 PDC

,y..-

.a 1

~

The Honorable Kenneth M. Carr 2

May 1,1990

-2.

Although lower level standards can be _ stated probabilis-tically, they should be expressed-in terms of annual risk limits from a disposal f acility ' in - an undisturbed and a

--disturbed state.-

The critical-population group being considered should be clearly defined.

This approach is.in accord ' with recommendations of organizations such as the International Commission on Radiological Protection and the l-United Kingdom's National. Radiological Protection Board.

1

(

3.

The standards should apply to the disposal facility as a l

system.

Subsystem standards, if expressed, should be given-only as

guidance, with qualifying statements clearly l_

specifying that they are not to be applied-in a regulatory sense.

i 4.

Evaluations of the anticipated performance of.the proposed Waste Isolation Pilot Plant indicate _that, for the disturbed state, human intrusion is the dominant contributor to risk.

Early indications suggested that p'erformance analyses for the proposed Yucca Mountain repository may also show human intrusion to be important.- This appears to be a direct result of how the standards for.. evaluating such intrusions are interpreted, compounded by the overly conservative require-ments of the standards.

To ameliorate this issue, we suggest that the standards be rewritten to separate the evaluations l

of anticipated performance 'into three parts:

(a) the l

undisturbed repository; (b) the disturbed repository, exclusive of human-intrusion; and '(c) the repository as it i

might be affected by human intrusion.

This would - clearly separate out the problem of human intrusion and permit-it to be addressed directly.

In this regard, we join with the Advisory Committee on' Nuclear Facility Safety,. U.S. Department of Energy, in recommending that EPA's standards be reworded to permit " considerations such. as expectations.~for future borehole sealing at least as good as the current state-of-the-art."

We also believe that more realistic assessments should be made of the potential impacts of. human intrusions and that greater credit should be allocated to the ability of future generations to be aware of the presence of a geologic repository through identifying markers and associated records.

5.

Experience has shown that probabilistic risk analyses cannot be used reliably to determine the compliance of a single l

nuclear power plant with a set of standards.

A high-level waste repository, which must function for 10,000 years, is still more difficult - to assess quantitatively.

The EPA standards should clearly specify that risk assessments are but one of several inputs into the evaluation of a given high-level waste repository site and/or facility. Such assessments should-not be the only factor in evaluating compliance of such a facility with the EPA standards.

t

^ The: Honorable Kenneth M.

Carr 3

May 1, 1990

-In summary, our key recommendations are:

1.

The existing EPA standards need'to be revised; now is the time to accomplish this task; 2.

The standards should be revised _ to define what is-considered to be an acceptable risk from'a high-level waste repository;-

i 3.

The standards should specify that -a probabilistic approach. is acceptable so long as it..is but one of several factors to.

be used in determining: 'the acceptability of a specific site;'and 4.

The standards should be revised to include separate considerations for evaluating the impacts of - human intrusion.

I

'We stand ready to join'you and the NRC staff in_ working with EPA-

~~ ~~

to help develop.an acceptable set of standards for a high-level radioactive waste repository.

We believe this is'the best course of action at.the present time.

If,'however, after a reasonable-period of time these efforts do not appear to.be accomplishing our mutual goals, we believe other approaches should be considered.

t L

One would be for you, as Chairman of the NRC (perhaps joining with the Secretary. of DOE) to approach the -EPA ' Administrator with a

. suggestion that an appropriate organization be selected to review t

the standards.and make recommendations for change. Suggestions for two such organizations are the National Academy of Sciences' and the a

Council on Environmental Quality.

l We hope that these comments are helpful..

We will~be pleased-to discuss these matters-with you at your convenience.

Sincerely,,

Dade W. Moeller Chairman l

References:

1.

U.S. Environmental Protection Agency, " Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes,"

(40 CFR Part 191), Working Draft 2, dated January 31, 1990

1 The Honorable Kenneth M. Carr 4

May 1,-1990 2.

Letter dated April?l7, 1990 from F.

L..Galpin, Environmental Protection Agencysto Dade W. Moeller 3.

Letter dated December 11, 1989 from John F. Ahearne, Advisory Committee on Nuclear Facility Safety,

DOE, to ' James D.

Watkins,< Secretary of Energy, DOE 4.-

Sandia National Laboratories, SAND 89-2027,

" Performance Assessment Methodology Demonstration:' Methodology Development for Evaluating Compliance With EPA 40 CFR 191, Subpart B, for the-Waste Isolation-Pilot Plant," Printed December 1989 5.

International Commission on Radiological' Protection,-

?RP Publication 46,

" Radiation Protection ' Principles for che Disposal of Solid Radioactive. Waste," published for the-International Commission on Radiological Protection by Pergamon Press, Oxford, England, July 1985 6.

National Radiological-Protection Board, NRPB-GS 1,

" Radio-r logical Protection Objectives for the Disposal. of Solid Radioactive Wastes," published in Oxfordshire, England, 1983 t

1 o

(