Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20041F860 + (ML20041F860)
- 05000269/LER-1982-001-03, /03L-0:on 820203,motor Driven Emergency Feedwater Pump 1B Declared Inoperable Due to Bearing Vibration Exceeding Acceptable Limits.Caused by Misalignment Between Pump & Motor.Pump & Motor Realigned & Tested Satisfactorily + (ML20041F861)
- 05000320/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20041F862)
- 05000325/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20041F864)
- ML20041F866 + (ML20041F866)
- 05000327/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20041F867)
- ML20041F869 + (ML20041F869)
- ML20041F871 + (ML20041F871)
- 05000325/LER-1982-006-03, /03L-0:on 820205,during Secondary Containment Integrity Verification,Flow Rate Could Not Be Achieved within Tech Specs Limit.Caused by Failure to Maintain Greater than 25-inch Vacuum Due to Penetration Air Leaks + (ML20041F872)
- 05000320/LER-1982-009-03, /03L-0:on 820201,auxiliary Bldg Ventilation Sys Declared Inoperable Due to Low Exhaust Flowrate.Caused by Failure to Readjust Flowrate to Be Greater than 65,000 Cfm Flowrate Limit.Exhaust Fan Vortex Dampers Adjusted + (ML20041F873)
- 05000327/LER-1982-018-03, /03L-0:on 820207,during Startup,Containment Lower Compartment Average Air Temp Discovered at 124.19 F.Two Lower Compartment Train a Coolers Temp Control Valves Had Wrong Settings.Cause Unknown + (ML20041F874)
- ML20041F875 + (ML20041F875)
- ML20041F876 + (ML20041F876)
- ML20041F878 + (ML20041F878)
- 05000296/LER-1982-004, Forwards LER 82-004/03L-0 + (ML20041F879)
- ML20041F881 + (ML20041F881)
- 05000296/LER-1982-004-03, /03L-0:on 820207,while Performing Surveillance Instruction,Temp Switches 3S-TS-73-2A & 3-TS-73-2B Operated Above Tech Specs Limit.Caused by Switches Being Out of Calibr.Switches Calibr + (ML20041F883)
- IR 05000324/1981025 + (ML20041F884)
- ML20041F886 + (ML20041F886)
- ML20041F887 + (ML20041F887)
- ML20041F888 + (ML20041F888)
- ML20041F890 + (ML20041F890)
- ML20041F891 + (ML20041F891)
- ML20041F892 + (ML20041F892)
- ML20041F893 + (ML20041F893)
- ML20041F894 + (ML20041F894)
- ML20041F895 + (ML20041F895)
- 05000280/LER-1982-005-03, /03L-0:on 820207,trip Valve TV-SS-204B Was Discovered Open & Would Not Close W/O Operator Intervention. Caused by Misalignment of Actuation Disk.Actuation Disk Adjusted + (ML20041F896)
- ML20041F899 + (ML20041F899)
- IR 05000338/1981029 + (ML20041F900)
- 05000280/LER-1982-020-03, /03L-0:on 820205,w/unit at 100% Power,Loss of Boric Acid Flow to Blender Was Observed.Caused by Operating Mechanism Failure on Valve 1-CH-88.Valve Mechanism Repaired + (ML20041F901)
- ML20041F902 + (ML20041F902)
- ML20041F903 + (ML20041F903)
- 05000318/LER-1982-002-03, /03L-0:on 820204,during Surveillance Testing,, Feeder Breaker 152-2101 Tripped Open Causing Loss of Power to 21-4 Kv Bus.Caused by Failed Isolator Module.Isolator Replaced & Sys Tested Satisfactorily + (ML20041F905)
- PNO-II-82-025, on 820304,TVA Board of Directors Voted to Defer Const Indefinitely.Board Authorized Util Staff to Analyze Feasibility of Converting Units to coal-fired Plants + (ML20041F906)
- ML20041F907 + (ML20041F907)
- ML20041F908 + (ML20041F908)
- PNO-II-82-024A, on 820302,thermal Sleeve on One of Two Makeup Lines Found Slightly Out of Place.Caused by Absence of Four Restraining Button Welds.Thermal Sleeve Will Be Replaced & Button Welds Refabricated + (ML20041F909)
- ML20041F910 + (ML20041F910)
- PNO-II-81-088, on 811016,subcontractor Employee Received Third Degree Burns,During Welding Operations,On Both Hands & Right Leg While Working on Steam Generator.Employee Transferred to Local Hosp + (ML20041F911)
- ML20041F912 + (ML20041F912)
- ML20041F913 + (ML20041F913)
- ML20041F914 + (ML20041F914)
- ML20041F916 + (ML20041F916)
- ML20041F917 + (ML20041F917)
- 05000280/LER-1982-029, Forwards LER 82-029/01T-0 + (ML20041F918)
- 05000271/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20041F920)
- ML20041F922 + (ML20041F922)
- ML20041F923 + (ML20041F923)
- ML20041F924 + (ML20041F924)
- ML20041F925 + (ML20041F925)