- ML20038C699 + (ML20038C699)
- 05000281/LER-1981-071-03, /03L-0:on 811107,setpoints of 2 Main Steam Safety Valves Not within Plus or Minus 3% of Required Value.Caused by Normal Setpoint Drift.Setpoints Adjusted + (ML20038C700)
- ML20038C702 + (ML20038C702)
- 05000244/LER-1981-016, Forwards LER 81-016/03L-0 + (ML20038C703)
- 05000259/LER-1981-075, Forwards LER 81-075/03L-0 + (ML20038C705)
- 05000281/LER-1981-076-03, /03L-0:on 811108,recirculation Spray Heat Exchangers Svc Water Valve MOV-SW-203C Failed in Intermediate Position.Cause Not Determined.Valve Inspected Mechanically & Electrically + (ML20038C708)
- ML20038C709 + (ML20038C709)
- AECM-81-476, Final Deficiency Rept Re Failure of Control Rod Drive Hydraulic Sys Scram Pilot Valves,Initially Reported 810826. Also Reportable Under Part 21.Scram Pilot Valves Are Being Rebuilt to Replace Damaged Parts + (ML20038C710)
- ML20038C711 + (ML20038C711)
- PNO-I-81-128A, coordination Meeting Planned for 811214 W/Doe to Discuss Higher than Background Radiation Levels Noted in Eg&G 810525 Aerial Survey & 811123 Ground Survey at WR Grace & Co Extraction Site + (ML20038C713)
- 05000244/LER-1981-016-03, /03L-0:on 811105,during Test C,Si Pump Did Not Start W/Bus 16 Breaker.Caused by Closing Circuit Malfunction,Due to Weak Lockout Coil.Qualified Replacement Installed & Tested + (ML20038C714)
- ML20038C715 + (ML20038C715)
- ML20038C716 + (ML20038C716)
- 05000334/LER-1981-098, Forwards LER 81-098/03L-0 + (ML20038C717)
- PNO-I-81-129, licensee Urinalysis Results Indicate That Employee Involved in Grinding Operations in Apr 1981 May Have Received Overexposure + (ML20038C719)
- 05000261/LER-1981-025, Forwards LER 81-025/03L-0 + (ML20038C720)
- ML20038C722 + (ML20038C722)
- ML20038C724 + (ML20038C724)
- ML20038C725 + (ML20038C725)
- ML20038C727 + (ML20038C727)
- 05000261/LER-1981-025-03, /03L-0:on 811102,emergency Diesel Generator B Failed to Start Manually.Caused by Loss of Prime in Fuel Oil Sys,Possibly Due to Debris in Ball Check Valve.Generator Returned to Svc + (ML20038C728)
- 05000334/LER-1981-098-03, /03L-0:on 811107,w/reactor at 92%,technicians Performing 1B H2 Analyzer Maint Surveillance Procedure Reported Smoke Originating from H2 Analyzer Cabinet.Caused by Electrical Short within Wiring Harness.Short Repaired + (ML20038C729)
- ML20038C730 + (ML20038C730)
- ML20038C731 + (ML20038C731)
- 05000321/LER-1981-116, Forwards LER 81-116/03L-0 + (ML20038C732)
- ML20038C734 + (ML20038C734)
- ML20038C735 + (ML20038C735)
- ML20038C736 + (ML20038C736)
- ML20038C737 + (ML20038C737)
- ML20038C738 + (ML20038C738)
- ML20038C739 + (ML20038C739)
- 05000321/LER-1981-116-03, /03L-0:on 811111 W/Unit in Fuel Reconstitution Outage,Intermediate Range Monitors Functional Test Was Performed 4-h Late.Caused by Personnel Error.Procedure Performed Satisfactorily.Equipment Returned to Svc + (ML20038C741)
- ML20038C742 + (ML20038C742)
- ML20038C743 + (ML20038C743)
- ML20038C746 + (ML20038C746)
- ML20038C747 + (ML20038C747)
- IR 05000423/1981013 + (ML20038C750)
- 05000334/LER-1981-096, Forwards LER 81-096/03L-0 + (ML20038C752)
- ML20038C754 + (ML20038C754)
- ML20038C756 + (ML20038C756)
- ML20038C758 + (ML20038C758)
- 05000334/LER-1981-096-03, /03L-0:on 811030,low Temp Alarm on Boron Injection Tank Inlet Isolation Valve MOV-SI-867A Was Received Rendering One Train of Heat Trace Inoperable.Cause Not Stated.Alarm Switch Recalibr & Circuit Returned to Svc + (ML20038C761)
- ML20038C762 + (ML20038C762)
- 05000366/LER-1981-106, Forwards LER 81-106/03L-0 + (ML20038C763)
- 05000334/LER-1981-095, Forwards LER 81-095/03L-0 + (ML20038C765)
- ML20038C767 + (ML20038C767)
- ML20038C768 + (ML20038C768)
- ML20038C770 + (ML20038C770)
- 05000366/LER-1981-106-03, /03L-0:on 811108,during Reactor Startup,Filter Train 2T46-D001B Failed to Respond to Start Signal.Cause Attributed to Open Circuit on Start Logic Due to Loose Connection on Control Switch.Wire Repaired + (ML20038C772)
- ML20038C773 + (ML20038C773)
- 05000334/LER-1981-095-03, /03L-0:on 811029,dc Control Power Breaker for 1A Component Cooling Water pump,CC-P-1A,found in Off Position. Caused by Dc Charging Motor Protruding from Breaker Frame W/ Bolts at Bottom of Cubicle.All 4kV Breakers Inspected + (ML20038C775)